The AC/DC hybrid microgrid has a large-scale and complex control process. It is of great significance and value to design a reasonable power coordination control strategy to maintain the power balance of the system. Based on hierarchical control, this paper designs a reasonable power coordination control strategy for AC/DC hybrid microgrid. For lower control, this paper designs a variety of control modes for each converter in different application scenarios. For the higher control, this paper analyzes the working mode of the system and designs the power coordination control strategy under the grid-connected and isolated island mode. In grid-connected operation, the DC bus voltage can be stabilized by adjusting the operation mode of the DC energy storage and the on-off of the secondary load. In isolated island operation, the DC sub-microgrid is the main microgrid, and the DC energy storage is the main power regulating equipment. This is based on the principle of “energy is in short supply in the system, DC energy storage finally discharge, energy supply exceeds demand in the system, DC energy storage gives priority to charging” of DC energy storage. By adjusting the control strategy of the micro-source, the reference power, and the on-off of the secondary load, the overall power balance is maintained. The Matlab/Simulink simulation software was used to build the AC/DC hybrid microgrid simulation model, which verified the effectiveness and stability of the proposed power coordination control strategy under various operating conditions.
In microgrids, paralleled converters can increase the system capacity and conversion efficiency but also generate zero-sequence circulating current, which will distort the AC-side current and increase power losses. Studies have shown that, for two paralleled three-phase voltage-source pulse width modulation (PWM) converters with common DC bus controlled by space vector PWM, the zero-sequence circulating current is mainly related to the difference of the zero-sequence duty ratio between the converters. Therefore, based on the traditional control ideal of zero-vector action time adjustment, this paper proposes a zero-sequence circulating current suppression strategy using proportional–integral quasi-resonant control and feedforward compensation control. Firstly, the dual-loop decoupled control was utilized in a single converter. Then, in order to reduce the amplitude and main harmonic components of the circulating current, a zero-vector duty ratio adjusting factor was initially generated by a proportional–integral quasi-resonant controller. Finally, to eliminate the difference of zero-sequence duty ratio between the converters, the adjusting factor was corrected by a feedforward compensation link. The simulation mode of Matlab/Simulink was constructed for the paralleled converters based on the proposed control strategy. The results verify that this strategy can effectively suppress the zero-sequence circulating current and improve power quality.
Period detection technology for weak characteristic signals is very important in the fields of speech signal processing, mechanical engineering, etc. Average magnitude difference function (AMDF) is a widely used method to extract the period of periodic signal for its low computational complexity and high accuracy. However, this method has low detection accuracy when the background noise is strong. In order to improve this method, this paper proposes a new method of period detection of the signal with single period based on the morphological self-complementary Top-Hat (STH) transform and AMDF. Firstly, the signal is de-noised by the morphological self-complementary Top-Hat transform. Secondly, the average magnitude difference function of the noise reduction sequence is calculated, and the falling trend is suppressed. Finally, a calculating adaptive threshold is used to extract the peaks at the position equal to the period of periodic signal. The experimental results show that the accuracy of periodic extraction of AMDF after Top-Hat filtering is better than that of AMDF directly. In summary, the proposed method is reliable and stable for detecting the periodic signal with weak characteristics.
At present, the remote meter reading problem for a large number of existing domestic diaphragm gas meters has not been reliably solved. The diaphragm gas meter uses a physical structure to measure gas consumption, so the main problem of remote meter reading is the digitization of gas consumption. Although it is possible to digitize the consumption data by modifying the internal structure of the gas meter or adding sensors, thereby realizing the function of remote meter reading, the modification process is complicated, the modification cost is high, and manual meter reading can only be used for the existing diaphragm gas meters. For this reason, this paper proposes an indirect measurement method of gas consumption based on gas pressure signal detection. The method can digitalize the metering results of the mechanical diaphragm gas meter and develop a state detection function by analyzing the pressure signal of the outlet of the meter without modifying the internal structure of a meter, thus addressing the key difficulties in the construction of a gas meter remote meter reading system. The experimental results show that this method has small calculation error and high reliability.