We investigate a phenomenological modified inertial mass-flowrate (MIMF) relation for the gravitating-to-luminous mass ratio across heterogeneous galaxy samples. The primary one-parameter calibration uses 136 SPARC galaxies and 2,215 retained radial measurements and gives a₁ = 0.992295 with a galaxy-balanced MAPE of 22.56%. Because the gravitating and luminous mass-flowrate variables share the same characteristic timescale, the construction is algebraically coupled to the target mass ratio and is not interpreted as prediction of an independent observable. A galaxy-level permutation test preserving the mass variables and radial sampling gives a statistically detectable but very small advantage for the observed galaxy-timescale pairing (0.0666 percentage points in GB-MAPE; p = 0.0005), confirming that most of the predictive organization arises from the shared mass structure. Using identical out-of-fold validation, fitting a₁ improves absolute calibration relative to fixing a₁ = 1 (OOF GB-MAPE 22.68% versus 40.15%), while the fixed-unity model retains the higher predictive R². An observational Monte Carlo analysis gives a median a₁ = 0.993516 with a 2.5–97.5 percentile range of 0.992853–0.994129, supporting interpretation of a₁ as an empirical calibration parameter rather than a fundamental exponent. With the SPARC coefficient frozen, MAPEs are 24.86% for Wolf, 15.75% for Courteau, and 8.59% for ATLAS3D; residual offsets are dataset dependent and sensitive to stellar mass-to-light assumptions. On the same retained SPARC radial sample, a standard radial-acceleration-relation benchmark gives a log-acceleration residual RMS of 0.163 dex and a higher predictive R², whereas MIMF gives the lower percentage error on the adopted YM target. These comparisons are not equal-input competitions. Overall, MIMF is best regarded as a compact phenomenological calibration framework whose usefulness and limitations are set by algebraic coupling, sample selection, stellar-mass normalization, and heterogeneous dynamical constructions.
14 June 2026 in Flow Measurement and Instrumentation
This study addresses the Reynolds-number–dependent pressure effect commonly observed in high-pressure gas flow calibration for sonic nozzles and ultrasonic flowmeters (USM). Using long-term calibration datasets, we show that both nozzle discharge coefficients and USM meter errors exhibit pronounced stratification across pressure levels and nozzle throat diameters. To consolidate these behaviors, a modified inertial mass flowrate (MIMF) formulation is proposed, leading to a unified multivariate regression model that simultaneously represents the calibration characteristics of both devices, achieving an overall coefficient of determination of R2 = 0.9998.To assess robustness and generalization, a physically structured 11-fold cross-validation scheme was implemented, with folds defined by nozzle throat diameter and operating pressure. While training and full-data performance remain consistently high across all folds, test performance reveals a clear contrast between pressure-based extrapolation for USM data and geometry-based extrapolation for nozzle data. This asymmetry highlights the intrinsic difficulty of geometric extrapolation and delineates the domain of validity of the proposed model.Because nonlinear optimization exhibits sensitivity to initialization in weakly constrained parameter directions, the full-data optimization was initialized using the mean parameter vector obtained from the cross-validation ensemble. This approach anchors the full-data solution to the parameter manifold independently supported by cross-validation without modifying the objective function. Parameter stability was further evaluated using Mahalanobis distance analysis in the five-dimensional coefficient space, confirming that both cross-validation and full-data solutions reside well within the corresponding chi-square confidence regions.The results support a physically interpretable explanation of the pressure effect as a manifestation of motion-induced inertial perturbations associated with moving mass flowrate, rather than a purely empirical Reynolds-number dependence. The proposed framework provides a unified and statistically validated approach for interpreting pressure effects in high-pressure gas flow measurement.