Meng Wu

Dr. Meng Wu


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2023 in Frontiers in Oncology
Verified
Journal Article
Open access
YSYuan Song
Yuan Song
MWMeng Wu
Meng Wu
RZRuhai Zhou
Ruhai Zhou
PZPing Zhao
Ping Zhao
DMDan Mao
Dan Mao
Objective: To investigate the safety and mid-term outcomes of hydrodissection-assisted microwave ablation (MWA) of hepatocellular carcinoma (HCC) in various difficult locations.Methods: A total of 131 HCC patients who underwent ultrasound-guided MWA from March 2017 to March 2019 were included. Following ultrasound examination, patients with tumors at difficult locations were treated with hydrodissection-assisted MWA (hydrodissection group), while those with tumors at conventional locations received MWA (control group). Both groups were compared concerning baseline characteristics, ablation parameters, complete ablation rates, and complication rates. Kaplan-Meier curves analyzed local tumor progression and overall survival, with stratified analysis for different difficult locations (adjacent to gastrointestinal tract, diaphragm, and subcapsular tumors). Additionally, Cox regression analyses were conducted to assess the impact of different difficult locations on these outcomes.Results: Complete ablation rates were similar between the hydrodissection and control groups (91.4% vs. 95.2%, P>0.05). Postoperative complications occurred in three patients, including liver abscess and biliary injury. No significant differences in major or minor complication rates were found between the groups (P>0.05). Local tumor progression was detected in 11 patients (8.4%) at the end of the follow-up period. Neither cumulative local tumor progression rate (P=0.757) nor overall survival rate (P=0.468) differed significantly between the groups. Stratified analysis showed no effect of tumor location difficulty on cumulative local tumor progression or overall survival. Tumor number and size served as independent predictors for overall survival, while minimal ablation margin ≤ 5mm independently predicted local tumor progression. In contrast, the tumor location was not statistically significant. Sensitivity analyses corroborated the robustness of the models.Conclusion: Hydrodissection-assisted MWA for HCC in various difficult locations demonstrated safe and effective, with complete ablation and mid-term outcomes comparable to those for tumors in conventional locations.

14 May 2025 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
MWMinfang Wang
Minfang Wang
WCWanjun Chen
Wanjun Chen
RRRuiping Ren
Ruiping Ren
YLYuanwei Lin
Yuanwei Lin
JTJiawen Tang
Jiawen Tang
MWMeng Wu
Meng Wu
Background: Peritumoral characteristics demonstrate significant predictive value for neoadjuvant chemotherapy (NAC) response in breast cancer (BC) through tumor-stromal interactions. Radiomics analysis of peritumoral regions has shown robust capability in predicting treatment outcomes; however, the optimal peritumoral thickness for maximizing predictive accuracy remains undefined.Objective: To establish a clinically implementable framework for early identification of NAC non-responders through standardized prediction modeling. This study aims to determine the optimal peritumoral thickness for NAC response prediction by training and systematically comparing artificial intelligence (AI)-driven radiomics models across multiple peritumoral zones using Automated Breast Volume Scanning (ABVS).Methods: A total of 402 BC patients who received NAC were retrospectively analyzed. Pre-treatment ABVS images were processed to extract radiomic features from five regions of interest (ROIs): the intratumoral region (R0) and four consecutive peritumoral zones (R2-R8) extending outward at 2-mm intervals. The study cohort was divided into training and testing cohorts. ROI-specific TabNet models were developed using the training cohort data. Comparative analysis was performed in the testing cohort through comprehensive performance evaluation, including discrimination, calibration, clinical utility assessment, and classification metrics, to identify the optimal peritumoral zone. The radiomics features of the best-performing model were ranked by importance, with subsequent ablation studies validating the predictive contribution of high-ranking features.Results: Among the study population, 138 patients (34.3%) were classified as NAC non-responders. Model evaluation demonstrated progressively improved predictive performance from R0 to R6, with area under the ROC curves increasing from 0.681 to 0.845. The R6 model demonstrated optimal performance with accuracy of 0.810 and precision of 0.765. The combined model integrating R0 and R6 features enhanced predictive capability, achieving accuracy of 0.909, precision of 0.841, and recall of 0.902. Feature importance analysis identified textural heterogeneity and volumetric characteristics as the most influential variables, with the top features derived predominantly from the 6-mm peritumoral region.Conclusion: The 6-mm peritumoral zone demonstrated optimal predictive value for NAC response, with the AI-driven combined intratumoral-peritumoral model achieving superior performance. This standardized ABVS-based radiomics approach enables early identification of potential NAC non-responders, facilitating timely therapeutic modifications.

