The unprecedented growth in artificial intelligence (AI) workloads, recently dominated by large language models (LLMs) and vision-language models (VLMs), has intensified power and cooling demands in data centers. This study benchmarks LLMs and VLMs on two HGX nodes, each with 8x NVIDIA H100 graphics processing units (GPUs), using liquid and air cooling. Leveraging GPU Burn, Weights and Biases, and IPMItool, we collect detailed thermal, power, and computation data. Results show that the liquid-cooled systems maintain GPU temperatures between 41-50 degrees Celsius, while the air-cooled counterparts fluctuate between 54-72 degrees Celsius under load. This thermal stability of liquid-cooled systems yields 17 percent higher performance (54 TFLOPs per GPU vs. 46 TFLOPs per GPU), improved performance per watt, reduced energy overhead, and greater system efficiency than the air-cooled counterparts. These findings underscore the energy and sustainability benefits of liquid cooling, offering a compelling path forward for hyperscale data centers s

23 June 2026 in AI
Verified
Journal Article
Open access
PDF file
MSMuhammad Ali Shafique
Muhammad Ali Shafique
ILImran Latif
Imran Latif
HUHayat Ullah
Hayat Ullah
ANAlex C. Newkirk
Alex C. Newkirk
Arslan MunirArslan Munir
Arslan Munir
The rapid scaling of large language model (LLM) training has intensified demand for Graphics Processing Unit (GPU) clusters balancing throughput with energy efficiency. While NVIDIA’s H100 and B200 architectures are increasingly deployed in production datacenters, their comparative behavior under distributed training remains insufficiently characterized beyond vendor specifications, leaving datacenter operators without empirical guidance on metrics such as TFLOPs/kW and tokens-per-kilojoule. This work presents a system-level evaluation of single-node 8× H100 and 8× B200 configurations using Distributed Data Parallel (DDP) training across LLMs and vision–language models (VLMs) ranging from 7B to 32B parameters, spanning various real AI workload scenarios. We benchmark end-to-end throughput, utilization, power, energy, TFLOPs/kW, and tokens-per-kilojoule, complemented by architectural analysis explaining observed behavioral differences. Across LLM workloads, B200 achieves higher utilization (1–6%), faster training (up to 15%), and greater compute efficiency (up to 32% higher TFLOPs/GPU), attributable to higher memory bandwidth and large streaming multiprocessor (SM) count. However, B200 exhibits lower TFLOPs/kW and tokens-per-kilojoule, revealing a fundamental trade-off: throughput gains come at a measurable energy cost per useful token. VLM results further expose model-dependent asymmetries, with B200 consuming disproportionately more energy for lighter compute kernels due to elevated baseline power draw. These findings provide an empirical framework distinguishing compute efficiency from energy efficiency across next-generation GPU nodes, offering practical guidance for energy-aware AI datacenter design.