Isabel Abreu

Dr. Isabel Abreu

Fernando Pessoa University, Porto, Portugal
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
Ana FonsecaAna Fonseca
Ana Fonseca
Isabel AbreuIsabel Abreu
Isabel Abreu
MGMaria Guerreiro
Maria Guerreiro
Nelson Azevedo BarrosNelson Azevedo Barros
Nelson Azevedo Barros
The adequate assessment and management of indoor air quality in healthcare facilities is of utmost importance for patient safety and occupational health purposes. This study aims to identify the recent trends of research on the topic through a systematic literature review following the preferred reporting items for systematic reviews and meta-analyses (PRISMA) methodology. A total of 171 articles published in the period 2015–2020 were selected and analyzed. Results show that there is a worldwide growing research interest in this subject, dispersed in a wide variety of scientific journals. A textometric analysis using the IRaMuTeQ software revealed four clusters of topics in the sampled articles: physicochemical pollutants, design and management of infrastructures, environmental control measures, and microbiological contamination. The studies focus mainly on hospital facilities, but there is also research interest in primary care centers and dental clinics. The majority of the analyzed articles (85%) report experimental data, with the most frequently measured parameters being related to environmental quality (temperature and relative humidity), microbiological load, CO2 and particulate matter. Non-compliance with the WHO guidelines for indoor air quality is frequently reported. This study provides an overview of the recent literature on this topic, identifying promising lines of research to improve indoor air quality in healthcare facilities.

25 December 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
Ana FonsecaAna Fonseca
Ana Fonseca
Isabel AbreuIsabel Abreu
Isabel Abreu
MGMaria Guerreiro
Maria Guerreiro
CACristina Abreu
Cristina Abreu
RSRicardo Silva
Ricardo Silva
Nelson Azevedo BarrosNelson Azevedo Barros
Nelson Azevedo Barros
Adequate management of indoor air quality (IAQ) in healthcare units has relevant impacts on sustainability performance due to its effects on patient safety, occupational health and safety, and energy consumptions. This study sought to identify improvement opportunities on IAQ management by collecting and analyzing experimental data of selected parameters in three healthcare units in Portugal: Two general hospitals and one primary healthcare center. Indoor air temperature, relative humidity, CO2, bacteria, and fungi concentrations were measured in summer and winter campaigns in June/July 2017 and in January/March 2018. Results show that the exclusive use of natural ventilation is not adequate when the affluence of users is high, but the analyzed parameters revealed acceptable results under low occupation intensity conditions. Results also show that keeping low indoor air relative humidity has a significant impact in reducing fungi concentration and that there is a significant correlation at the 0.05 level between indoor air CO2 concentration and bacterial loads. Therefore, as opportunities to improve sustainability, IAQ management in healthcare facilities should consider natural ventilation as a complement to mechanical ventilation systems and should focus on adequate control of indoor air relative humidity and CO2 concentration to reduce the risk of airborne infections.

9 February 2013 in International Journal of Climatology
Verified
Journal Article
Open access
PDF file
MGMaria Guerreiro
Maria Guerreiro
EAEunice Andrade
Eunice Andrade
Isabel AbreuIsabel Abreu
Isabel Abreu
TLTeresa Lajinha
Teresa Lajinha
The state of Ceará is a semiarid region in north-eastern Brazil, having a high spatial and temporal variability of precipitation, which poses challenges for water resources management. The objective of this study is to describe and analyse the long-term variation of monthly precipitation indices and their relation to sea surface temperature (SST) anomalies. Data from 55 weather stations in the state of Ceará from 1974 to 2009 was analysed. In general, a decreasing tendency in monthly precipitation was observed over almost all the state of Ceará. The results point to a tendency for dry months to become dryer and to a decrease in precipitation intensity. SST anomalies from October to March correlate with precipitation indices from January to April, showing decreasing lag times towards the end of the wet season. The most influential SST anomalies locations are Niño 1+2, Niño 3, Niño 3.4 and Global Tropics.

