Shengjie Ma

Dr. Shengjie Ma

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2025 in Optics & Laser Technology
Verified
Journal Article
Closed access
SMShengjie Ma
Shengjie Ma
ZXZhengdong Xiong
Zhengdong Xiong
LWLi Wang
Li Wang
RDRenqin Dou
Renqin Dou
QZQingli Zhang
Qingli Zhang
HJHaihe Jiang
Haihe Jiang

9 March 2026 in Optics Express
Verified
Journal Article
Closed access
ZLZiran Liu
Ziran Liu
SMShengjie Ma
Shengjie Ma
XWXiangyizheng Wu
Xiangyizheng Wu
TCTingqing Cheng
Tingqing Cheng
LZLing Zhang
Ling Zhang
LWLi Wang
Li Wang
A Yb:YAG crystal with a gradient dopant of 0.11∼1.36 at.% Yb 3+ is designed, and its laser performance is demonstrated in a laser diode single-end pumped configuration. Compared with the homogeneous-doped crystal, the laser performance of the gradient-doped crystal is significantly improved due to the reduced thermal effects. The maximum output power of 60.2 W with the maximum optical-to-optical conversion efficiency of 53.2% is obtained in continuous-wave operation at 1030 nm, and the corresponding slope efficiency is 61.4%. The results show that the gradient-doped Yb:YAG crystal has advantages of mitigating thermal effects and excellent gain performance, and it is proven that the gradient-doped Yb:YAG crystal is effective for high-efficiency output at room temperature.

26 August 2025 in Optics Express
Verified
Journal Article
Closed access
RDRenqin Dou
Renqin Dou
LHLei Huang
Lei Huang
SMShengjie Ma
Shengjie Ma
JGJinyun Gao
Jinyun Gao
LWLi Wang
Li Wang
QZQingli Zhang
Qingli Zhang
High-symmetry gradient-doped laser crystals were specifically engineered for dual-end-pumped configurations to enhance laser performance. Two gradient-doped laser crystals were successfully fabricated, a 0.17-0.38-0.17 at% Nd:YAG rod and a 0.18-0.32-0.18 at% Nd:GdYAG rod. The output power, beam quality, and thermal characteristics were systematically compared with a conventional 0.6 at% uniformly doped Nd:YAG crystal. At 20 W pump power, the axial temperature differential in the gradient-doped crystal measured 37°C, representing a two-thirds reduction compared to the uniformly doped 0.6 at% Nd:YAG reference. The 0.17-0.38-0.17 at% Nd:YAG rod achieved a maximum output power of 14.47 W with 51.7% slope efficiency, representing 45.1% and 62.1% improvements respectively over uniformly doped 0.6 at% Nd:YAG. At 9 W output power, the beam quality factors were measured to be Mx2 = 2.347 and My2 = 2.217 for the 0.17-0.38-0.17 at% Nd:YAG crystal. This work establishes gradient doping as an effective strategy for simultaneous improvement of thermal management, power scaling, and beam quality in diode-pumped solid-state lasers.

5 June 2025 in Photobiomodulation, Photomedicine, and Laser Surgery
Verified
Journal Article
Closed access
ZXZhengdong Xiong
Zhengdong Xiong
HWHao Wu
Hao Wu
KLKe Li
Ke Li
ZLZiran Liu
Ziran Liu
JXJiliang Xu
Jiliang Xu
SMShengjie Ma
Shengjie Ma
Objectives: The aim of this study is to investigate the impact of water mist flow rate on the energy stability of Erbium - doped Yttrium Aluminum Garnet (Er:YAG) laser and ablation of bone. Materials and Methods: The pig tibiae surface was ablated with Er:YAG laser (100 mJ, 20 Hz, 100 μs) at the flow rate of water mist of 0, 3, 6, 9, 12 mL/min, respectively, for 1 min each. An energy meter was used to record the energy of each laser pulse under different water mist flow rates. A thermocouple was inserted into the bone marrow cavity to record the temperature changes. Infrared thermography, stereomicroscope, and electronic balance were employed to record the surface temperature, morphology, and mass changes, respectively. Results: As the water mist flow rate escalates, the laser energy experiences a notable attenuation of 27.4%, and the stability parameter Root Mean Square (RMS) escalates by a factor of 30. Despite the relatively minor temperature change within the bone marrow cavity, obviously different surface morphologies are evident. In cases where water mist is less than 3 mL/min, the surface temperature soars, resulting in carbonization. Conversely, when the water mist is greater than 9 mL/min, the ablating mass deteriorates significantly, to merely 25.2% of the value without water mist cooling. Conclusions: The water mist can affect the laser energy reaching the bone surface and its stability. When the water mist is insufficient, surface temperatures rise, causing carbonization. Conversely, it significantly reduces the ablating mass. Therefore, it is crucial to adjust the amount of water mist appropriately in erbium laser ablated bone. Given such large fluctuations in laser energy, the accuracy of erbium laser bone ablation is dramatically reduced, and the use of water mist cooling should be carefully considered.

29 October 2026 in Photonics
Verified
Journal Article
Open access
PDF file
SMShengjie Ma
Shengjie Ma
ZLZiran Liu
Ziran Liu
LWLi Wang
Li Wang
Renqin DouRenqin Dou
Renqin Dou
Qingli ZhangQingli Zhang
Qingli Zhang
HJHaihe Jiang
Haihe Jiang
A novel frequency-doubled laser using an end-pumped gradient-doped Nd:YAG crystal with continuously increasing dopant concentration to lower the thermal effect of the gain medium is proposed. By controlling the beam waist size of the fundamental wave and optimizing both the length and temperature of KTP crystals to enhance second-harmonic generation efficiency, the maximum output power with high beam quality is achieved at 532 nm. The second-harmonic generation efficiency reaches 59.8%, with a shortest pulse duration of 6.5 ns and a corresponding peak power of 469 kW. The beam qualities are Mx2=1.32 and My2=1.36, and the power instability is 0.24% (RMS). To the best of our knowledge, this is the first systematic SHG study of a continuously graded-doped Nd:YAG end-pumped laser, achieving higher-efficiency green laser output under near-diffraction-limited beam quality. This development holds significant importance for advancing the progress of high-performance frequency-doubled lasers.