Fabrizio Giorgis

Prof. Fabrizio Giorgis

Department of Applied Science and Technology, Politecnico of Torino, C.so Duca degli Abruzzi 24, 10129 Torino, Italy

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2010 in Optics Express
Verified
Journal Article
Closed access
PDF file
FGFabrizio Giorgis
Fabrizio Giorgis
Emiliano DescroviEmiliano Descrovi
Emiliano Descrovi
CSCaterina Summonte
Caterina Summonte
LDLorenzo Dominici
Lorenzo Dominici
FMFrancesco Michelotti
Francesco Michelotti
Detection of glucose in water solution for several different concentrations has been performed with the purpose to determine the sensitivity of Near Infrared Bloch Surface Waves (λ = 1.55μm) upon refractive index variations of the outer medium. TE-polarized electromagnetic surface waves are excited by a prism on a silicon nitride multilayer, according to the Kretschmann configuration. The real-time reflectance changes induced by discrete variations in glucose concentration has been revealed and analyzed. Without using any particular averaging strategy during the measurements, we pushed the device detection limit down to a glucose concentration of 2.5mg/dL, corresponding to a minimum detectable refractive index variation of the water solution as low as 3.8·10−6.

23 September 2013 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
AVAlessandro Virga
Alessandro Virga
Paola RivoloPaola Rivolo
Paola Rivolo
Francesca FrascellaFrancesca Frascella
Francesca Frascella
AAAngelo Angelini
Angelo Angelini
Emiliano DescroviEmiliano Descrovi
Emiliano Descrovi
FGFabrizio Giorgis
Fabrizio Giorgis

24 November 2011 in Journal of Raman Spectroscopy
Verified
Journal Article
Closed access
PDF file
AVAlessandro Virga
Alessandro Virga
Paola RivoloPaola Rivolo
Paola Rivolo
Emiliano DescroviEmiliano Descrovi
Emiliano Descrovi
Alessandro ChiolerioAlessandro Chiolerio
Alessandro Chiolerio
GDGabriella Digregorio
Gabriella Digregorio
FGFabrizio Giorgis
Fabrizio Giorgis

1 April 1998 in Philosophical Magazine Part B
Verified
Journal Article
Closed access
FGFabrizio Giorgis
Fabrizio Giorgis
FGF. Giuliani
F. Giuliani
CPC. F. Pirri
C. F. Pirri
ETE. Tresso
E. Tresso
CSCaterina Summonte
Caterina Summonte
PRP. Rava
P. Rava
High-electronic quality hydrogenated amorphous silicon-nitrogen (a-Si1-xNx: H) films with an energy gap in the range 1.9-2.7eV have been deposited by plasma-enhanced chemical vapour deposition in silane-ammonia gas mixtures at two different gas residence times and in hydrogen-diluted silane-ammonia gas mixtures. Compositional, structural, electrical and optical properties have been investigated. For the first time the effects of hydrogen dilution of SiH4 + NH3 gas mixtures on the a-Si1-xNx: H network is reported. We have observed that hydrogen dilution decreases hydrogen incorporation and increases nitrogen incorporation, promoting a higher connectivity of the a-Si1-xNx :H network. All films show good electronic properties, comparable with or superior to those of amorphous silicon-carbon films, which are improved in films deposited from hydrogen-diluted gas mixtures

5 February 2013 in Sensors
Verified
Journal Article
Open access
PDF file
Francesca FrascellaFrancesca Frascella
Francesca Frascella
SRSerena Ricciardi
Serena Ricciardi
Paola RivoloPaola Rivolo
Paola Rivolo
VMValeria Moi
Valeria Moi
FGFabrizio Giorgis
Fabrizio Giorgis
FBFederico Bussolino
Federico Bussolino
A one-dimensional photonic crystal (1DPC) based on a planar stack of dielectric layers is used as an optical transducer for biosensing, upon the coupling of TE-polarized Bloch Surface Waves (BSW). The structure is tailored with a polymeric layer providing a chemical functionality facilitating the covalent binding of orienting proteins needed for a subsequent grafting of antibodies in an immunoassay detection scheme. The polymeric layer is impregnated with Cy3 dye, in such a way that the photonic structure can exhibit an emissive behavior. The BSW-coupled fluorescence shift is used as a means for detecting refractive index variations occurring at the 1DPC surface, according to a label-free concept. The proposed working principle is successfully demonstrated in real-time tracking of protein G covalent binding on the 1DPC surface within a fluidic cell.

21 May 2015 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
Andrea LambertiAndrea Lamberti
Andrea Lamberti
AVAlessandro Virga
Alessandro Virga
Alessandro Chiado'Alessandro Chiado'
Alessandro Chiado'
Angelica ChiodoniAngelica Chiodoni
Angelica Chiodoni
Katarzyna BejtkaKatarzyna Bejtka
Katarzyna Bejtka
FGFabrizio Giorgis
Fabrizio Giorgis
A novel SERS optofluidic sensor based on Ag-decorated TiO 2 nanotubes has been developed for repeatable detection of organic molecules and biological assays.