This paper introduces an indirect intelligent sliding mode controller (IISMC) for shape memory alloy (SMA) actuators, specifically a flexible beam deflected by a single offset SMA tendon. The controller manipulates applied voltage, which alters SMA tendon temperature to track reference bending angles. A hysteretic recurrent neural network (HRNN) captures the nonlinear, hysteretic relationship between SMA temperature and bending angle. The variable structure control strategy provides robustness to model uncertainties and parameter variations, while effectively compensating for system nonlinearities, achieving superior tracking compared to an optimized PI controller.
1 August 2015 in Journal of Experimental & Clinical Cancer Research
Liver tumors are increasingly treated with radioembolization. Here, we present first evidence of catheter design effect on particle-fluid dynamics and downstream branch targeting during microsphere administrations. A total of 7 experiments were performed in a bench-top model of the hepatic arterial vasculature with recreated hemodynamics. Fluorescent microspheres and clinically used holmium microspheres were administered with a standard microcatheter (SMC) and an anti-reflux catheter (ARC) positioned at the same level along the longitudinal vessel axis. Catheter-related particle flow dynamics were analyzed by reviewing video recordings of UV-light illuminated fluorescent microsphere administrations. Downstream branch distribution was analyzed by quantification of collected microspheres in separate filters for two first-order branches. Mean deviation from a perfectly homogenous distribution (DHD) was used to compare the distribution homogeneity between catheter types. The SMC administrations demonstrated a random off-centered catheter position (in 71 % of experiments), and a laminar particle flow pattern with an inhomogeneous downstream branch distribution, dependent on catheter position and injection force. The ARC administrations demonstrated a fixed centro-luminal catheter position, and a turbulent particle flow pattern with a more consistent and homogenous downstream branch distribution. Quantitative analyses confirmed a significantly more homogeneous distribution with the ARC; the mean DHD was 40.85 % (IQR 22.76 %) for the SMC and 15.54 % (IQR 6.46 %) for the ARC (p = 0.047). Catheter type has a significant impact on microsphere administrations in an in-vitro hepatic arterial model. A within-patient randomized controlled trial has been initiated to investigate clinical catheter-related effects during radioembolization treatment.
18 February 2009 in Annals of Biomedical Engineering
During the past , tremendous advancements have been made in the fields of minimally invasive surgery (MIS) and minimally invasive, robotically assisted (MIRA) cardiac surgery. Benefits from MIS include reduced pain and trauma, reduced risks of post-operative complications, shorter recovery times, and more aesthetically pleasing results. MIRA approaches have extended the capabilities of MIS by introducing three-dimensional vision, eliminating hand tremors, and enabling the precise articulation of smaller instruments. These advancements come with their own drawbacks, however. Robotic systems used in MIRA cardiac procedures are large, costly, and do not offer the miniaturized articulation necessary to facilitate tremendous advancements in MIS. This paper demonstrates that miniature actuation can overcome some of the limitations of current robotic systems by providing accurate, repeatable control of a small end effector. A model of a two link surgical manipulator is developed, using antagonistic shape memory alloy wires as actuators, to simulate motions of a surgical end-effector. Artificial neural networks are used in conjunction with real-time visual feedback to “learn” the inverse system dynamics and control the manipulator endpoint trajectory. Experimental results are presented for indirect, on-line learning and control. Manipulator tip trajectories are shown to be accurate and repeatable to within . These results confirm that SMAs can be effective actuators for miniature surgical robotic systems, and that intelligent control can be used to accurately control the trajectory of these systems.