Intrapartum Fetal Heart Rate (FHR) monitoring is crucial for the early detection of abnormal FHR, facilitating timely obstetric interventions and thus the potential reduction of adverse perinatal outcomes. We explored midwifery practices of intrapartum FHR monitoring pre and post implementation of a novel continuous automatic Doppler device (the Moyo). A pre/post observational study among low-risk pregnancies at a tertiary hospital was conducted from March to December 2016. In the pre-implementation period, intermittent monitoring was conducted with a Pinard stethoscope (March to June 2016, n = 1640 women). In the post-implementation period, Moyo was used for continuous FHR monitoring (July-December 2016, n = 2442 women). The primary outcome was detection of abnormal FHR defined as absent, FHR160bpm. The secondary outcomes were rates of assessment/documentation of FHR, obstetric time intervals and intrauterine resuscitations. Chi-square test, Fishers exact test, t-test and Mann-Whitney U test were used in bivariate analysis whereas binary and multinomial logistic regression were used for multivariate. Moyo use was associated with greater detection of abnormal FHR (8.0%) compared with Pinard (1.6%) (p<0.001). There were higher rates of non-assessment/documentation of FHR pre- (45.7%) compared to post-implementation (2.2%) (p<0.001). At pre-implementation, 8% of deliveries had FHR documented as often as ≤ 60 minutes, compared to 51% post-implementation (p<0.001). Implementation of continuous FHR monitoring was associated with a shorter time interval from the last FHR assessment to delivery i.e. median (IQR) of 60 (30,100) to 45 (21,85) minutes (p<0.001); and shorter time interval between each FHR assessment i.e. from 150 (86,299) minutes to 60 (41,86) minutes (p<0.001). Caesarean section rates increased from 2.6 to 5.4%, and vacuum deliveries from 2.2 to 5.8% (both p<0.001). Perinatal outcomes i.e. fresh stillbirths and early neonatal deaths were similar between time periods. The study was limited by both lack of randomization and involvement of low-risk pregnant women with fewer adverse perinatal outcomes than would be expected in a high-risk population. Implementation of the Moyo device, which continuously measures FHR, was associated with improved quality in FHR monitoring practices and the detection of abnormal FHR. These improvements led to more frequent and timely obstetric responses. Follow-up studies in a high-risk population focused on a more targeted description of the FHR abnormalities and the impact of intrauterine resuscitation is a critical next step in determining the effect on reducing perinatal mortality.
The global prevalence of low birth weight (LBW) is 16%, representing more than 20 million infants worldwide, of which 96% are born in low-income countries. This study aimed to determine the prevalence, predictors and perinatal outcomes of LBW newborns. We conducted a retrospective analysis of data obtained from the hospital's obstetric and neonatal database. Descriptive statistics and multivariate logistic regression were performed with 95% confidence intervals (CI). The prevalence of LBW was 21% (n = 8,011) and two-thirds of these were delivered at term. Seven percent of newborns were stillbirths and 2% died within 24hrs after birth. Logistic regression revealed that primigravida and grand multiparity were associated with LBW (OR: 1.25, 95%CI: 1.15-1.37; and OR: 1.21, 95%CI: 1.01-1.25, respectively). Having <4 antenatal care (ANC) visits was associated with increased odds of LBW (OR: 1.74, 95%CI: 1.59-1.87). Regression models revealed an independent association between LBW and increased odds of stillbirths (OR = 7.20, 95%CI 6.71-7.90), low Apgar score (OR = 3.42, 95%CI: 3.12-3.76) and early neonatal deaths (OR = 1.82, 95%CI: 1.51-2.19). The prevalence of LBW was high and was associated with extreme maternal age groups, grand multiparity, low maternal education, low number of ANC visits and obstetrics risks factors and complications. Both LBW and prematurity were independently associated with poor perinatal outcome. Future interventions should focus on improving the quality of ANC and integrating peripartum emergency obstetric and neonatal care.
Background: Intrapartum foetal heart rate (FHR) monitoring is crucial for identification of hypoxic foetuses and subsequent interventions. We compared continuous monitoring using a novel nine-crystal FHR monitor (Moyo) versus intermittent single crystal Doppler (Doppler) for the detection of abnormal FHR. Methods: An unmasked randomised controlled study was conducted in a tertiary hospital in Tanzania (ClinicalTrials.gov Identifier: NCT02790554). A total of 2973 low-risk singleton pregnant women in the first stage of labour admitted with normal FHR were randomised to either Moyo (n = 1479) or Doppler (1494) arms. The primary outcome was the proportion of abnormal FHR detection. Secondary outcomes were time intervals in labour, delivery mode, Apgar scores, and perinatal outcomes. Results: Moyo detected abnormal FHR more often (13.3%) compared to Doppler (9.8%) (p = 0.002). Time intervals from admission to detection of abnormal FHR were 15% shorter in Moyo (p = 0.12) and from the detection of abnormal FHR to delivery was 36% longer in Moyo (p = 0.007) compared to the Doppler arm. Time from last FHR to delivery was 12% shorter with Moyo (p = 0.006) compared to Doppler. Caesarean section rates were higher with the Moyo device compared to Doppler (p = 0.001). Low Apgar scores (<7) at the 1st and 5th min were comparable between groups (p = 0.555 and p = 0.800). Perinatal outcomes (fresh stillbirths and 24-h neonatal deaths) were comparable at delivery (p = 0.497) and 24-h post-delivery (p = 0.345). Conclusions: Abnormal FHR detection rates were higher with Moyo compared to Doppler. Moyo detected abnormal FHR earlier than Doppler, but time from detection to delivery was longer. Studies powered to detect differences in perinatal outcomes with timely responses are recommended.
