Feyza Özaltun

Dr. Feyza Özaltun


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
DGDilara Gocmen
Dilara Gocmen
YMYasemin MASATLIOĞLU
Yasemin MASATLIOĞLU
FÖFeyza Özaltun
Feyza Özaltun
ÖGÖmer Günal
Ömer Günal
TUTümay Umuroğlu
Tümay Umuroğlu
Background and Objectives: Patients with obesity undergoing laparoscopic bariatric surgery face elevated perioperative pulmonary risk due to impaired respiratory mechanics, reduced functional residual capacity, and pneumoperitoneum-induced atelectasis. Intraoperative changes in intra-abdominal pressure and surgical positioning substantially alter respiratory mechanics, yet studies evaluating repeated PEEP titration at multiple intraoperative time points remain limited. This study aimed to determine whether dynamic compliance-guided individualized PEEP titration, applied at three distinct intraoperative stages, reduces postoperative pulmonary aeration loss compared to fixed 8 cmH2O PEEP. Methods: In this single-center randomized controlled trial with blinded outcome assessment, 70 patients with obesity (BMI ≥ 35 kg/m2) undergoing laparoscopic bariatric surgery were randomized 1:1 to the CDYN group (dynamic compliance-guided PEEP titration at T1: post-induction, T2: during pneumoperitoneum, T3: post-deflation; n = 35) or the PEEP8 group (fixed PEEP 8 cmH2O; n = 35). The primary outcome was the modified lung ultrasound score (mLUSS), assessed 30 min after PACU arrival by a blinded investigator (ClinicalTrials.gov: NCT06994780). Results: Total mLUSS was significantly lower in the CDYN group (2.20 ± 1.16 vs. 5.80 ± 2.14; p < 0.001), with significant differences in both hemithoraces. The PaO2/FiO2 ratio at PACU was significantly higher in the CDYN group (425.11 ± 127.13 vs. 311.65 ± 92.59 mmHg; p < 0.001), and the supplemental oxygen requirement was significantly lower (p = 0.001). Dynamic compliance was consistently higher throughout surgery (all p < 0.001) without differences in airway pressures or hemodynamics. Conclusions: Dynamic compliance-guided individualized PEEP titration, applied at three intraoperative stages, significantly reduces early postoperative pulmonary aeration loss and improves oxygenation in patients with obesity undergoing laparoscopic bariatric surgery, without increasing barotrauma risk or hemodynamic instability.

27 October 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DGDilara Gocmen
Dilara Gocmen
FÖFeyza Özaltun
Feyza Özaltun
YMYasemin MASATLIOĞLU
Yasemin MASATLIOĞLU
CTCanan Topcu
Canan Topcu
TUTümay Umuroğlu
Tümay Umuroğlu
Purpose: Ultrasonographic optic nerve sheath diameter (ONSD) has been investigated as a noninvasive sonographic marker associated with intracranial pressure. This study aimed to compare the early change in ONSD after airway placement between children managed with an endotracheal tube (ETT) and those managed with a laryngeal mask airway (LMA). Methods: This single-center prospective, non-randomized observational study included 160 children stratified into age groups of 1–4 and 5–11 years, with 40 patients in each airway subgroup. Bilateral mean ONSD was measured before airway placement (T0), immediately after airway placement and initiation of mechanical ventilation (T1), and after airway removal but before full awakening (T2). The primary outcome was the between-device difference in the change in ONSD from T0 to T1. Repeated measurements were analyzed using a linear mixed-effects model, with Holm adjustment for multiple comparisons. Results: The increase in bilateral mean ONSD from T0 to T1 was 0.269 mm greater in the ETT group than in the LMA group (95% confidence interval [CI], 0.131–0.408; Holm-adjusted p < 0.001). The age-specific ETT–LMA difference in change was 0.293 mm in children aged 1–4 years (95% CI, 0.097–0.488; Holm-adjusted p = 0.0068) and 0.246 mm in those aged 5–11 years (95% CI, 0.050–0.442; Holm-adjusted p = 0.0137). The age group × airway device × time interaction was not significant (Holm-adjusted p = 0.743). In exploratory analyses, peak inspiratory and plateau pressures were higher in the ETT group in both age strata. Conclusions: In the early period after airway placement, ETT use was associated with a greater increase in bilateral mean ONSD than LMA use. Although the association was directionally consistent in both age strata, there was no evidence that the magnitude of the effect differed by age group. Because ONSD is not a direct measurement of intracranial pressure, these findings should not be interpreted as evidence of clinical intracranial hypertension or causality. The airway device was not randomized but was determined by surgical and clinical factors and the attending anesthesiologist’s judgment, and the clinical significance of the 0.269 mm difference is uncertain.