Chi Zhu

Chi Zhu


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
CLChang Liu
Chang Liu
Hongbo LiangHongbo Liang
Hongbo Liang
NUNaoya Ueda
Naoya Ueda
PLPeirang Li
Peirang Li
YFYasutaka Fujimoto
Yasutaka Fujimoto
CZChi Zhu
Chi Zhu
A power-assisted exoskeleton should be capable of reducing the burden on the wearer’s body or rendering his or her work improved and efficient. More specifically, the exoskeleton should be easy to wear, be simple to use, and provide power assistance without hindering the wearer’s movement. Therefore, it is necessary to evaluate the backdrivability, range of motion, and power-assist capability of such an exoskeleton. This evaluation identifies the pros and cons of the exoskeleton, and it serves as the basis for its subsequent development. In this study, a lightweight upper-limb power-assisted exoskeleton with high backdrivability was developed. Moreover, a motion capture system was adopted to measure and analyze the workspace of the wearer’s upper limb after the exoskeleton was worn. The results were used to evaluate the exoskeleton’s ability to support the wearer’s movement. Furthermore, a small and compact three-axis force sensor was used for power assistance, and the effect of the power assistance was evaluated by means of measuring the wearer’s surface electromyography, force, and joint angle signals. Overall, the study showed that the exoskeleton could achieve power assistance and did not affect the wearer’s movements.

3 December 2020 in Advanced Robotics
Verified
Journal Article
Closed access
LCLiu Chang
Liu Chang
HLHongbo Liang
Hongbo Liang
YMYoshitaka Murata
Yoshitaka Murata
PLPeirang Li
Peirang Li
NUNaoya Ueda
Naoya Ueda
CZChi Zhu
Chi Zhu
In this paper, a novel wearable lightweight exoskeleton with full degrees of freedom for upper-limb power assistance is developed. It is controlled by surface electromyography(sEMG) signals of the agonist muscle alone and aims to provide 30% power assistance to the elbow and shoulder joints for the flexion/extension movement. In the exoskeleton, there are two wearable identical arms and a back support pack. Each arm consists of two active joints and four passive joints, in which the active joints implement the power assistance for flexion/extension movement of the elbow and shoulder joints, whereas the passive joints fully follow the wearer's other motions. Moreover, with a rotatable and telescopic mechanism, the joint axis of the elbow joint of the exoskeleton can be adjusted to coincide with the elbow joint for different wearers, and meanwhile the passive joints of the shoulder complex of the exoskeleton can guarantee its instantaneous center of rotation to coincide with that of the wearer. As a result, the developed exoskeleton eliminates the restriction of motion and then the discomfort of the wearer. In addition, an extended admittance control is introduced and the effectiveness of the power assistance is verified. GRAPHICAL ABSTRACT

10 November 2020 in Symmetry
Verified
Journal Article
Open access
PDF file
Hongbo LiangHongbo Liang
Hongbo Liang
YYYingxin Yu
Yingxin Yu
MMMika Mochida
Mika Mochida
CLChang Liu
Chang Liu
NUNaoya Ueda
Naoya Ueda
CZChi Zhu
Chi Zhu
Brain–Machine Interfaces (BMIs) have attracted much attention in recent decades, mainly for their applications involving severely disabled people. Recently, research has been directed at enhancing the ability of healthy people by connecting their brains to external devices. However, there are currently no successful research reports focused on robotic power augmentation using electroencephalography (EEG) signals for the shoulder joint. In this study, a method is proposed to estimate the shoulder’s electromyography (EMG) signals from EEG signals based on the concept of a virtual flexor–extensor muscle. In addition, the EMG signal of the deltoid muscle is used as the virtual EMG signal to establish the EMG estimation model and evaluate the experimental results. Thus, the shoulder’s power can be augmented by estimated virtual EMG signals for the people wearing an EMG-based power augmentation exoskeleton robot. The estimated EMG signal is expressed via a linear combination of the features of EEG signals extracted by Independent Component Analysis, Short-time Fourier Transform, and Principal Component Analysis. The proposed method was verified experimentally, and the average of the estimation correlation coefficient across different subjects was 0.78 (±0.037). These results demonstrate the feasibility and potential of using EEG signals to provide power augmentation through BMI technology.

