Andres Osorio Santamaría

Mr. Andres Osorio Santamaría

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2022 in Electric Power Systems Research
Verified
Journal Article
Closed access
CCClara Rojo Ceballos
Clara Rojo Ceballos
JMJuan C Maya
Juan C Maya
Ernesto PerezErnesto Perez
Ernesto Perez
ASAndres Osorio Santamaría
Andres Osorio Santamaría
ACAlexander Alberto Correa-Espinal
Alexander Alberto Correa-Espinal

19 October 2026 in Energies
Verified
Journal Article
Open access
PDF file
Ernesto PerezErnesto Perez
Ernesto Perez
ASAndres Osorio Santamaría
Andres Osorio Santamaría
DADANIEL ARANGUREN-FINO
DANIEL ARANGUREN-FINO
Assessing the lightning performance of real, extensive and highly branched distribution networks is computationally demanding: it requires coupling the electromagnetic field to the line for a large number of Monte Carlo events. This paper proposes a three-stage acceleration method that reduces that burden without compromising accuracy. Events are first pre-screened with an analytical estimate, so only the hazardous ones reach a full coupling simulation. The illumination is then bounded to a distance threshold, with the remaining line represented by a frequency-dependent model that preserves the reflections of the branched topology. Finally, for networks that do not fit in a single case, an optional stage partitions the network into sub-networks solved independently and reconstructed. Every threshold is calibrated against a full-fidelity reference on the same strokes, and the values found are offered as a conservative suggestion for this feeder. Two further elements are addressed: an exposure buffer following the network geometry, and a stopping criterion. The method is evaluated on a real 13.2 kV rural feeder of 116 km spanning about 24 km × 24 km, with an exposure area of 178 km2. The acceleration acts on the indirect strokes, the only ones that need the field-to-line coupling; the direct strokes are simulated and reported separately. The computational cost falls by more than one order of magnitude while the error of the exceedance rate of the indirect strokes stays about 1%, and an independent 200,000-stroke campaign confirms statistical consistency. Convergence should be judged from the number of events above the voltage of interest, not from the apparent stabilization of the estimate.