Theodora Slini

Dr. Theodora Slini

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2026 in Photobiomodulation, Photomedicine, and Laser Surgery
Verified
Journal Article
Closed access
CNChariklia Neophytou
Chariklia Neophytou
DSDimitra Sakellari
Dimitra Sakellari
IVIoannis Vouros
Ioannis Vouros
TSTheodora Slini
Theodora Slini
Serafeim C. ChaintoutisSerafeim C. Chaintoutis
Serafeim C. Chaintoutis
Konstantinos PapadimitriouKonstantinos Papadimitriou
Konstantinos Papadimitriou
Objective: To evaluate the clinical, microbiological, and patient-reported outcome measures (PROMs) of Er:YAG laser and photobiomodulation (PBM) therapy compared with conventional mechanical debridement (MD) in the nonsurgical treatment of peri-implantitis. Materials and Methods: Forty-five patients with peri-implantitis were randomly assigned to MD (control, n = 24) or Er:YAG laser followed by PBM (test, n = 21). Clinical parameters [probing depth (PD), bleeding on probing (BoP), clinical attachment level (CAL), plaque index, recession, suppuration] and levels of Porphyromonas gingivalis and Filifactor alocis were assessed at baseline and 3 months. Treatment success, defined as PD ≤ 5 mm, BoP at ≤ 1 site, and absence of suppuration, was assessed at 3 months. PROMs, including postoperative pain, analgesic use, anesthesia requirement, and satisfaction, were recorded during the first postoperative week. Results: Both groups showed significant clinical improvement ( p < 0.001). The laser group demonstrated greater reductions in PD (−2.30 vs. −1.45 mm, p < 0.001), BoP (−73.0% vs. −42.4%, p = 0.004), and CAL (−2.56 vs. −1.47 mm, p = 0.001), with higher treatment success (81% vs. 42%, p = 0.007). P. gingivalis decreased significantly only in the laser group ( p = 0.001), while F. alocis changes were not significant in both groups. PROMs favored the laser group, with lower postoperative pain, reduced analgesic use, and higher satisfaction ( p < 0.05). Conclusions: Adjunctive Er:YAG and PBM therapy improved clinical outcomes, reduced P. gingivalis , and enhanced patient experience compared with MD. Clinical Relevance: Er:YAG and PBM therapy may improve treatment success, enhance patient comfort, and support more predictable nonsurgical management of peri-implantitis.

10 November 2026 in Prosthesis
Verified
Journal Article
Open access
PDF file
GVGeorgia Vasileiadi
Georgia Vasileiadi
KSKatia Sarafidou
Katia Sarafidou
EXEvangelos Ximinis
Evangelos Ximinis
TSTheodora Slini
Theodora Slini
FGFotis Gogomitros
Fotis Gogomitros
ABAthina Bakopoulou
Athina Bakopoulou
Background/Objectives: This in vitro study evaluated the effect of PEEK scan body splinting on geometric scan-body measurements obtained from complete-arch digital implant scans using two intraoral scanners under two simulated clinical scenarios. Methods: Two 3D-printed edentulous maxillary models, each containing six implants at positions #16, #14, #12, #22, #24, and #26 (FDI notation), were evaluated. Model 1 contained parallel implants, whereas Model 2 included selected implants angulated 20° buccally or distally. Each model was scanned with the CS 3600 and TRIOS 3 under non-splinted (NSS) and PEEK-splinted (SS) conditions. Ten repeated scans were acquired per experimental condition (80 scans in total). After alignment to a common reference coordinate system, the scan-body longitudinal-axis vector magnitude (Vector, mm) and a composite angular metric (Δφ, °) were calculated at each implant position. Position-specific differences among NSS, SS, controlNSS, and controlSS groups were evaluated with Kruskal–Wallis tests followed, when appropriate, by Bonferroni-adjusted pairwise comparisons (α = 0.05). Results: Statistically significant NSS–SS differences were observed only at selected implant positions. For the CS 3600, significant differences involved Vector and/or Δφ, whereas for the TRIOS 3 they were confined to Δφ. In every statistically significant NSS–SS comparison, the SS group showed a lower mean value of the corresponding metric. More statistically significant NSS–SS differences were observed in Model 2 for the CS 3600 and in Model 1 for the TRIOS 3. These findings describe differences in the analyzed geometric metrics and should not be interpreted as direct test–reference trueness estimates. Conclusions: PEEK scan body splinting was associated with changes in scan-body geometric measurements at selected implant positions, but the effect was not uniform across scanners or experimental conditions. Because Vector and Δφ were not calculated as direct test–reference deviations, the present data do not establish improved trueness, precision, or overall scanning accuracy. Further studies using direct reference-based error metrics are required to determine clinical relevance.