26 November 2014 in Robotics and Biomimetics
Verified
Journal Article
Open access
PDF file
MYMasataka Yoshioka
Masataka Yoshioka
CZChi Zhu
Chi Zhu
KIKazuyuki Imamura
Kazuyuki Imamura
FWFeng Wang
Feng Wang
HYHaoyong Yu
Haoyong Yu
YYYuling Yan
Yuling Yan
Aiming to develop an noninvasive BMI control system with EEG (electroencephalogram) signals to control external devices such as prostheses and robots for rehabilitation and/or power support, four different tasks corresponding to different brain excitation degrees are designed. Their EEG spectra are analyzed with short-time fast Fourier transform (STFFT), and their features of mu and beta rhythms corresponding to the different tasks are extracted. The extracted features are used to control a one-joint robot arm and their corresponding results are compared. The results show that the EEG signal when a subject is holding a weight is comparatively more stable than the EEG signals in other tasks such as motor imagery. This implies an effective way for power assist by EEG signals.

24 December 2018 in Bioengineering
Verified
Journal Article
Open access
PDF file
Hongbo LiangHongbo Liang
Hongbo Liang
CZChi Zhu
Chi Zhu
YIYu Iwata
Yu Iwata
SMShota Maedono
Shota Maedono
MMMika Mochita
Mika Mochita
FDFeng DUAN
Feng DUAN
Brain-Machine Interface (BMI) has been considered as an effective way to help and support both the disabled rehabilitation and healthy individuals’ daily lives to use their brain activity information instead of their bodies. In order to reduce costs and control exoskeleton robots better, we aim to estimate the necessary torque information for a subject from his/her electroencephalography (EEG) signals when using an exoskeleton robot to perform the power assistance of the upper limb without using external torque sensors nor electromyography (EMG) sensors. In this paper, we focus on extracting the motion-relevant EEG signals’ features of the shoulder joint, which is the most complex joint in the human’s body, to construct a power assistance system using wearable upper limb exoskeleton robots with BMI technology. We extract the characteristic EEG signals when the shoulder joint is doing flexion and extension movement freely which are the main motions of the shoulder joint needed to be assisted. Independent component analysis (ICA) is used to extract the source information of neural components, and then the average method is used to extract the characteristic signals that are fundamental to achieve the control. The proposed approach has been experimentally verified. The results show that EEG signals begin to increase at 300–400 ms before the motion and then decrease at the beginning of the generation of EMG signals, and the peaks appear at about one second after the motion. At the same time, we also confirmed the relationship between the change of EMG signals and the EEG signals on the time dimension, and these results also provide a theoretical basis for the delay parameter in the linear model which will be used to estimate the necessary torque information in future. Our results suggest that the estimation of torque information based on EEG signals is feasible, and demonstrate the potential of using EEG signals via the control of brain-machine interface to support human activities continuously.

9 April 2021 in Entropy
Verified
Journal Article
Open access
PDF file
Hongbo LiangHongbo Liang
Hongbo Liang
SMShota Maedono
Shota Maedono
YYYingxin Yu
Yingxin Yu
CLChang Liu
Chang Liu
NUNaoya Ueda
Naoya Ueda
CZChi Zhu
Chi Zhu
Electroencephalography neurofeedback (EEG-NFB) training can induce changes in the power of targeted EEG bands. The objective of this study is to enhance and evaluate the specific changes of EEG power spectral density that the brain-machine interface (BMI) users can reliably generate for power augmentation through EEG-NFB training. First, we constructed an EEG-NFB training system for power augmentation. Then, three subjects were assigned to three NFB training stages, based on a 6-day consecutive training session as one stage. The subjects received real-time feedback from their EEG signals by a robotic arm while conducting flexion and extension movement with their elbow and shoulder joints, respectively. EEG signals were compared with each NFB training stage. The training results showed that EEG beta (12–40 Hz) power increased after the NFB training for both the elbow and the shoulder joints’ movements. EEG beta power showed sustained improvements during the 3-stage training, which revealed that even the short-term training could improve EEG signals significantly. Moreover, the training effect of the shoulder joints was more obvious than that of the elbow joints. These results suggest that NFB training can improve EEG signals and clarify the specific EEG changes during the movement. Our results may even provide insights into how the neural effects of NFB can be better applied to the BMI power augmentation system and improve the performance of healthy individuals.