The aim of this scientific study is to investigate the coupled effects of active battery thermal management on temperature regulation, auxiliary cooling energy demand, and long-term degradation-related exposure under a prescribed tropical heat-soak scenario. A reference 50 Ah equivalent lithium-ion cell is represented by a temperature- and state-of-charge-dependent second-order equivalent-circuit model coupled to a two-node core–surface thermal network. The numerical methods include Coulomb counting, irreversible electrical heat generation, proportional cooling control, time integration of normalized degradation-stress indicators, and ambient-temperature and cooling-setpoint sensitivity analyses. A synthetic 3-day charge–discharge duty cycle and a deterministic 28–42 °C ambient-temperature waveform provide repeatable boundary conditions. Relative to passive operation, the modeled active system lowers peak core temperature while incurring additional cooling electricity demand. The setpoint analysis demonstrates a trade-off between thermal protection, auxiliary energy, and normalized degradation exposure. The framework offers a consistent basis for comparative thermal-management assessment; because the reference parameters and exposure relationships are not experimentally calibrated, it does not establish cell-specific capacity fade, service life, or predictive accuracy.
High ambient temperature and repeated heat-soak exposure can increase the thermal-management burden of electric-vehicle batteries and accelerate temperature-sensitive degradation mechanisms. This study develops a coupled simulation framework combining a second-order resistor–capacitor equivalent-circuit model, state-of-charge dynamics, Bernardi-type heat generation, a two-node core–surface thermal network, proportional active battery thermal management, and Arrhenius-weighted degradation exposure. A repeatable tropical boundary condition of 28–42 \( ^{\circ}C \) is imposed together with a synthetic driving/charging duty cycle. Under the reference parameter set, active thermal management limits the peak simulated core temperature to 35.86 \( ^{\circ}C \) compared with 44.62 \( ^{\circ}C \) for passive operation, a reduction of 8.76 \( ^{\circ}C \). The three-day equivalent-cell BTMS electrical demand is 0.166 kWh and the integrated heat removal is 0.243 kWh. Active cooling reduces the normalized cumulative degradation exposure by approximately 14.0% relative to passive operation. Setpoint sweeps from 28 to 36 \( ^{\circ}C \) quantify the trade-off between cooling energy and degradation exposure. Because cell-specific aging data are not yet available, long-term results are reported as normalized degradation exposure rather than experimentally validated percentage SoH. The framework therefore provides a reproducible basis for subsequent parameter identification, experimental validation, and pack-level lifetime optimization under tropical operating conditions.