22 June 2022 in Future Oncology
Verified
Journal Article
Closed access
WZWeixia Zhou
Weixia Zhou
MWMeng Wu
Meng Wu
HLHongxia Lin
Hongxia Lin
WCWanjun Chen
Wanjun Chen
GLGuowen Lu
Guowen Lu
GCGun Chen
Gun Chen
Background: This prospective study compared the diagnostic value of tumor stiffness and serum soluble E-cadherin (sE-cadherin) expression for predicting response to neoadjuvant therapy in HER2-posi... Plain language summary HER2 positivity in breast cancer is associated with a poor prognosis and shortened overall survival. For patients with HER2-positive early breast cancer, the standard neoadju...

26 October 2021 in Evidence-Based Complementary and Alternative Medicine
Verified
Journal Article
Open access
PDF file
YLYupeng Lan
Yupeng Lan
TGTengfen Gong
Tengfen Gong
RZRuhai Zhou
Ruhai Zhou
MWMeng Wu
Meng Wu
ZLZhenzhen Liu
Zhenzhen Liu
Objective. To compare and analyze the diagnosis value of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) after treating advanced renal cancer patients with Yiqi Jiedu decoction. Methods. The case data of 60 patients diagnosed with advanced renal cancer from January 2013 to January 2021 at the Affiliated People’s Hospital of Ningbo University were retrospectively analyzed, 30 patients who accepted the conventional treatment were included in the control group, and the rest treated with Yiqi Jiedu decoction on the basis of conventional treatment were included in the study group. After treatment, patients in both groups received the CEUS and CECT examinations, the diagnosis efficacy of both examinations was evaluated with the ROC curve, and the overall survival (OS) of patients was analyzed. Results. No significant between-group differences in the general information were observed ( ); the clinical remission rate and disease control rate were not significantly different between the two groups ( ); the enhancement and attenuation, degree of enhancement, uniformity of enhancement, and pseudocapsule sign of the CEUS and CECT examinations were not remarkably different ( ); according to the results of CEUS and CECT examinations, the maximum diameters of tumor after treatment were smaller in the study group than in the control group, but with no significant between-group difference ( ); in addition, there were no obvious differences in determining the maximum diameter of tumor by CEUS and CECT ( ), and the results of the maximum diameter of tumor determined by CEUS, CECT, and pathological specimen were not statistically different ( ); as for the diagnosis efficacy, the result was CEUS + CECT > CEUS > CECT; and the OS of patients in the study group was longer than those in the control group. Conclusion. The patients treated with Yiqi Jiedu decoction obtain longer OS, and the application value of CEUS combined with CECT in the treatment effect and prognosis of patients with advanced renal cancer is higher.

10 March 2026 in Discover Oncology
Verified
Journal Article
Open access
PDF file
JLJienv Lou
Jienv Lou
JXJiahan Xu
Jiahan Xu
DMDan Mao
Dan Mao
YZYiting Zhao
Yiting Zhao
FYFanghe Ye
Fanghe Ye
MWMeng Wu
Meng Wu
Purpose Repeat prostate biopsy prediction remains limited by small patient cohorts that constrain artificial intelligence application despite theoretical advantages in capturing complex clinical patterns. This study develops and validates a meta-learning optimized TabNet framework using readily available clinical parameters to overcome sample size constraints and enhance repeat biopsy (RB) prediction accuracy through knowledge transfer from larger initial biopsy (IB) cohorts, with particular applicability to resource-limited settings where mpMRI remains unavailable. Meta-learning enables rapid model adaptation by leveraging knowledge from related tasks with minimal training examples. Methods This retrospective study analyzed 2,087 initial prostate biopsies and 139 subsequent RBs without mpMRI data. A two-stage training paradigm implemented Model-Agnostic Meta-Learning for pre-training on IB data, followed by fine-tuning on the RB cohort. Performance evaluation included discrimination analysis, calibration assessment, and decision curve analysis compared to original TabNet and conventional machine learning approaches, with classification performance benchmarked against established clinical risk calculators. Results Among 139 RB patients, cancer was detected in 40 cases (28.8%), including 31 clinically significant cancers (75.5%). On the independent testing set of 42 patients, meta-learning TabNet achieved superior discriminative performance (AUROC 0.872) compared to XGBoost (0.808), original TabNet (0.800), and conventional approaches. The model demonstrated optimal calibration (Brier score 0.068, ECE 0.100) and high specificity (90.0%) with only three false positives, substantially outperforming ERSPC and PCPT calculators. Conclusion Meta-learning optimization successfully addresses sample size limitations in repeat prostate biopsy prediction without requiring advanced imaging. This provides an evidence-based decision support tool enhancing diagnostic accuracy while minimizing unnecessary procedures.