Tzong-Jih Cheng

Tzong-Jih Cheng

Biomechatronics Engineering, National Taiwan University, Taipei, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
HCHsin-Ju Chen
Hsin-Ju Chen
RCRichie L.C. Chen
Richie L.C. Chen
BHBo-Chuan Hsieh
Bo-Chuan Hsieh
HHHsien-Yi Hsiao
Hsien-Yi Hsiao
YKYi Kung
Yi Kung
TCTzong-Jih Cheng
Tzong-Jih Cheng

1 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
HHHsien-Yi Hsiao
Hsien-Yi Hsiao
RCRichie L. C. Chen
Richie L. C. Chen
CCChih-Chi Chou
Chih-Chi Chou
TCTzong-Jih Cheng
Tzong-Jih Cheng
This study develops a hand-held stress assessment meter with a chemically colorimetric strip for determining salivary α-amylase activity, using a 3,5 dinitrosalicylic acid (DNS) assay to quantify the reducing sugar released from soluble starch via α-amylase hydrolysis. The colorimetric reaction is produced by heating the strip with a mini polyester heater plate at boiling temperature to form a brick red colored product, which measured at 525 nm wavelength. This investigation describes in detail the design, construction, and performance evaluation of a hand-held α-amylase activity colorimeter with a light emitted diode (LED) and photo-detector with built-in filters. The dimensions and mass of the proposed prototype are only 120 × 60 × 60 mm3 and 200 g, respectively. This prototype has an excellent correlation coefficient (>0.995), comparable with a commercial ultraviolet–visible spectroscope, and has a measurable α-amylase activity range of 0.1–1.0 U mL−1. The hand-held device can measure the salivary α-amylase activity with only 5 μL of saliva within 12 min of testing. This sensor platform effectively demonstrates that the level of salivary α-amylase activity increases more significantly than serum cortisol, the other physiological stressor biomarker, under physiologically stressful exercise conditions. Thus, this work demonstrates that the hand-held α-amylase activity meter is an easy to use and cost-effective stress assessment tool for psychoneuroendocrinology research.

9 June 2005 in Bioelectrochemistry
Verified
Journal Article
Closed access
PCPo-Chung Chen
Po-Chung Chen
PHPo-Chuan Hsieh
Po-Chuan Hsieh
RCRichie L.C. Chen
Richie L.C. Chen
TWTzu-Yu Wang
Tzu-Yu Wang
HHHsien-Yi Hsiao
Hsien-Yi Hsiao
TCTzong-Jih Cheng
Tzong-Jih Cheng

30 September 2006 in Bioelectrochemistry
Verified
Journal Article
Closed access
FCFu-Shiang Chang
Fu-Shiang Chang
PCPo-Chung Chen
Po-Chung Chen
RCRichie L.C. Chen
Richie L.C. Chen
FLFu-Ming Lu
Fu-Ming Lu
TCTzong-Jih Cheng
Tzong-Jih Cheng

2 March 2009 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
CNChi-Hua Nieh
Chi-Hua Nieh
PHPo-Chuan Hsieh
Po-Chuan Hsieh
PCPo-Chung Chen
Po-Chung Chen
HHHsien-Yi Hsiao
Hsien-Yi Hsiao
TCTzong-Jih Cheng
Tzong-Jih Cheng
RCRichie L.C. Chen
Richie L.C. Chen

9 May 2024 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
PTPei-Chia Tsai
Pei-Chia Tsai
RCRichie L.C. Chen
Richie L.C. Chen
PHPo-Chuan Hsieh
Po-Chuan Hsieh
TCTzong-Jih Cheng
Tzong-Jih Cheng