Mikhael F El-Chami

Dr. Mikhael F El-Chami


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
TNTamim M. Nazif
Tamim M. Nazif
JDJosé M. Dizon
José M. Dizon
RHRebecca T Hahn
Rebecca T Hahn
KXKe Xu
Ke Xu
VBVasilis Babaliaros
Vasilis Babaliaros
SKSusheel K. Kodali
Susheel K. Kodali

1 December 2018 in Heart Rhythm
Verified
Journal Article
Open access
MEMikhael F El-Chami
Mikhael F El-Chami
FAFaisal Al-Samadi
Faisal Al-Samadi
NCNicolas Clementy
Nicolas Clementy
CGChristophe Garweg
Christophe Garweg
JMJose Luis Martinez-Sande
Jose Luis Martinez-Sande
PRPaul R. Roberts
Paul R. Roberts
Early results of the Micra Investigational Device Exemption (IDE) study and Micra Post-Approval Registry (PAR) demonstrated excellent safety and efficacy performance; however, intermediate-term results across a large patient population in the real-world setting have not been evaluated. We report updated performance of the Micra transcatheter pacemaker from a worldwide PAR and compare it with the IDE study as well as a transvenous historical control. The safety objective of the analysis was system- or procedure-related major complications through 12 months postimplantation. We compared the major complication rate with that of the 726 patients from the IDE and with a reference data set of 2667 patients with transvenous pacemakers by using a Fine-Gray competing risk model. The Micra device was successfully implanted in 1801 of 1817 patients (99.1%). The mean follow-up period was 6.8 ± 6.9 months. Through 12 months, the major complication rate was 2.7% (95% confidence interval [CI] 2.0%-3.7%). The risk of major complications for Micra PAR patients was 63% lower than that for patients with transvenous pacemakers through 12 months postimplantation (hazard ratio 0.37; 95% CI 0.27-0.52; P < .001). The major complication rate trended lower in the PAR than in the IDE study (hazard ratio 0.71; 95% CI 0.44-1.1; P = .160), driven by the lower pericardial effusion rate in the PAR. There were 3 cases of infection associated with the procedure, but none required device removal and there were no battery or telemetry issues. Pacing thresholds were low and stable through 12 months postimplantation. Performance of the Micra transcatheter pacemaker in international clinical practice remains consistent with previously reported data. Major complications were infrequent and occurred 63% less often compared to transvenous systems. Micra Transcatheter Pacing System Post-Approval Registry ClinicalTrials.gov identifier: NCT02536118; Micra Transcatheter Pacing Study ClinicalTrials.gov identifier: NCT02004873.

1 March 2010 in JACC
Verified
Journal Article
Closed access
MEMikhael F El-Chami
Mikhael F El-Chami
PKPatrick Kilgo
Patrick Kilgo
VTVinod Thourani
Vinod Thourani
OLOmar M. Lattouf
Omar M. Lattouf
DDDavid B. Delurgio
David B. Delurgio
JPJohn D. Puskas
John D. Puskas

1 September 2017 in Heart Rhythm
Verified
Journal Article
Open access
PRPaul R. Roberts
Paul R. Roberts
NCNicolas Clementy
Nicolas Clementy
FSFaisal Al Samadi
Faisal Al Samadi
CGChristophe Garweg
Christophe Garweg
JMJose Luis Martinez-Sande
Jose Luis Martinez-Sande
MEMikhael F El-Chami
Mikhael F El-Chami
First-in-man studies of leadless pacemakers have demonstrated high rates of implant success, and safety and efficacy objectives were achieved. Outside of the investigational setting, there are concerns, particularly over cardiac effusion and perforation, device dislodgement, infection, telemetry, and battery issues. The acute performance of the Micra transcatheter pacemaker from a worldwide Post-Approval Registry is reported. The registry is an ongoing prospective single-arm observational study designed to assess the safety and effectiveness of Micra in the post-approval setting. The safety end point was system- or procedure-related major complications at 30 days post implant. We compared the major complication rate with that of the 726 patients from the investigational study. Electrical performance was also characterized. The device was successfully implanted in 792 of 795 registry patients (99.6%) by 149 implanters at 96 centers in 20 countries. Through 30 days post implant, a total of 13 major complications occurred in 12 patients, for a major complication rate of 1.51% (95% confidence interval, 0.78%-2.62%). Major complications included cardiac effusion/perforation (1, 0.13%), device dislodgement (1, 0.13%), and sepsis (1, 0.13%). After adjusting for baseline differences, the rate of major complications in the registry trended lower than the investigational trial (odds ratio, 0.58, 95% confidence interval, 0.27-1.25; P = .16). Early pacing capture thresholds were low and stable. Performance of the Micra transcatheter pacemaker in a real-world setting demonstrates a high rate (99.6%) of implant success and low rate (1.51%) of major complications through 30 days post implant. In particular, the rates of pericardial effusion, device dislodgement, and infection were low, reinforcing the positive results seen in the investigational study.

1 May 2017 in Heart Rhythm
Verified
Journal Article
Open access
GDGabor Z. Duray
Gabor Z. Duray
PRPhilippe Ritter
Philippe Ritter
MEMikhael F El-Chami
Mikhael F El-Chami
CNCalambur Narasimhan
Calambur Narasimhan
RORazali Omar
Razali Omar
DRDwight Reynolds
Dwight Reynolds
Early performance of the Micra transcatheter pacemaker from the global clinical trial reported a 99.2% implant success rate, low and stable pacing capture thresholds, and a low (4.0%) rate of major complications up to 6 months. The purpose of this report was to describe the prespecified long-term safety objective of Micra at 12 months and electrical performance through 24 months. The Micra Transcatheter Pacing Study was a prospective single-arm study designed to assess the safety and efficacy of the Micra VVIR leadless/intracardiac pacemaker. Enrolled patients met class I or II guideline recommendations for de novo ventricular pacing. The long-term safety objective was freedom from a system- or procedure-related major complication at 12 months. A predefined historical control group of 2667 patients with transvenous pacemakers was used to compare major complication rates. The long-term safety objective was achieved with a freedom from major complication rate of 96.0% at 12 months (95% confidence interval 94.2%-97.2%; P < .0001 vs performance goal). The risk of major complications for patients with Micra (N = 726) was 48% lower than that for patients with transvenous systems through 12 months postimplant (hazard ratio 0.52; 95% confidence interval 0.35-0.77; P = .001). Across subgroups of age, sex, and comorbidities, Micra reduced the risk of major complications compared to transvenous systems. Electrical performance was excellent through 24 months, with a projected battery longevity of 12.1 years. Long-term performance of the Micra transcatheter pacemaker remains consistent with previously reported data. Few patients experienced major complications through 12 months of follow-up, and all patient subgroups benefited as compared to transvenous pacemaker historical control group.

1 September 2015 in JACC
Verified
Journal Article
Closed access
PMPamela B. Morris
Pamela B. Morris
BFBrian A. Ference
Brian A. Ference
EJEiman Jahangir
Eiman Jahangir
DFDmitriy N. Feldman
Dmitriy N. Feldman
JRJohn J. Ryan
John J. Ryan
NBNeal L. Benowitz
Neal L. Benowitz