1 September 2021 in Journal of Cleaner Production
Verified
Journal Article
Closed access
Ana FonsecaAna Fonseca
Ana Fonseca
Isabel AbreuIsabel Abreu
Isabel Abreu
WSWinston Jerónimo Silvestre
Winston Jerónimo Silvestre

27 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Nelson Azevedo BarrosNelson Azevedo Barros
Nelson Azevedo Barros
Pedro Miguel Alves SobralPedro Miguel Alves Sobral
Pedro Miguel Alves Sobral
Rui Silva MoreiraRui Silva Moreira
Rui Silva Moreira
JVJoao Vargas
Joao Vargas
Ana FonsecaAna Fonseca
Ana Fonseca
MGMaria Guerreiro
Maria Guerreiro
Indoor air quality (IAQ) problems in school environments are very common and have significant impacts on students’ performance, development and health. Indoor air conditions depend on the adopted ventilation practices, which in Mediterranean countries are essentially based on natural ventilation controlled through manual window opening. Citizen science projects directed to school communities are effective strategies to promote awareness and knowledge acquirement on IAQ and adequate ventilation management. Our multidisciplinary research team has developed a framework—SchoolAIR—based on low-cost sensors and a scalable IoT system architecture to support the improvement of IAQ in schools. The SchoolAIR framework is based on do-it-yourself sensors that continuously monitor air temperature, relative humidity, concentrations of carbon dioxide and particulate matter in school environments. The framework was tested in the classrooms of University Fernando Pessoa, and its deployment and proof of concept took place in a high school in the north of Portugal. The results obtained reveal that CO2 concentrations frequently exceed reference values during classes, and that higher concentrations of particulate matter in the outdoor air affect IAQ. These results highlight the importance of real-time monitoring of IAQ and outdoor air pollution levels to support decision-making in ventilation management and assure adequate IAQ. The proposed approach encourages the transfer of scientific knowledge from universities to society in a dynamic and active process of social responsibility based on a citizen science approach, promoting scientific literacy of the younger generation and enhancing healthier, resilient and sustainable indoor environments.

12 July 2023 in Healthcare
Verified
Journal Article
Open access
PDF file
JBJocélia Maria de Azevedo Bringel
Jocélia Maria de Azevedo Bringel
Isabel AbreuIsabel Abreu
Isabel Abreu
MMMARIA-CLÁUDIA MENDES CAMINHA MUNIZ
MARIA-CLÁUDIA MENDES CAMINHA MUNIZ
PAPaulo César de Almeida
Paulo César de Almeida
MSMaria-Raquel G Silva
Maria-Raquel G Silva
Excessive noise in the work environment has been associated with extra-auditory symptoms, which can have harmful long-term effects on individuals. The purpose of this study was to identify noise levels in neonatal intensive care units and investigate their impact on the occurrence of stress among healthcare professionals, using cortisol levels as a biomarker for Burnout Syndrome. This descriptive, observational, and cross-sectional study was conducted in four public teaching hospitals in Fortaleza, Ceará, Brazil. Sound pressure levels in the environment were measured, and questionnaires were administered to collect sociodemographic data and assess perceptions of the work environment and Burnout symptoms. Saliva samples were collected at the beginning and end of work shifts for cortisol quantification. The average sound pressure ranged from 59.9 to 66.4 dB(A), exceeding the recommended levels set by Brazilian and international legislation. Among the 256 participants, the average age was 39.4 years, with 95% being female. The majority (70.9%) were nurses, and 22.7% were physicians. There was no significant association found between noise and Burnout Syndrome, nor with changes in cortisol levels. However, a significant association was observed between the perception of excessive noise and the sensation of a stressful work shift (p = 0.012). All evaluated professionals displayed symptoms of Burnout. The high sound pressure levels indicated that the assessed environments did not meet the recommended standards for acoustic comfort, and this was associated with the participants’ perception of stressful work shifts. While Burnout symptoms were evident in our participants, it was not possible to confirm a correlation with high noise levels.