Inna Szekacs

Dr. Inna Szekacs

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MSMilan Sztilkovics
Milan Sztilkovics
TGTamas Gerecsei
Tamas Gerecsei
BPBeatrix Peter
Beatrix Peter
ASAndras Saftics
Andras Saftics
SKSandor Kurunczi
Sandor Kurunczi
Robert HorvathRobert Horvath
Robert Horvath
Single-cell adhesion force plays a crucial role in biological sciences, however its in-depth investigation is hindered by the extremely low throughput and the lack of temporal resolution of present techniques. While atomic force microcopy (AFM) based methods are capable of directly measuring the detachment force values between individual cells and a substrate, their throughput is limited to few cells per day, and cannot provide the kinetic evaluation of the adhesion force over the timescale of several hours. In this study a high spatial and temporal resolution resonant waveguide grating based label-free optical biosensor was combined with robotic fluidic force microscopy to monitor the adhesion of living cancer cells. In contrast to traditional fluidic force microscopy methods with a manipulation range in the order of 300–400 micrometers, the robotic device employed here can address single cells over mm-cm scale areas. This feature significantly increased measurement throughput, and opened the way to combine the technology with the employed microplate-based, large area biosensor. After calibrating the biosensor signals with the direct force measuring technology on 30 individual cells, the kinetic evaluation of the adhesion force and energy of large cell populations was performed for the first time. We concluded that the distribution of the single-cell adhesion force and energy can be fitted by log-normal functions as cells are spreading on the surface and revealed the dynamic changes in these distributions. The present methodology opens the way for the quantitative assessment of the kinetics of single-cell adhesion force and energy with an unprecedented throughput and time resolution, in a completely non-invasive manner.

10 February 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
BPBeatrix Peter
Beatrix Peter
EFEniko Farkas
Eniko Farkas
EFEniko Forgacs
Eniko Forgacs
ASAndras Saftics
Andras Saftics
BKBoglarka Kovacs
Boglarka Kovacs
Robert HorvathRobert Horvath
Robert Horvath
The interaction of the anti-adhesive coating, poly(L-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG) and its Arg-Gly-Asp (RGD) functionalized form, PLL-g-PEG-RGD, with the green tea polyphenol, epigallocatechin-gallate (EGCg) was in situ monitored. After, the kinetics of cellular adhesion on the EGCg exposed coatings were recorded in real-time. The employed plate-based waveguide biosensor is applicable to monitor small molecule binding and sensitive to sub-nanometer scale changes in cell membrane position and cell mass distribution; while detecting the signals of thousands of adhering cells. The combination of this remarkable sensitivity and throughput opens up new avenues in testing complicated models of cell-surface interactions. The systematic studies revealed that, despite the reported excellent antifouling properties of the coatings, EGCg strongly interacted with them, and affected their cell adhesivity in a concentration dependent manner. Moreover, the differences between the effects of the fresh and oxidized EGCg solutions were first demonstrated. Using a semiempirical quantumchemical method we showed that EGCg binds to the PEG chains of PLL-g-PEG-RGD and effectively blocks the RGD sites by hydrogen bonds. The calculations supported the experimental finding that the binding is stronger for the oxidative products. Our work lead to a new model of polyphenol action on cell adhesion ligand accessibility and matrix rigidity.

8 January 2009 in Applied Optics
Verified
Journal Article
Closed access
PDF file
András SzékácsAndrás Székács
András Székács
NANóra Adányi
Nóra Adányi
ISInna Szekacs
Inna Szekacs
KMKrisztina Majer-Baranyi
Krisztina Majer-Baranyi
ISIstván Szendrő
István Szendrő
Coupling the high specificity of the immunoanalytical reaction with the high sensitivity of optical wave guide light-mode spectroscopy (OWLS) detection gives the possibility to develop immunosensors with in most cases a definitely lower detection limit than traditionally used immunoassays. Measurements were performed on the sensitized surface of optical waveguide grating coupler sensors (2400  lines/mm grating). The OWLS technique is based on the precise measurement of the resonance angle of a polarized laser light (632.8 nm), diffracted by a grating and incoupled into a thin waveguide. The effective refractive index, determined from the resonance incoupling angle detected at high accuracy, allows determination of layer thickness and coverage (or mass) of the adsorbed or bound material with ultrahigh sensitivity. OWLS immunosensors were developed as label-free immunosensors with an amino group modified SiO2-TiO2 sensor surface on which the immunoreactants could be anchored. One of the components of the antibody–antigen complex was chemically bound on the sensor surface, allowing noncompetitive or competitive detection of the analytes. To illustrate that the resulting immunosensors are suitable for the determination of small and large molecular weight analytes, OWLS sensor formats were applied for quantitative detection of a herbicide active ingredient trifluralin, a Fusarium mycotoxin zearalenone, and an egg yolk protein of key importance in endocrine regulation, vitellogenin.

1 June 2011 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
ANA. Nabok
A. Nabok
ATA. Tsargorodskaya
A. Tsargorodskaya
MMM.K. Mustafa
M.K. Mustafa
ISInna Szekacs
Inna Szekacs
NSN.F. Starodub
N.F. Starodub
András SzékácsAndrás Székács
András Székács

1 June 2018 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
EFEniko Farkas
Eniko Farkas
András SzékácsAndrás Székács
András Székács
BKBoglarka Kovacs
Boglarka Kovacs
MOMarianna Olah
Marianna Olah
Robert HorvathRobert Horvath
Robert Horvath
ISInna Szekacs
Inna Szekacs

22 March 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
BPBeatrix Péter
Beatrix Péter
EFEniko Farkas
Eniko Farkas
SKSandor Kurunczi
Sandor Kurunczi
ZSZoltán Szittner
Zoltán Szittner
SBSzilvia Bősze
Szilvia Bősze
Robert HorvathRobert Horvath
Robert Horvath
Novel biosensors already provide a fast way to detect the adhesion of whole bacteria (or parts of them), biofilm formation, and the effect of antibiotics. Moreover, the detection sensitivities of recent sensor technologies are large enough to investigate molecular-scale biological processes. Usually, these measurements can be performed in real time without using labeling. Despite these excellent capabilities summarized in the present work, the application of novel, label-free sensor technologies in basic biological research is still rare; the literature is dominated by heuristic work, mostly monitoring the presence and amount of a given analyte. The aims of this review are (i) to give an overview of the present status of label-free biosensors in bacteria monitoring, and (ii) to summarize potential novel directions with biological relevancies to initiate future development. Optical, mechanical, and electrical sensing technologies are all discussed with their detailed capabilities in bacteria monitoring. In order to review potential future applications of the outlined techniques in bacteria research, we summarize the most important kinetic processes relevant to the adhesion and survival of bacterial cells. These processes are potential targets of kinetic investigations employing modern label-free technologies in order to reveal new fundamental aspects. Resistance to antibacterials and to other antimicrobial agents, the most important biological mechanisms in bacterial adhesion and strategies to control adhesion, as well as bacteria-mammalian host cell interactions are all discussed with key relevancies to the future development and applications of biosensors.