Zbigniew Orski

Dr. Zbigniew Orski

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
MKMaciej Kempa
Maciej Kempa
APAndrzej Przybylski
Andrzej Przybylski
SBSzymon Budrejko
Szymon Budrejko
TFTomasz Fabiszak
Tomasz Fabiszak
MLMichał Lewandowski
Michał Lewandowski
SBSerge Boveda
Serge Boveda
The implantation of a subcutaneous cardioverter-defibrillator (S-ICD) may be used instead of a traditional transvenous system to prevent sudden cardiac death. Our aim was to compare the characteristics of S-ICD patients from the multi-center registry of S-ICD implantations in Poland with the published results of the European Snapshot Survey on S-ICD Implantation (ESSS-SICDI). We compared data of 137 Polish S-ICD patients with 68 patients from the ESSS-SICDI registry. The groups did not differ significantly in terms of sex, prevalence of ischemic cardiomyopathy, concomitant diseases, and the rate of primary prevention indication. Polish patients had more advanced heart failure (New York Heart Association (NYHA) class III: 11.7% vs. 2.9%, NYHA II: 48.9% vs. 29.4%, NYHA I: 39.4% vs. 67.7%, p < 0.05 each). Young age (75.9% vs. 50%, p < 0.05) and no vascular access (7.3% vs. 0%, p < 0.05) were more often indications for S-ICD. The percentage of patients after transvenous system removal due to infections was significantly higher in the Polish group (11% vs. 1.5%, p < 0.05). In the European population, S-ICD was more frequently chosen because of patients’ active lifestyle and patients’ preference (both 10.3% vs. 0%, p < 0.05). Our analysis shows that in Poland, compared to other European countries, subcutaneous cardioverters-defibrillators are being implanted in patients at a more advanced stage of chronic heart failure. The most frequent reason for choosing a subcutaneous system instead of a transvenous ICD is the young age of a patient.

24 September 2026 in Biomedicines
Verified
Journal Article
Open access
PDF file
MDMartyna Dąbrowska
Martyna Dąbrowska
MPMagdalena Potapowicz-Krysztofiak
Magdalena Potapowicz-Krysztofiak
PZPatrycja Zyczkowska
Patrycja Zyczkowska
MMMałgorzata Maciorowska
Małgorzata Maciorowska
ZOZbigniew Orski
Zbigniew Orski
Beata Uziębło-ŻyczkowskaBeata Uziębło-Życzkowska
Beata Uziębło-Życzkowska
Background: Mechanical dispersion of left ventricular contraction reflects electromechanical heterogeneity and may contribute to arrhythmogenesis. We evaluated whether myocardial work dispersion is associated with ventricular arrhythmia (VA) risk in patients with heart failure with reduced ejection fraction (HFrEF). Methods: Eighty-five patients with HFrEF and no history of atrial fibrillation of any type and with complete arrhythmia follow-up (mean age 65 ± 12 years, 83.5% male, mean LVEF 30.5 ± 6.6%) underwent echocardiography one day before elective implantable cardioverter-defibrillator (ICD) or cardiac resynchronisation therapy (CRT) implantation and were followed for one year. Results: VAs—sustained or non-sustained ventricular tachycardia, or ventricular fibrillation—occurred in 32.9% of patients. Myocardial work index (MWI) dispersion, expressed as standard deviation (SD) or Range, showed the highest single-parameter discrimination (AUC 0.848 and 0.859). Models combining MWI dispersion with right atrial (RA) area performed best (AUC 0.912 and 0.911). In multivariable logistic regression, both MWI dispersion and RA area were independently associated with VAs; odds ratios per 10-unit increase were 1.116 for MWI dispersion (SD), 1.030 for MWI dispersion (Range) and 1.276 per 1 cm2 of RA area. Conclusions: In this cohort, MWI dispersion showed the highest single-parameter discrimination for VAs among the echocardiographic variables tested, and its combination with RA area gave the best model. The two variables were independently associated with VAs in the same model. These exploratory findings are hypothesis-generating and require external validation before clinical application.

