EREN ONUR KARAVİN

EREN ONUR KARAVİN

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2025 in The Journal of Emergency Medicine
Verified
Journal Article
Closed access
MAMustafa Altun
Mustafa Altun
Emre KuduEmre Kudu
Emre Kudu
FYFurkan Yakin
Furkan Yakin
MKMehmet Birkan Korgan
Mehmet Birkan Korgan
EUEmir Unal
Emir Unal
HAHaldun Akoglu
Haldun Akoglu

18 August 2026 in Turkish Journal of Cerebrovascular Diseases
Verified
Journal Article
Open access
PDF file
EUEmir Unal
Emir Unal
NBNURSELİ BAYRAM
NURSELİ BAYRAM
AKAhmet Enes Küçükardalı
Ahmet Enes Küçükardalı
EKEREN ONUR KARAVİN
EREN ONUR KARAVİN
EAErhan Altunbaş
Erhan Altunbaş
AAArzu Denizbasi Altinok
Arzu Denizbasi Altinok
Objective: Hemorrhagic transformation (HT) is a clinically significant complication of intravenous thrombolysis (IVT) in acute ischemic stroke, carrying substantial morbidity in its parenchymal subtypes. We evaluated and compared the diagnostic accuracy of the HAT, SEDAN, and HALP scores for predicting post-IVT HT. Materials and Methods: This retrospective single-center diagnostic accuracy study (STARD 2015) enrolled 317 consecutive IVT-treated acute ischemic stroke patients (January 2023–January 2026). The reference standard was any HT on follow-up non-contrast CT. ROC-derived AUC with 95% confidence intervals (DeLong method) was the primary accuracy measure; optimal cut-offs were determined by the Youden index; pairwise comparisons used the DeLong method. Results: Fifty-seven patients (18.0%) developed HT. The SEDAN score achieved the highest AUC (0.745; 95% CI 0.675–0.810), followed by HAT (0.721; 95% CI 0.653–0.790); the HALP score showed no meaningful discriminatory value (AUC 0.527; 95% CI 0.440–0.617). At the Youden-optimal cut-off of ≥ 2, the SEDAN score attained a sensitivity of 80.4%, a specificity of 60.8%, and a negative predictive value (NPV) of 93.4%. No significant AUC difference was detected between HAT and SEDAN (ΔAUC = –0.022; P = .826). Conclusions: The SEDAN score demonstrated the highest diagnostic accuracy for post-IVT HT prediction, with statistically indistinguishable performance versus HAT (95% CI for ΔAUC: –0.222 to +0.177); formal equivalence was not established. The HALP score provided no clinically meaningful discrimination. A SEDAN score below 2 may identify low-risk patients at the bedside. The high mechanical thrombectomy rate in HT-positive patients (71.9%) warrants cautious interpretation. Prospective multicenter validation is needed.

22 August 2026 in The American Journal of Emergency Medicine
Verified
Journal Article
Closed access
EUEmir Unal
Emir Unal
EAErhan Altunbaş
Erhan Altunbaş
EKEREN ONUR KARAVİN
EREN ONUR KARAVİN
MAMustafa Altun
Mustafa Altun
Emre KuduEmre Kudu
Emre Kudu
AAArzu Denizbasi Altinok
Arzu Denizbasi Altinok

17 October 2026 in Medicina
Verified
Journal Article
Open access
PDF file
EUEmir Unal
Emir Unal
FÜFurkan Ünal
Furkan Ünal
OOOnatcan Ozogul
Onatcan Ozogul
MYMümin Murat YAZICI
Mümin Murat YAZICI
EKEREN ONUR KARAVİN
EREN ONUR KARAVİN
AÇAli Çelik
Ali Çelik
Background and Objectives: Hemolysis is the most common preanalytical error in emergency department samples and can compromise diagnostic reliability. Evidence on tourniquet-release timing under standardized pressure is limited. We assessed whether initiating cuff deflation when blood enters the first tube and completing it as that tube fills reduces hemolysis. Materials and Methods: In a single-center, parallel-group, 1:1 randomized trial (ClinicalTrials.gov NCT07617103), 792 adults triaged as Emergency Severity Index (ESI) 3 to 5 underwent venipuncture with stasis applied at 60 mm Hg by sphygmomanometer. Cuff deflation was initiated when blood entered the first tube and completed as that tube filled (n = 396) or after the last tube filled (n = 396). The primary outcome was the proportion of serum separator gel tubes with a hemolysis index of 1+ or greater, assessed by personnel blinded to allocation. The primary complete-case analysis included 790 participants analyzed as randomized. Results: Hemolysis occurred in 68 of 395 patients (17.2%) with early release and 103 of 395 (26.1%) with late release (absolute risk reduction 8.9 percentage points; 95% confidence interval (CI), 3.1–14.5; p = 0.003; number needed to treat (NNT) 11.3). The adjusted odds ratio in the prespecified model was 0.58 (95% CI, 0.41–0.82), and the ordinal distribution also favored early release (p = 0.002). No early-release patient exceeded 60 s of stasis, versus 29.0% with late release. Complication estimates were imprecise (8.1% vs. 5.6%; risk difference +2.5 points; 95% CI, −1.0 to 6.1). Conclusions: In adult emergency department patients presenting with non-critical acuity (ESI 3–5) undergoing direct 21-gauge venipuncture under standardized 60 mm Hg cuff pressure, early cuff release significantly reduced specimen hemolysis (NNT 11.3 for preventing one laboratory-defined hemolyzed sample). These findings cannot be generalized to resuscitated patients (ESI 1–2), intravenous catheter blood draws, winged collection devices, or uncalibrated elastic tourniquets.