Ernesto Bruschi

Dr. Ernesto Bruschi


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2011 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
GBGiovanni B. Bruschi
Giovanni B. Bruschi
RCRoberto Crespi
Roberto Crespi
Paolo CapparèPaolo Capparè
Paolo Capparè
FBFabrizio Bravi
Fabrizio Bravi
EBErnesto Bruschi
Ernesto Bruschi
GEGherlone Felice Enrico
Gherlone Felice Enrico

1 January 2014 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
GBGiovanni B. Bruschi
Giovanni B. Bruschi
RCRoberto Crespi
Roberto Crespi
Paolo CapparèPaolo Capparè
Paolo Capparè
NGNicola Maria Grande
Nicola Maria Grande
EBErnesto Bruschi
Ernesto Bruschi
GEGherlone Felice Enrico
Gherlone Felice Enrico
Giovanni B. Bruschi, MD, DDS/Roberto Crespi, MD, MS/Paolo Cappar?, MD/Nicola Grande, DDS/Ernesto Bruschi, DDS/Enrico Gherlone, MD, DMD, PhD: Purpose: The aim of this study was to evaluate the radiographic bone level changes after delayed implant placement at medium-term follow-up, with three elements kept constant: keratinized gingiva thickness, implant axes perpendicular to the opposing occlusal surface, and implants with a collar of 2 mm. Materials and Methods: Patients treated in a private practice setting were retrospectively enrolled in the study. They underwent delayed placement (4 to 8 weeks after extraction) of dental implants in edentulous premolar or molar regions. Implants followed a delayed loading protocol. Crestal bone levels were measured at baseline; at provisional prosthesis placement; at 1, 3, and 5 years; and at medium-term follow-up of healing from implant placement. Results: One hundred twenty patients received 135 implants (one or two implants per patient); 3 implants were lost. After a mean follow-up period of 9.71 ? 4.88 years, a survival rate of 97.76% was reported. At 1 year after implant placement, mean bone loss of ?1.5 ? 0.62 mm was found. At almost 3 years post?implant placement, a mean bone gain of +1.20 ? 0.49 mm was seen, which was statistically significantly different compared with 1 year. After this point, the bone levels remained stable; similar values were reported over time, with no significant differences. Conclusions: The mean vertical bone gain of +1.20 ? 0.49 mm seen at almost 3 years after implant placement in this study may be supported by both clinical parameters as presence of sufficiently thick keratinized gingiva (3 mm), implants with a 2-mm collar, and the axis of implant insertion perpendicular to the opposing occlusal surface.

1 June 1999
Verified
Journal Article
Closed access
ASA Scipioni
A Scipioni
GBG B Bruschi
G B Bruschi
GCG Calesini
G Calesini
EBErnesto Bruschi
Ernesto Bruschi
CMC De Martino
C De Martino

1 October 2019 in International Journal of Periodontics & Restorative Dentistry
Verified
Journal Article
Closed access
EBErnesto Bruschi
Ernesto Bruschi
PMPaolo Manicone
Paolo Manicone
PAPaolo De Angelis
Paolo De Angelis
LPLaura Papetti
Laura Papetti
RPRoberta Pastorino
Roberta Pastorino
ADAntonio D’ADdona
Antonio D’ADdona
Ernesto Bruschi, DDS/Paolo Francesco Manicone, DDS/Paolo De Angelis, DDS/Laura Papetti, DDS/Roberta Pastorino, PhD/Antonio D?Addona, DDS: This clinical study retrospectively analyzed cone beam computed tomography (CBCT) images to determine the potential influence of implant inclination on peri-implant marginal bone loss after 18 to 24 months of functional loading. Twenty-five consecutive patients presenting with an edentulous or partially edentulous maxilla or mandible and an adequate bone volume for receiving oral implants were selected for analysis of the marginal bone loss around tilted and/or axial implants. The study population included patients rehabilitated with Toronto bridges (TBs), fixed partial dentures (FPDs), or single crowns (SCs) on axial and/or tilted implants. The primary outcome was the CBCT analysis of peri-implant marginal bone level change, depending on inclination of implants and type of prostheses. The secondary outcome was analysis of survival and success rates of tilted and axial implants. A significant difference was observed for peri-implant buccal bone loss (mean of axials 0.42 ? 0.06; mean of tilted 0.70 ? 0.09) (P = .009). The difference in peri-implant lingual/palatal/mesial/distal bone loss was not significant between axial and tilted implants (P > .05). No significant difference was observed between the marginal bone level and the type of prostheses for both tilted and axial implants in all the assessed sites (P > .05). The success rate for both tilted and axial implants was 100%, and no complications were observed for all the prosthetic rehabilitations, with a 100% survival rate. Compared to axial implants, tilted implants showed a significant statistical difference for peri-implant buccal bone loss, but no other differences were observed for peri-implant bone loss or for implant survival and success rate. Fixed partial or total rehabilitation using tilted or axial implants, or with tilted and axial implants, could be a reliable technique with advantages to patients and operators.

15 May 1998
Verified
Journal Article
Closed access
GBG B Bruschi
G B Bruschi
ASA Scipioni
A Scipioni
GCG Calesini
G Calesini
EBErnesto Bruschi
Ernesto Bruschi

4 September 2021 in Heliyon
Verified
Journal Article
Open access
GBGiovanni Battista Bruschi
Giovanni Battista Bruschi
EBErnesto Bruschi
Ernesto Bruschi
LPLaura Papetti
Laura Papetti
Trans-crestal sinus lift procedures are well established. to retrospectively analyse the efficacy of a flapless trans-crestal maxillary sinus floor elevation and simultaneous dental implant placement based on the Localised Management of Sinus Floor (LMSF) technique suitable for cases with sufficient width of keratinized tissue and of crestal bone but insufficient vertical dimensions of the bone below the sinus. 71 sinus elevations with simultaneous implant placement were performed on 52 consecutive patients. Following an initial pilot bur transmucosal perforation, the Magnetic Mallet was used with progressively larger osteotomes. The mallet osteotomes are initially directed palatally, towards the cortex of the medial wall of the sinus, below the palato-nasal recess (PNR) and then redirected in a more vertical direction to create the final osteotomy for implant placement. No significant complications were reported in the post-operative phase. The cumulative success rate during the observation period was 95%. All successful implants were successfully loaded with metal-ceramic or monolithic zirconia crowns and bridges and remained in function during the observation period. Flapless Localised Management of Sinus Floor (LMSF) is a safe and effective surgical technique with minimal risks and with the advantage of low morbidity. Also, only native bone is used for augmentation and there is no need for additional grafting.