Linton Evans

Dr. Linton Evans

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2017 in Clinical Cancer Research
Verified
Journal Article
Closed access
PDF file
JEJonathan T. Elliott
Jonathan T. Elliott
KMKayla Marra
Kayla Marra
LELinton Evans
Linton Evans
SDScott Davis
Scott Davis
KSKimberley S. Samkoe
Kimberley S. Samkoe
BPBrian W. Pogue
Brian W. Pogue
Purpose: While extent of tumor resection is an important predictor of outcome in glioma, margin delineation remains challenging due to lack of inherent contrast between tumor and normal parenchyma. Fluorescence-guided surgery is promising for its ability to enhance contrast through exogenous fluorophores; however, the specificity and sensitivity of the underlying contrast mechanism and tumor delivery and uptake vary widely across approved and emerging agents. Experimental Design: Rats with orthotopic F98 wild-type and F98 EGFR-positive (EGFR+) gliomas received in vivo administration of IRDye680RD, 5-aminioleuvulinic acid, and ABY-029—markers of perfusion, protoporphyrin metabolism, and EGFR expression, respectively. Ex vivo imaging demonstrates the contrast mechanism–dependent spatial heterogeneity and enables within-animal comparisons of tumor-to-background ratio (TBR). Results: Generally, ABY-029 outperformed PpIX in F98EGFR orthotopic tumor margins and core (50% and 60% higher TBR, respectively). PpIX outperformed ABY-029 in F98wt margins by 60% but provided equivalent contrast in the bulk tumor. IRDye680RD provided little contrast, having an average TBR of 1.7 ± 0.2. The unique spatial patterns of each agent were combined into a single metric, the multimechanistic fluorescence-contrast index (MFCI). ABY-029 performed best in EGFR+ tumors (91% accuracy), while PpIX performed best in wild-type tumors (87% accuracy). Across all groups, ABY-029 and PpIX performed similarly (80% and 84%, respectively) but MFCI was 91% accurate, supporting multiagent imaging when tumor genotype was unknown. Conclusions: Human use of ABY-029 for glioma resection should enhance excision of EGFR+ tumors and could be incorporated into current PpIX strategies to further enhance treatment in the general glioma case. Clin Cancer Res; 23(9); 2203–12. ©2016 AACR.

1 July 2013 in Neurosurgery Clinics of North America
Verified
Journal Article
Closed access
LELinton Evans
Linton Evans
SLStuart Scott Lollis
Stuart Scott Lollis
PBPerry A. Ball
Perry A. Ball

27 June 2017 in Operative Neurosurgery
Verified
Journal Article
Closed access
SLS Scott Lollis
S Scott Lollis
XFXiaoyao Fan
Xiaoyao Fan
LELinton Evans
Linton Evans
JOJonathan D Olson
Jonathan D Olson
KPKeith D Paulsen
Keith D Paulsen
SJSongbai Ji
Songbai Ji
BACKGROUND: The use of image guidance during spinal surgery has been limited by several anatomic factors such as intervertebral segment motion and ineffective spine immobilization. In its current form, the surgical field is coregistered with a preoperative computed tomography (CT), often obtained in a different spinal confirmation, or with intraoperative cross-sectional imaging. Stereovision offers an alternative method of registration. OBJECTIVE: To demonstrate the feasibility of stereovision-mediated coregistration of a human spinal surgical field using a proof-of-principle study, and to provide preliminary assessments of the technique's accuracy. METHODS: A total of 9 subjects undergoing image-guided pedicle screw placement also underwent stereovision-mediated coregistration with preoperative CT imaging. Stereoscopic images were acquired using a tracked, calibrated stereoscopic camera system mounted on an operating microscope. Images were processed, reconstructed, and segmented in a semi-automated manner. A multistart registration of the reconstructed spinal surface with preoperative CT was performed. Registration accuracy, measured as surface-to-surface distance error, was compared between stereovision registration and a standard registration. RESULTS: The mean surface reconstruction error of the stereovision-acquired surface was 2.20 ± 0.89 mm. Intraoperative coregistration with stereovision was performed with a mean error of 1.48 ± 0.35 mm compared to 2.03 ± 0.28 mm using a standard point-based registration method. The average computational time for registration with stereovision was 95 ± 46 s (range 33-184 s) vs 10to 20 min for standard point-based registration. CONCLUSION: Semi-automated registration of a spinal surgical field using stereovision is possible with accuracy that is at least comparable to current landmark-based techniques.