Laila Choonara

Dr. Laila Choonara

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2026 in SA Heart
Verified
Journal Article
Open access
PDF file
LCLaila Choonara
Laila Choonara
MVMuhammed Vally
Muhammed Vally
Background: For decades, chlorthalidone (CTD) was favoured over hydrochlorothiazide (HCTZ) based on its longer half-life and historical efficacy data. However, recent high-powered pragmatic trials and large-scale observational cohorts challenge this preference. We aimed to synthesise contemporary evidence comparing the cardiovascular efficacy and metabolic safety of these two thiazide-type diuretics in patients with hypertension. Methods: We conducted a systematic review and meta-analysis of contemporary evidence. A comprehensive literature search was performed across PubMed, Scopus, and the Cochrane Central Register of Controlled Trials (CENTRAL) from inception through March 2026, supplemented by manual reference mining. Data were pooled using a random effects model to account for heterogeneity. For the primary outcome of major adverse cardiovascular events (MACE), we synthesised data from a large, randomised controlled trial (RCT) and 2 international observational cohorts. Secondary safety and renal outcomes were pooled from 4 studies. Heterogeneity was assessed using the I² statistic. Results: Seven studies (> 700 000 patients) were included. There was no significant difference in MACE between CTD and HCTZ (risk ratio [RR] 1.01, 95% confidence interval [CI] 0.83 to 1.24, moderate certainty). Renal outcomes were also similar. However, CTD was associated with a higher risk of hypokalaemia (RR 1.55, 95% CI 0.90 to 2.66, low certainty). Conclusion: CTD does not provide superior cardiovascular or renal protection compared with HCTZ. Given the higher risk of hypokalaemia and monitoring burden, HCTZ remains a pragmatic first-line option in hypertension.

1 January 2026 in SA Heart
Verified
Journal Article
Open access
PDF file
LCLaila Choonara
Laila Choonara
MVM Vally
M Vally
SMSr Molla
Sr Molla
ZEZ Ellemdin
Z Ellemdin
AMA Mahomed
A Mahomed
ALAe Laher
Ae Laher
Background: For decades, chlorthalidone (CTD) was favoured over hydrochlorothiazide (HCTZ) based on its longer half-life and historical efficacy data. However, recent high-powered pragmatic trials and large-scale observational cohorts challenge this preference. We aimed to synthesise contemporary evidence comparing the cardiovascular efficacy and metabolic safety of these two thiazide-type diuretics in patients with hypertension. Methods: We conducted a systematic review and meta-analysis of contemporary evidence. A comprehensive literature search was performed across PubMed, Scopus, and the Cochrane Central Register of Controlled Trials (CENTRAL) from inception through March 2026, supplemented by manual reference mining. Data were pooled using a random effects model to account for heterogeneity. For the primary outcome of major adverse cardiovascular events (MACE), we synthesised data from a large, randomised controlled trial (RCT) and 2 international observational cohorts. Secondary safety and renal outcomes were pooled from 4 studies. Heterogeneity was assessed using the I² statistic. Results: Seven studies (> 700 000 patients) were included. There was no significant difference in MACE between CTD and HCTZ (risk ratio [RR] 1.01, 95% confidence interval [CI] 0.83 to 1.24, moderate certainty). Renal outcomes were also similar. However, CTD was associated with a higher risk of hypokalaemia (RR 1.55, 95% CI 0.90 to 2.66, low certainty). Conclusion: CTD does not provide superior cardiovascular or renal protection compared with HCTZ. Given the higher risk of hypokalaemia and monitoring burden, HCTZ remains a pragmatic first-line option in hypertension.

