Feng Qiao

Dr. Feng Qiao


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2015 in Injury
Verified
Journal Article
Closed access
FQFeng Qiao
Feng Qiao
DLDichen Li
Dichen Li
ZJZhongmin Jin
Zhongmin Jin
YGYongchang Gao
Yongchang Gao
TZTao Zhou
Tao Zhou
LCLi Cheng
Li Cheng

4 August 2015 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
FQFeng Qiao
Feng Qiao
DLDichen Li
Dichen Li
ZJZhongmin Jin
Zhongmin Jin
DHDingjun Hao
Dingjun Hao
YLYonghua Liao
Yonghua Liao
SGSihai Gong
Sihai Gong

1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
HLHongwei Li
Hongwei Li
DLDichen Li
Dichen Li
FQFeng Qiao
Feng Qiao
LTLei Tang
Lei Tang
QHQi Han
Qi Han
External fixation is a long‐standing but well‐established method, which has been widely used for the treatment of fractures. To obtain the maximum benefit from the mechanical stimulus, the stiffness of the external fixator should be adjusted properly throughout the treatment phase. Nevertheless, the lack of a valid dynamic adjustable fixation device impedes this possibility. Based on the stiffness adjustment tolerance of the healing callus, this paper proposes an active‐dynamic stiffness adjustable external fixator design method to meet stiffness requirements at different stages of the tibial fracture healing process. A novel external fixator with an adjustable stiffness configuration was designed, and the finite element method was used to simulate the stress distribution between fixator and fracture gap. The stiffness adjustment tolerance was determined based on previous studies. According to this tolerance, the optimal block structure dismantling sequence was sought and the corresponding stiffness was calculated through topology optimization for the entire external fixator model. The appropriate amount of variable stiffness at the fracture gap was applied by dismantling the configuration of the block structure external fixator during the healing process. A novel patient‐specific adjustable stiffness external fixator for mechanically stimulated tibial fracture reduction and therapy was proposed. This enables surgeons to tailor the construction of the external fixator frame to the clinical needs of each patient. The presented dismantling approach of the block structure to produce conformable stiffness provides a new clinical treatment strategy for tibial fractures.

6 January 2023 in Frontiers in Surgery
Verified
Journal Article
Open access
YLYufeng Lu
Yufeng Lu
XWXue Wang
Xue Wang
BYBo Yang
Bo Yang
ZXZhaochen Xu
Zhaochen Xu
BZBaogang Zhang
Baogang Zhang
FQFeng Qiao
Feng Qiao
Purpose: Open-wedge high tibial osteotomy (HTO) is a common surgical treatment for medial osteoarthritis in young and active patients. The accuracy of osteotomy is closely associated with postoperative efficacy. The accuracy of digital preoperative planning is higher than that of the preoperative manual measurement and several computer software with varying accuracy and convenience are used for digital preoperative planning. This study aimed to use the SolidWorks software for HTO preoperative planning and to determine its accuracy and reliability in HTO preoperative planning.Methods: We reviewed the data of 28 patients with 54 with medial compartment knee arthritis who underwent open-wedge HTO preoperative planning using SolidWorks between June 2019 and March 2021. The standard anteroposterior standing whole-leg radiographs were assessed before and 6 weeks after the surgery. The correction angle, weight-bearing line (WBL) ratio, mechanical femorotibial angle (mFTA), and medial proximal tibial angle (MPTA) before and after the surgery were compared. The clinical results were evaluated using the Knee Society score.Results: At 6 weeks after the surgery, the WBL ratio was corrected from 16.8% to 50.5%, mFTA was corrected from 6.4° varus to 1.2° valgus, and MPTA was corrected from 83.4° to 89.3°. No significant difference was observed between the predicted correction angle before the surgery and the correction angle measured 6 weeks after the surgery (t = −1.745, p = 0.087). The knee score and function score of Knee Society increased from 76.4 and 80.7 before surgery to 95.0 and 95.7, respectively.Conclusions: The SolidWorks software showed high accuracy and reliability in preoperative planning of open-wedge HTO in patients with medial compartment knee arthritis.

27 January 2023 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
SLShu-Guang Liu
Shu-Guang Liu
DYDeng-Jie Yu
Deng-Jie Yu
HLHui Li
Hui Li
MOMichael Opoku
Michael Opoku
JLJun Li
Jun Li
FQFeng Qiao
Feng Qiao
Background: Severe knee valgus/varus or complex multiplanar deformities are common in clinic. If not corrected in time, cartilage wear will be aggravated and initiate the osteoarthritis due to lower limb malalignment. Internal fixation is unable to correct severe complex deformities, especially when combined with lower limb discrepancy (LLD). Based on the self-designed digital six-axis external fixator Q spatial fixator (QSF), which can correct complex multiplanar deformities without changing structures, accuracy of correction can be improved significantly. Methods: This retrospective study included 24 patients who suffered from complex knee deformity with LLD treated by QSF and internal fixation at our institution from January 2018 to February 2021. All patients had a closing wedge distal femoral osteotomy with internal fixation for immediate correction and high tibia osteotomy with QSF fixation for postoperative progressive correction. Data of correction prescriptions were computed by software from postoperative CT scans. Results: Mean discrepancy length of operative side was 2.39 ± 1.04 cm (range 0.9–4.4 cm) preoperatively. The mean difference of lower limb was 0.32 ± 0.13 cm (range 0.11–0.58 cm) postoperatively. The length of limb correction had significant difference (p < 0.05). The mean MAD and HKA decreased significantly (p < 0.05), and the mean MPTA and LDFA increased significantly (p < 0.05). There were significant increase (p < 0.05) in the AKSS-O, AKSS-F and Tegner Activity Score. The lower limb alignment was corrected (p < 0.05). The mean time of removing external fixator was 112.8 ± 17.9 days (range 83–147 days). Conclusions: Complex knee deformity with LLD can be treated by six-axis external fixator with internal fixation without total knee arthroplasty. Lower limb malalignment and discrepancy can be corrected precisely and effectively by this approach.

26 July 2022 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
HLHongwei Li
Hongwei Li
ZYZhangkai Yang
Zhangkai Yang
DLDichen Li
Dichen Li
FQFeng Qiao
Feng Qiao
Early onset scoliosis (EOS) is a type of spine deformity that presents before 10 years of age. The biomechanical properties in scoliosis have been found to be different, especially in the case of the concave and convex paravertebral muscles. Based on this fact, a novel three-dimensional (3D) printed patient-specific asymmetric stiffness brace design method is proposed in this paper, aiming to provide asymmetric stiffness to match “imbalanced” biomechanical properties of the concave and convex paravertebral muscles, respectively, and treat EOS by applying the block-structure brace. A 3D computer aided design draft model of the brace contour was implemented from 3D scanning. The asymmetric stiffness block-structure brace was designed in Rhinoceros and the finite element (FE) model was imported into abaqus. FE simulation was employed to study the mechanical characteristics of the brace, which provided a quantitative index for the imbalanced property of brace stiffness. The results of the FE simulation showed that the stiffnesses of the concave and convex sides were 145.88 N/mm and 35.95 N/mm, respectively. The block-structure brace was fabricated using 3D printing. Asymmetric stiffness was evaluated by corrective force measurements, which were obtained from a thin-film pressure sensor equipped on the brace. The patient-specific asymmetric stiffness brace was applied to clinical practice in a one-year-old EOS patient. A novel low-cost 3D printed brace design method for EOS was proposed in this study that could potentially be useful in patient treatment acceptance.