9 September 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MDMartyna Dąbrowska
Martyna Dąbrowska
MPMagdalena Potapowicz-Krysztofiak
Magdalena Potapowicz-Krysztofiak
MKMarek Kiliszek
Marek Kiliszek
ZOZbigniew Orski
Zbigniew Orski
MSMagdalena Maria Smalc-Stasiak
Magdalena Maria Smalc-Stasiak
Beata Uziębło-ŻyczkowskaBeata Uziębło-Życzkowska
Beata Uziębło-Życzkowska
Background: Heart failure with reduced ejection fraction (HFrEF) may be caused by various factors. The etiology of HFrEF may influence prognosis and further management. Objectives: In this study we aimed to assess differences between ischemic and non-ischemic etiology in the context of clinical features, hemodynamic evaluation, and left ventricular (LV) and left atrial (LA) remodeling in a selected cohort of patients referred for device implantation. Methods: This prospective single-center study included 86 patients with HFrEF in sinus rhythm, without a history of atrial fibrillation, referred for ICD or CRT implantation. All patients underwent comprehensive echocardiography, electrocardiography, impedance cardiography and laboratory testing. This was a cross-sectional analysis without clinical follow-up. The pre-specified question was whether the two etiological groups differed in LV remodeling and LA function. All regression analyses were exploratory. Guideline-directed medical therapy was recorded in all patients. Results: Among 86 patients, 58 had ischemic and 28 had non-ischemic HFrEF. Patients with ischemic etiology were older, had worse renal function, and had higher N-terminal pro–B-type natriuretic peptide levels. They also exhibited lower left ventricular mass index (LVMI), left atrial reservoir strain (LASr), left atrial emptying fraction (LAEF), and higher left atrial stiffness index (LASI). Among myocardial work parameters, only global wasted work (GWW) differed significantly, with higher values in the non-ischemic group. Patients with ischemic HFrEF also had a higher Heather index (HI) in impedance cardiography. The two groups did not differ in guideline-directed medical therapy. In univariable logistic regression, older age, lower LVMI, reduced LASr and LAEF, higher LASI, higher HI, and lower eGFR were associated with ischemic HFrEF etiology. In the multivariable model, older age, lower LVMI, and reduced LASr remained independently associated with ischemic HFrEF (area under the ROC curve 0.82). Conclusions: Patients with ischemic and non-ischemic HFrEF referred for device implantation differ in LV remodeling and LA function. The between-group differences were small in absolute terms, with widely overlapping distributions, and the study was not designed to test whether echocardiography can replace established methods of establishing HFrEF etiology. These exploratory findings are hypothesis-generating and require confirmation in larger, independent cohorts.

21 April 2026 in Biomedicines
Verified
Journal Article
Open access
PDF file
MPMagdalena Potapowicz-Krysztofiak
Magdalena Potapowicz-Krysztofiak
MDMartyna Dąbrowska
Martyna Dąbrowska
MMMałgorzata Maciorowska
Małgorzata Maciorowska
ZOZbigniew Orski
Zbigniew Orski
Paweł KrzesińskiPaweł Krzesiński
Paweł Krzesiński
Beata Uziębło-ŻyczkowskaBeata Uziębło-Życzkowska
Beata Uziębło-Życzkowska
Background: Left bundle branch block (LBBB) and QRS prolongation are markers of electrical dyssynchrony in heart failure, but they do not fully reflect its mechanical consequences. Myocardial work (MW)-derived indices may provide a more comprehensive assessment of left ventricular (LV) mechanical dyssynchrony. We evaluated associations between LV MW parameters, QRS duration, and LBBB in patients with heart failure with reduced ejection fraction (HFrEF) referred for ICD/CRT implantation. Methods: In this single-centre observational cross-sectional study, 96 consecutive patients referred for ICD or CRT implantation were screened. All patients underwent standardized baseline comprehensive echocardiography followed by advanced MW analysis. Myocardial work index (MWI) dispersion was assessed using two complementary methods. MWI dispersion (SD) was calculated as the standard deviation of segmental MWI values across all LV segments, and MWI dispersion (IQR) was defined as the interquartile range (IQR) of segmental MWI values. We evaluated the associations between QRS duration and MW-derived dyssynchrony parameters (individual and composite), as well as their discriminative performance for LBBB. Seven patients were excluded from further analysis due to inadequate echocardiography image quality. Results: The final study group comprised 89 patients with HFrEF (median age 65.5 years), of whom 67.4% were assigned to CRT. LBBB was present in 41.6%, and the median QRS duration was 142 ms (112–162). All analyzed LV MW indices were significantly associated with QRS duration (all q < 0.01). The strongest correlations were observed for MWI dispersion (IQR) (r = 0.58), peak strain dispersion (PSD) (r = 0.54), lateral–septal work asymmetry (r = 0.53), and MWI dispersion (SD) (r = 0.52) (all q < 0.0001). All MW indices differed significantly between patients with and without LBBB (all q ≤ 0.0001). MWI dispersion (IQR) showed the best single-marker discrimination of LBBB (AUC = 0.852). Composite indices achieved AUC = 0.84 but did not significantly improve discrimination versus MWI dispersion (IQR) alone. Conclusions: Myocardial work-derived indices of left ventricular dyssynchrony are strongly associated with QRS duration and the presence of LBBB in patients with HFrEF. Among them, MWI dispersion (IQR) was shown to be the best-performing MW marker for identifying LBBB. These findings suggest that MW dispersion may serve as a robust echocardiographic marker of mechanical dyssynchrony and warrants further investigation as a potential tool for predicting CRT response.