Haibing Cong

Haibing Cong


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Journal of Environmental Management
Verified
Journal Article
Closed access
FSFeng Sun
Feng Sun
FWFengyi Wang
Fengyi Wang
HJHuanglin Jiang
Huanglin Jiang
QHQinyun Huang
Qinyun Huang
CXChenhui Xu
Chenhui Xu
HCHaibing Cong
Haibing Cong

16 December 2006 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
THTinglin Huang
Tinglin Huang
HCHaibing Cong
Haibing Cong

21 January 2022 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
FSFeng Sun
Feng Sun
SYShuo Ye
Shuo Ye
CXChenhui Xu
Chenhui Xu
FWFengyi Wang
Fengyi Wang
PYPeng Yu
Peng Yu
HCHaibing Cong
Haibing Cong
The characteristic analysis of cyanobacterial organic matters is an important premise of cyanobacterial organic pollution control. This paper investigated the component structure characteristics of algal organic matters (AOM) secreted and released by cyanobacteria in laboratory culture and actual Taihu Lake environment by spectroscopic quantitative and qualitative methods. Results showed that the secretion amount of AOM was mainly 4–6 μg COD/106 cells during the growth period of Microcystis aeruginosa, and the content ratio of extracellular organic matters (EOM) to intracellular organic matters (IOM) gradually increased from 0.83 in adaptation and logarithmic period to 3.33 in stable and decay period. The secretion of IOM showed a decrease trend, which indicated the decrease of its synthesis or the gradual infiltration and loss caused by cell membrane damage. From the component characteristics, the EOM had lower SUVA value and higher proportion of small molecular substances with molecular weight <3 kDa, indicating its more difficult to separate from water than IOM. Compared with the laboratory culture environment, the actual Taihu Lake resulted in more obvious characteristic heterogeneity of cyanobacteria EOM and IOM.

1 June 2011 in Journal of Hydraulic Engineering
Verified
Journal Article
Closed access
HCHaibing Cong
Haibing Cong
THTinglin Huang
Tinglin Huang
BCBeibei Chai
Beibei Chai
Thermal stratification is a common phenomenon in deep lakes and reservoirs, which often results in water-quality deterioration, including such problems as hypolimnetic anoxia, the release of pollutants from sediments, and algal blooms. Hypolimnetic oxygenation and destratification are the two commonly used methods for resolving these water-quality problems. A new water-quality improvement device, the water-circulating aerator, was designed to destratify lakes and reservoirs, by circulation and oxygenation of upper and lower layers of water. The design of the structure of the water-circulating aerator is detailed. Three mathematical models were built to optimize this structure, estimate the rate of water flow in the aerator, and calculate the rate of oxygen transfer from air bubbles to water in the aerator. These models were verified by experiments. The water-circulating aerator system has been successfully applied in a stratified reservoir to increase dissolved oxygen to reduce the releasing of ammonia-ni...

17 March 2017 in Environmental Technology
Verified
Journal Article
Closed access
HCHaibing Cong
Haibing Cong
FSFeng Sun
Feng Sun
WCWenjing Chen
Wenjing Chen
YXYajun Xu
Yajun Xu
WWWei Wang
Wei Wang
In order to effectively remove the Microcystis from drinking-water sources, pre-pressure treatment was first used to make the Microcystis lose buoyancy, and then it is easily removed by coagulation and sedimentation processes. The Microcystis-containing water from Taihu Lake was taken for the pre-pressure coagulation and sedimentation treatments in this study. Both intermittent laboratory experiment and continuous-flow field experiment were conducted. Experimental results showed that the optimum pre-pressure condition was pressuring at 0.6–0.8 MPa for at least 10 s, and 60 s was the best. Comparing with the pre-oxidation, pre-pressure could obviously increase the removal efficiency of Microcystis by following coagulation and sedimentation, and would not increase the dissolved microcystins. The mechanism of pre-pressure treatment was that the pre-pressure destroys the gas vesicles in Microcystis cells and the gas diffuses out of the cells, which leads the Microcystis to lose buoyancy and make them to sink. The recovery time of gas vesicles was longer than the sludge discharge period of sedimentation tank; therefore, the sinking Microcystis would not re-float in the sedimentation tank. In the practical application of drinking water treatment plant, the continuous-flow pressure device could be chosen, with the energy consumption of about 22.9 kw·h per 10,000 m3. GRAPHICAL ABSTRACT

1 December 2019 in Journal of Environmental Engineering
Verified
Journal Article
Closed access
FSFeng Sun
Feng Sun
HCHaibing Cong
Haibing Cong
XJXinyue Jiang
Xinyue Jiang
WCWenjing Chen
Wenjing Chen
SXSitao Xu
Sitao Xu
YLYujiao Liu
Yujiao Liu
Water quality is a critical factor in the treatment of Microcystis aeruginosa–contaminated water sources. In this paper, we report on a pressure pretreatment method that is safer than the traditional preoxidation treatment for the removal of Microcystis aeruginosa from water obtained from Taihu Lake in China. The experimental results indicated that the removal efficiency of Microcystis aeruginosa was significantly improved when the water was pressurized at 0.3–0.7 MPa for 1 min, and the optimal removal efficiency was obtained at a pressure of 0.7 MPa. The removal efficiency of Microcystis aeruginosa by direct coagulation and sedimentation without a pretreatment was only 56.3%, whereas the pretreatments of 2  mg·L−1 chlorine oxidation for 30 min, 2  mg·L−1 KMnO4 oxidation for 30 min, and a prepressure treatment at 0.7 MPa for 1 min resulted in an increase in the removal efficiency to 68.4%, 72.1%, and 90.5%, respectively. The chlorine preoxidation increased the concentrations of the microcystins, dissolved organic carbon (DOC), and disinfection byproducts of the treated water; the KMnO4 preoxidation slightly increased the DOC and byproducts of the treated water; whereas the prepressure treatment did not increase the microcystin concentration but reduced the concentrations of the DOC and disinfection byproducts in the treated water. Therefore, the relative ranking of the methods in terms of water quality based on the concentration change of the microcystins, DOC, and byproducts following treatment was prepressure coagulation and sedimentation (PCS) > direct coagulation and sedimentation without a pretreatment (CS) > KMnO4 preoxidation coagulation and sedimentation (KMnO4 OCS) > chlorine preoxidation coagulation and sedimentation (chlorine OCS).