Roya Peirovi-Minaee

Dr. Roya Peirovi-Minaee


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2024 in Food and Chemical Toxicology
Verified
Journal Article
Closed access
RPRoya Peirovi-Minaee
Roya Peirovi-Minaee
MTMahmoud Taghavi
Mahmoud Taghavi
MHMarzieh Harimi
Marzieh Harimi
AZAhmad Zarei
Ahmad Zarei

1 January 2019 in MethodsX
Verified
Journal Article
Open access
RPRoya Peirovi-Minaee
Roya Peirovi-Minaee
MAMojtaba Afsharnia
Mojtaba Afsharnia
AMAlireza Moghaddam
Alireza Moghaddam
AEAli Asghar Ebrahimi
Ali Asghar Ebrahimi
MAMohsen Askarishahi
Mohsen Askarishahi
MMMehdi Mokhtari
Mehdi Mokhtari
Chlorine reacts with both organic and inorganic matters in water. That is why water quality modeling has received great attention in recent years. The serious issue in municipal water quality modeling is gathering the essential input parameters of the model, particularly bulk decay (kb) and wall decay (kw) coefficients as well as their calibrations. Therefore, this study first thoroughly formulates the problem in the form of a heuristic optimization and then utilizes Genetic Algorithm, Particle Swarm Optimization, and Hybrid GA-PSO as the model optimizers in order to best calibrate kw for minimizing the difference of residual chlorine concentrations that exist between the simulated and observed values. These three algorithms are linked to EPANET, the hydraulic and water quality simulator. The method is then applied to a real-world water distribution network. Here, k w is considered as a decision variable. The objective function is to minimize both the Sum of Square Error and Root Mean Square Error between the observed and simulated chlorine concentrations. According to the simulation results obtained, the optimal value of wall decay coefficient is 1.233 m/day during the calibration process while the minimum and maximum differences between the measured and simulated chlorine rates were 0 and 0.18, respectively. •The method presented in this article can be useful for managers of water and wastewater companies, water resources facilities and operators and operation manager of water distribution system to manage chlorine dosing rate.•Due to adverse health effect of disinfection by product and poor microbial water quality as results of inefficient chlorination, control chlorine concentration in water distribution networks and its consequence on human health effect is necessary.•Hybrid PSO and GA methods are used to cope with their falling in local optimum and requiring highly computational effort.

19 February 2019 in Water Resources Management
Verified
Journal Article
Closed access
PDF file
RPRoya Peirovi-Minaee
Roya Peirovi-Minaee
MMMehdi Mokhtari
Mehdi Mokhtari
AMAlireza Moghaddam
Alireza Moghaddam
AEAli Asghar Ebrahimi
Ali Asghar Ebrahimi
MAMohsen Askarishahi
Mohsen Askarishahi
MAMojtaba Afsharnia
Mojtaba Afsharnia

29 May 2020 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
AMAlireza Moghaddam
Alireza Moghaddam
MAMojtaba Afsharnia
Mojtaba Afsharnia
RPRoya Peirovi-Minaee
Roya Peirovi-Minaee

13 April 2022 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
AMAlireza Moghaddam
Alireza Moghaddam
MAMojtaba Afsharnia
Mojtaba Afsharnia
MMMehdi Mokhtari
Mehdi Mokhtari
RPRoya Peirovi-Minaee
Roya Peirovi-Minaee

18 July 2022 in Drinking Water Engineering and Science
Verified
Journal Article
Open access
PDF file
AMAlireza Moghaddam
Alireza Moghaddam
AFAlireza Faridhosseini
Alireza Faridhosseini
HRHossein Rezaei
Hossein Rezaei
RPRoya Peirovi-Minaee
Roya Peirovi-Minaee
AZAli Naghi Ziaei
Ali Naghi Ziaei
In this research, reliability indicators of water distribution networks were evaluated under pipe failure conditions. The case studies included two benchmark networks and one real-life water distribution network in Iran with more hydraulic constraints. Some important reliability indicators were presented, such as resilience index, network resilience, modified resilience index, and minimum surplus head index. GANetXL was used to do the one-objective and two-objective optimization of the previously mentioned water distribution networks in order to not only minimize the cost but also maximize the reliability indicators. Moreover, the results of a statistical analysis for each pipe were used to determine the sensitive pipes that were of the most failure probability. GANetXL is an optimization tool in the Microsoft Excel environment and works based on a genetic algorithm. GANetXL has the capability of being linked to EPANET (hydraulic simulation software). The results obtained clearly showed that network resilience index was poor performance when compared with the other indexes under pipe failure conditions, especially in real-life networks that include small pipe diameters. It was also showed that if a water distribution network was optimized only in terms of cost, then there would be an unacceptable pressure drop at some nodes in case of pipe failure.