George Papadakis

Dr. George Papadakis


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GPGeorge Papadakis
George Papadakis
APA. K. Pantazis
A. K. Pantazis
NFN. Fikas
N. Fikas
SCS. Chatziioannidou
S. Chatziioannidou
VTV. Tsiakalou
V. Tsiakalou
Electra GizeliElectra Gizeli
Electra Gizeli
Loop-mediated isothermal amplification is known for its high sensitivity, specificity and tolerance to inhibiting-substances. In this work, we developed a device for performing real-time colorimetric LAMP combining the accuracy of lab-based quantitative analysis with the simplicity of point-of-care testing. The device innovation lies on the use of a plastic tube anchored vertically on a hot surface while the side walls are exposed to a mini camera able to take snapshots of the colour change in real time during LAMP amplification. Competitive features are the rapid analysis (< 30 min), quantification over 9 log-units, crude sample-compatibility (saliva, tissue, swabs), low detection limit (< 5 copies/reaction), smartphone-operation, fast prototyping (3D-printing) and ability to select the dye of interest (Phenol red, HNB). The device’s clinical utility is demonstrated in cancer mutations-analysis during the detection of 0.01% of BRAF-V600E-to-wild-type molecules from tissue samples and COVID-19 testing with 97% (Ct < 36.8) and 98% (Ct < 30) sensitivity when using extracted RNA and nasopharyngeal-swabs, respectively. The device high technology-readiness-level makes it a suitable platform for performing any colorimetric LAMP assay; moreover, its simple and inexpensive fabrication holds promise for fast deployment and application in global diagnostics.

19 October 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
SSStefanos Soultatos
Stefanos Soultatos
MMMaria Megariti
Maria Megariti
NKNikolaos Emmanouil Krasagakis
Nikolaos Emmanouil Krasagakis
GPGeorge Papadakis
George Papadakis
SCStella Chatziioannidou
Stella Chatziioannidou
Emmanouil MarkakisEmmanouil Markakis
Emmanouil Markakis
In the present study, a novel method was developed and validated for the early, rapid and on-site detection of Botrytis cinerea in crude tomato samples using a newly designed loop-mediated isothermal amplification (LAMP) assay and the portable device PEBBLE. LAMP primers (targeting the IGS region of rDNA gene) were designed, and the sensitivity, specificity and accuracy of the developed method were determined (97.96%, 100% and 98.70%, respectively). The LAMP assay, combined with the portable device, enabled real-time quantitative colorimetric (qcLAMP) detection of B. cinerea in less than 30 min. The limit of detection (LoD) of the qcLAMP assay was 1 pg genomic DNA (≈20 genome copies) per reaction, whereas conventional PCR (utilized as the gold standard method) detected no less than 100 pg of genomic DNA per reaction. In terms of B. cinerea infective propagules, qcLAMP could detect as few as 10² spores in both pure and crude DNA samples extracted from artificially inoculated tomato leaves, whereas PCR detected no fewer than 10⁴ spores in pure DNA samples, failing to achieve detection in crude extracts. In in-vivo bioassays, qcLAMP successfully detected B. cinerea immediately following spore deposition on leaf tissues (0 hours post inoculation) in both pure and crude DNA extracts. In contrast, conventional PCR was successful only in pure DNA samples from leaves collected 2 days post inoculation (dpi) and in crude extracts at 3 dpi, when symptoms were already evident. Evaluations in field samples demonstrated that qcLAMP detected B. cinerea in 100% of crude extracts from symptomatic tissues and in 45% of asymptomatic (latently infected) samples. Conversely, conventional PCR failed to detect the pathogen in crude extracts, regardless of the disease status (symptomatic or asymptomatic). The developed method can serve as a rapid, reliable, and user-friendly tool for the early detection of B. cinerea in the field, enabling prompt assessment of inoculum pressure, thereby facilitating timely management interventions.