Verified
Journal Article
Open access
PDF file
LPLeora Porter
Leora Porter
LCLaila Choonara
Laila Choonara
SNSabrina Naude
Sabrina Naude
RRRaeesah Rajah
Raeesah Rajah
NKNameer Khan
Nameer Khan
ALAbdullah Laher
Abdullah Laher
Background: Sleep deprivation impairs executive function through the disruption of cerebral energy homeostasis. Creatine supplementation may mitigate these effects by enhancing phosphocreatine availability and supporting adenosine triphosphate regeneration during periods of sleep deprivation. Objective: We aimed to systematically review the evidence evaluating the effects of creatine supplementation on executive function during sleep deprivation. Methods: A systematic search of PubMed, Scopus, and Web of Science was conducted from database inception to June 2026. Randomized controlled trials evaluating creatine supplementation in sleep-deprived adults and reporting quantitative executive function metrics were eligible for inclusion. Data extraction and risk of bias assessment were performed independently by two reviewers. Results: Five eligible publications representing four independent randomized controlled trial cohorts (82 analysed participants) were included. Creatine supplementation was associated with improvements in selected executive-function measures, particularly logical reasoning, working memory and central executive tasks, although effects varied across cognitive domains. Neuroimaging findings from one cohort, reported in two publications, indicated alterations in cerebral high-energy phosphate metabolism and reduced hemispheric metabolic asymmetry following creatine administration. Conclusions: Creatine supplementation may attenuate selected executive-function impairments during acute sleep deprivation, although the evidence is limited by small samples, methodological heterogeneity and overlapping publications. Larger randomized trials using standardized sleep-deprivation protocols and cognitive outcome measures are required to confirm efficacy and determine optimal dosing strategies.

1 September 2026 in South African Journal of Surgery
Verified
Journal Article
Closed access
MVMuhammed Vally
Muhammed Vally
LCLaila Choonara
Laila Choonara
IBI Berkowitz
I Berkowitz
BJB Jacobson
B Jacobson
SLS Louw
S Louw

13 November 2026 in Canadian Journal of Emergency Medicine
Verified
Journal Article
Open access
PDF file
LCLaila Choonara
Laila Choonara
MVMuhammed Vally
Muhammed Vally
AMAdam Mahomed
Adam Mahomed
ALAbdullah E. Laher
Abdullah E. Laher
Objectives: Supplemental oxygen is a cornerstone of emergency care but has a narrow therapeutic window, with both hypoxemia and hyperoxia associated with adverse outcomes. Despite guideline-recommended oxygen saturation targets, manual oxygen titration in acute care settings is frequently inaccurate due to human, system, and workflow limitations. Automated closed-loop oxygen titration systems, which continuously adjust oxygen delivery to maintain predefined saturation targets, have emerged as a potential solution. This systematic review and meta-analysis evaluates the effectiveness of automated oxygen titration compared with standard manual titration in adult emergency care. Methods: The study protocol was registered with the international prospective register of systematic reviews (PROSPERO). A comprehensive literature search was conducted across PubMed, Scopus, Web of Science, the Cochrane Library, and Google Scholar. Eligible studies involving adult patients receiving emergency care were identified, with full-text review and data extraction performed in accordance with the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines. Results: Twenty-two records were identified; four met inclusion criteria, including three randomized controlled trials ( n = 286) and one prospective observational study. In the meta-analysis, automated titration significantly increased time within oxygen saturation target ranges compared to manual care (mean difference 22.9%; 95% CI 9.6–36.2). While initial heterogeneity was high ( I 2 = 85.7%), sensitivity analysis excluding one high-performing manual cohort eliminated variance ( I 2 = 0%) and confirmed a robust treatment effect (mean difference 29.6%; 95% CI 23.7–35.6). The available data are limited to these surrogate physiological endpoints; evidence demonstrating improvements in patient-centered clinical outcomes remains absent. Conclusion: Automated closed-loop titration demonstrates superior physiological precision in oxygen saturation target maintenance compared to manual care in emergency settings. While it effectively minimizes exposure to hypoxaemia and hyperoxia extremes, further large-scale trials are required to determine if these physiological improvements translate into definitive clinical benefits or improved patient-oriented outcomes.