To describe and evaluate outcomes of Gamma Knife radiosurgery (GK) for the treatment of pituitary tumors over the past twenty years, a systematic review and meta-analysis according to PRISMA statement was performed. Articles counting more than 30 patients were included. A weighted random effects models was used to calculate pooled outcome estimates. From 459 abstract reviews, 52 retrospective studies were included. Among them, 18 reported on non-functioning pituitary adenomas (NFPA), 13 on growth hormone (GH)-secreting adenomas, six on adrenocorticotropic hormone (ACTH)-secreting adenomas, four on prolactin hormone (PRL)-secreting adenomas, and 11 on craniopharyngiomas. Overall tumor control and five-year progression free survival (PFS) estimate after one GK procedure for NFPA was 93% (95% CI 89–97%) and 95% (95% CI 91–99%), respectively. In case of secreting pituitary adenomas, overall remission (cure without need for medication) estimates were 45% (95% CI 35–54%) for GH-secreting adenomas, 64% (95% CI 0.52–0.75%) for ACTH-secreting adenomas and 34% (95% CI: 19–48%) for PRL-secreting adenomas. The pooled analysis for overall tumor control and five-year PFS estimate after GK for craniopharyngioma was 74% (95% CI 67–81%) and 70% (95% CI: 64–76%), respectively. This meta-analysis confirms and quantifies safety and effectiveness of GK for pituitary tumors.
Spinal cord injury (SCI) causes severe motor and sensory deficits, and there are currently no approved treatments for recovery. Nearly 70% of patients with SCI experience pathological muscle cocontraction and spasticity, accompanied by clinical signs such as patellar hyperreflexia and ankle clonus. The integration of epidural electrical stimulation (EES) of the spinal cord with rehabilitation has substantial potential to improve recovery of motor functions; however, abnormal muscle cocontraction and spasticity may limit the benefit of these interventions and hinder the effectiveness of EES in promoting functional movements. High-frequency excitation block introduced in peripheral nerve stimulation could reduce abnormal activity and lead to more physiological activation patterns. Here, we evaluated the application of high-frequency EES (HF-EES) in alleviating undesired muscular cocontraction and spasticity in two patients with motor incomplete SCI implanted with a commercial 32-channel EES paddle commonly used for pain therapy. To design custom HF-EES protocols, we first mapped the muscles targeted by different EES configurations. Our results showed that HF-EES substantially reduced patellar reflex in one participant and eliminated both patellar reflex and ankle clonus in the other participant. By combining HF-EES and low-frequency EES (LF-EES) to enhance functional movements with intensive rehabilitation, we observed notable improvements in lower limb kinematics, muscle strength, and clinical lower limb motor assessments over the trial period. This study suggests that HF-EES could be an important supplementary tool in SCI treatment, emphasizing the importance of personalized rehabilitation approaches and advanced tools to optimize EES treatments and offering hope for individuals with SCI-related motor deficits.