Detection of glucose in water solution for several different concentrations has been performed with the purpose to determine the sensitivity of Near Infrared Bloch Surface Waves (λ = 1.55μm) upon refractive index variations of the outer medium. TE-polarized electromagnetic surface waves are excited by a prism on a silicon nitride multilayer, according to the Kretschmann configuration. The real-time reflectance changes induced by discrete variations in glucose concentration has been revealed and analyzed. Without using any particular averaging strategy during the measurements, we pushed the device detection limit down to a glucose concentration of 2.5mg/dL, corresponding to a minimum detectable refractive index variation of the water solution as low as 3.8·10−6.
23 September 2013 in The Journal of Physical Chemistry C
High-electronic quality hydrogenated amorphous silicon-nitrogen (a-Si1-xNx: H) films with an energy gap in the range 1.9-2.7eV have been deposited by plasma-enhanced chemical vapour deposition in silane-ammonia gas mixtures at two different gas residence times and in hydrogen-diluted silane-ammonia gas mixtures. Compositional, structural, electrical and optical properties have been investigated. For the first time the effects of hydrogen dilution of SiH4 + NH3 gas mixtures on the a-Si1-xNx: H network is reported. We have observed that hydrogen dilution decreases hydrogen incorporation and increases nitrogen incorporation, promoting a higher connectivity of the a-Si1-xNx :H network. All films show good electronic properties, comparable with or superior to those of amorphous silicon-carbon films, which are improved in films deposited from hydrogen-diluted gas mixtures
A one-dimensional photonic crystal (1DPC) based on a planar stack of dielectric layers is used as an optical transducer for biosensing, upon the coupling of TE-polarized Bloch Surface Waves (BSW). The structure is tailored with a polymeric layer providing a chemical functionality facilitating the covalent binding of orienting proteins needed for a subsequent grafting of antibodies in an immunoassay detection scheme. The polymeric layer is impregnated with Cy3 dye, in such a way that the photonic structure can exhibit an emissive behavior. The BSW-coupled fluorescence shift is used as a means for detecting refractive index variations occurring at the 1DPC surface, according to a label-free concept. The proposed working principle is successfully demonstrated in real-time tracking of protein G covalent binding on the 1DPC surface within a fluidic cell.
A novel SERS optofluidic sensor based on Ag-decorated TiO 2 nanotubes has been developed for repeatable detection of organic molecules and biological assays.