Background: The burden of stillbirth, neonatal and maternal deaths are unacceptably high in low- and middle-income countries, especially around the time of birth. There are scarce resources and/or support implementation of evidence-based training programs. SaferBirths Bundle of Care is a well-proven package of innovative tools coupled with data-driven on-the-job training aimed at reducing perinatal and maternal deaths. The aim of this project is to determine the effect of scaling up the bundle on improving quality of intrapartum care and perinatal survival. Methods: The project will follow a stepped-wedge cluster implementation design with well-established infrastructures for data collection, management, and analysis in 30 public health facilities in regions in Tanzania. Healthcare workers from selected health facilities will be trained in basic neonatal resuscitation, essential newborn care and essential maternal care. Foetal heart rate monitors (Moyo), neonatal heart rate monitors (NeoBeat) and skills trainers (NeoNatalie Live) will be introduced in the health facilities to facilitate timely identification of foetal distress during labour and improve neonatal resuscitation, respectively. Heart rate signal-data will be automatically collected by Moyo and NeoBeat, and newborn resuscitation training by NeoNatalie Live. Given an average of 4000 baby-mother pairs per year per health facility giving an estimate of 240,000 baby-mother pairs for a 2-years duration, 25% reduction in perinatal mortality at a two-sided significance level of 5%, intracluster correlation coefficient (ICC) to be 0.0013, the study power stands at 0.99. Discussion: Previous reports from small-scale Safer Births Bundle implementation studies show satisfactory uptake of interventions with significant improvements in quality of care and lives saved. Better equipped and trained birth attendants are more confident and skilled in providing care. Additionally, local data-driven feedback has shown to drive continuous quality of care improvement initiatives, which is essential to increase perinatal and maternal survival. Strengths of this research project include integration of innovative tools with existing national guidelines, local data-driven decision-making and training. Limitations include the stepwise cluster implementation design that may lead to contamination of the intervention, and/or inability to address the shortage of healthcare workers and medical supplies beyond the project scope. Trial registration: Name of Trial Registry: ISRCTN Registry. Trial registration number: ISRCTN30541755. Date of Registration: 12/10/2020. Type of registration: Prospectively Registered.
The Fataki campaign aired in Tanzania via radio from 2008 to 2011 to address cross-generational sex, a major driver of HIV in the region. The campaign sought to incite social disapproval of men who engage in such relationships, generate dialogue around the issue, and encourage community interventions in these relationships through social learning. Using qualitative methods, we explored campaign reactions, use of the term Fataki to describe men in relationships with much younger women, and the nature of discussions spurred by the campaign. We conducted focus group discussions and individual interviews in Iringa and Pwani regions with young women, older men, and community leaders. Results showed that the Fataki term was widely used and had negative connotations reflecting social disapproval of men who participate in such relationships. Dialogue spurred by the campaign, primarily directed toward young women, focused on reasons for avoiding these relationships. We conclude with suggestions for relevant future interventions.
Safer Births Bundle of Care (SBBC) consists of innovative clinical and training tools for improved labour care and newborn resuscitation, integrated with new strategies for continuous quality improvement. After implementation, we hypothesised a reduction in 24-h newborn deaths, fresh stillbirths, and maternal deaths by 50%, 20%, and 10%, respectively. This is a 3-year stepped-wedged cluster randomised implementation study, including 30 facilities within five regions in Tanzania. Data collectors at each facility enter labour and newborn care indicators, patient characteristics and outcomes. This halfway evaluation reports data from March 2021 through July 2022. In total, 138,357 deliveries were recorded; 67,690 pre- and 70,667 post-implementations of SBBC. There were steady trends of increased 24-h newborn and maternal survival in four regions after SBBC initiation. In the first region, with 13 months of implementation (n = 15,658 deliveries), an estimated additional 100 newborns and 20 women were saved. Reported fresh stillbirths seemed to fluctuate across time, and increased in three regions after the start of SBBC. Uptake of the bundle varied between regions. This SBBC halfway evaluation indicates steady reductions in 24-h newborn and maternal mortality, in line with our hypotheses, in four of five regions. Enhanced focus on uptake of the bundle and the quality improvement component is necessary to fully reach the SBBC impact potential as we move forward.