Boshi Liu

Dr. Boshi Liu

College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China
+1

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Talanta
Verified
Journal Article
Closed access
NZNan Zhang
Nan Zhang
BLBoshi Liu
Boshi Liu
XCXialian Cui
Xialian Cui
YLYutong Li
Yutong Li
JTJing Tang
Jing Tang
ZLZheng Li
Zheng Li

1 January 2022 in Talanta
Verified
Journal Article
Closed access
NZNan Zhang
Nan Zhang
JLJingrong Li
Jingrong Li
BLBoshi Liu
Boshi Liu
DZDi Zhang
Di Zhang
CZChengyu Zhang
Chengyu Zhang
ZLZheng Li
Zheng Li

3 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
HWHai-Xia Wang
Hai-Xia Wang
YZYu-Wen Zhao
Yu-Wen Zhao
ZLZheng Li
Zheng Li
BLBoshi Liu
Boshi Liu
DZDi Zhang
Di Zhang
Surface-enhanced Raman scattering (SERS) is one of the most special and important Raman techniques. An apparent Raman signal can be observed when the target molecules are absorbed onto the surface of the SERS substrates, especially on the “hot spots” of the substrates. Early research focused on exploring the highly active SERS substrates and their detection applications in label-free SERS technology. However, it is a great challenge to use these label-free SERS sensors for detecting hydrophobic or non-polar molecules, especially in complex systems or at low concentrations. Therefore, antibodies, aptamers, and antimicrobial peptides have been used to effectively improve the target selectivity and meet the analysis requirements. Among these selective elements, aptamers are easy to use for synthesis and modifications, and their stability, affinity and specificity are extremely good; they have been successfully used in a variety of testing areas. The combination of SERS detection technology and aptamer recognition ability not only improved the selection accuracy of target molecules, but also improved the sensitivity of the analysis. Variations of aptamer-based SERS sensors have been developed and have achieved satisfactory results in the analysis of small molecules, pathogenic microorganism, mycotoxins, tumor marker and other functional molecules, as well as in successful photothermal therapy of tumors. Herein, we present the latest advances of the aptamer-based SERS sensors, as well as the assembling sensing platforms and the strategies for signal amplification. Furthermore, the existing problems and potential trends of the aptamer-based SERS sensors are discussed.

15 January 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HWHaixia Wang
Haixia Wang
YZYuwen Zhao
Yuwen Zhao
SBSongtao Bie
Songtao Bie
TSTongchuan Suo
Tongchuan Suo
GJGuangcheng Jia
Guangcheng Jia
ZLZheng Li
Zheng Li
An aptamer-based electrochemical biosensor was successfully developed and applied in the rapid detection of pathogenic Escherichia coli (E. coli) in licorice extract. The thiolated capture probes were firstly immobilized on a gold electrode, and then the biotinylated aptamer probes for E. coli were introduced by hybridization with the capture probes. Due to the stronger interaction between the aptamer and the E. coli, a part of the biotinylated aptamers will dissociate from the capture probes in the presence of E. coli. The residual biotinylated aptamer probes can quantitatively bind with streptavidin-alkaline phosphatase. Subsequently, α-naphthyl phosphate substrate was catalytically hydrolyzed to generate electrochemical response, which could be recorded by a differential pulse voltammetry. The dependence of the peak current on the logarithm of E. coli concentration in the range from 5.0 × 102 colony forming units (CFU)/mL to 5.0 × 107 CFU/mL exhibited a linear trend with a detection limit of 80 CFU/mL. The relative standard deviation of 5 successive scans was 5.3%, 4.5% and 1.1% for 5.0 × 102, 5.0 × 105 and 5.0 × 107 CFU/mL E. coli, respectively. In the detection of the licorice extract samples, the results obtained from the proposed strategy and traditional culture counting method were close to each other, but the time consumption was only ~1/30 compared with the traditional method. These results demonstrate that the designed biosensor can be potentially utilized for rapid microbial examination in traditional Chinese medicine and relevant fields.

1 January 2022 in Toxicon
Verified
Journal Article
Closed access
NZNan Zhang
Nan Zhang
JLJingrong Li
Jingrong Li
BLBoshi Liu
Boshi Liu
HWHaixia Wang
Haixia Wang
DZDi Zhang
Di Zhang
ZLZheng Li
Zheng Li

9 August 2024 in International Communications in Heat and Mass Transfer
Verified
Journal Article
Closed access
JLJianguo Lu
Jianguo Lu
FDFei Deng
Fei Deng
WLWeibo Liu
Weibo Liu
JGJiajia Gao
Jiajia Gao
BLBoshi Liu
Boshi Liu
ZZZhexi Zhang
Zhexi Zhang