We aimed to investigate the value of magnetic resonance imaging (MRI)-based parameters in differentiating between progressive massive fibrosis (PMF) and lung cancer. This retrospective study included 60 male patients (mean age, 67.0±9.0 years) with a history of more than 10 years working in underground coal mines who underwent 1.5 T MRI of thorax due to a lung nodule/mass suspicious for lung cancer on computed tomography. Thirty patients had PMF, and the remaining ones had lung cancer diagnosed histopathologically. The sequences were as follows: coronal single-shot turbo spin echo (SSH-TSE), axial T1- and T2-weighted spin-echo (SE), balanced turbo field echo, T1-weighted high-resolution isotropic volume excitation, free-breathing and respiratory triggered diffusion-weighted imaging (DWI). The patients’ demographics, lesion sizes, and MRI-derived parameters were compared between the patients with PMF and lung cancer. Apparent diffusion coefficient (ADC) values of DWI and respiratory triggered DWI, signal intensities on T1-weighted SE, T2-weighted SE, and SSH-TSE imaging were found to be significantly different between the groups (p < 0.001, for all comparisons). Median ADC values of free-breathing DWI in patients with PMF and cancer were 1.25 (0.93–2.60) and 0.76 (0.53–1.00) (× 10−3 mm2/s), respectively. Most PMF lesions were predominantly iso- or hypointense on T1-weighted SE, T2-weighted SE, and SSH-TSE, while most malignant ones predominantly showed high signal intensity on these sequences. MRI study including SE imaging, specially T1-weighted SE imaging and ADC values of DWI can help to distinguish PMF from lung cancer.
We aimed to demonstrate the feasibility of ultrasound (US)-guided retrograde tibial access through chronically occluded tibial arteries as a bailout endovascular recanalization procedure in patients with critical limb ischemia (CLI). Fifty-one CLI patients with failed conventional antegrade tibiopedal recanalization required retrograde tibiopedal access in the same session. In all of these patients, the target tibial artery was chronically occluded in at least the distal half of the cruris. Access attempts were made under real-time US by a single operator experienced in image-guided vascular access procedures. Fluoroscopy was used only as an adjunct during advancement of a 0.018 inch guidewire. If access to the artery was successful by the retrograde route, the occluded artery was usually predilated with a 2 mm balloon, and the standard endovascular treatment was mostly performed through the antegrade route. Patients had athereosclerosis (n = 35) or Buerger’s disease (n = 32) and presented with Rutherford category IV and category V. Successful placement of a guidewire in the occluded artery lumen was achieved in 81% of all patients, whereas, treatment success, i.e. angiographic demonstration of in-line flow at the end of procedure, was achieved in 49%. No significant procedure-related complications were observed. Of 33 limbs with initially successful endovascular treatment, 6 required minor and 1 required major amputation during follow-up. US-guided retrograde access through completely occluded tibial arteries is difficult but feasible. Half of the tibial arteries that could not be recanalized otherwise were converted to successful recanalization by this method.
17 March 2022 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: Most distal MCA aneurysms are located within the insular segment, which lies between the limen insulae and circular sulcus. However, experience is limited in the microsurgical and endovascular management of insular segment MCA aneurysms. In this multicenter retrospective case series, we aimed to investigate the safety, efficacy, and durability of stent-assisted coiling for treatment of insular segment MCA aneurysms. MATERIALS AND METHODS: A retrospective review was performed to identify patients with insular MCA aneurysms that were treated with stent-assisted coiling. The technical success of the procedures and the initial and follow-up clinical and angiographic outcomes were assessed. Periprocedural and delayed complications were reviewed. RESULTS: Twenty-seven aneurysms in 27 patients with a mean age of 53.3 (SD,11.3) years were included. The mean size of the aneurysms was 6.3 (SD 2.6) mm. Endovascular procedures were successfully performed in all patients. Immediate postprocedural angiography revealed complete aneurysm occlusions in 81.5%. Periprocedural complications developed in 7.4% without causing permanent morbidity. A delayed thromboembolic complication resulted in a minor permanent morbidity in 1 patient (3.7%). There was no mortality. The mean duration of angiographic follow-up was 19.5 (SD, 9.8) months. The last follow-up examinations showed complete occlusion in 92.6%. During the follow-up period, none of the treated aneurysms showed recanalization. CONCLUSIONS: The results of this study demonstrate that stent-assisted coiling with a low-profile self-expandable stent is a feasible and relatively safe technique for endovascular treatment of insular segment complex MCA aneurysms. Additionally, it provides an effective and durable treatment for insular MCA aneurysms.
Background/Objectives: The objective of this study was to assess the connection between the systemic inflammation response index (SIRI) values and failure patterns of patients with IDH wild-type glioblastoma (GB) who underwent radiotherapy (RT) with FLAIR-based gross tumor volume (GTV) delineation. Methods: Seventy-one patients who received RT at a dose of 60 Gy to the GTV and 50 Gy to the clinical target volume (CTV) and had documented recurrence were retrospectively analyzed. Each patient’s maximum distance of recurrence (MDR) from the GTV was documented in whichever plane it extended the farthest. The failure patterns were described as intra-GTV, in-CTV/out-GTV, distant, and intra-GTV and distant. For analytical purposes, the failure pattern was categorized into two groups, namely Group 1, intra-GTV or in-CTV/out-GTV, and Group 2, distant or intra-GTV and distant. The SIRI was calculated before surgery and corticosteroid administration. A receiver operating characteristic (ROC) curve analysis was used to determine the optimal SIRI cut-off that distinguishes between the different failure patterns. Results: Failure occurred as follows: intra-GTV in 40 (56.3%), in-CTV/out-GTV in 4 (5.6%), distant in 18 (25.4%), and intra-GTV + distant in 9 (12.7%) patients. The mean MDR was 13.5 mm, and recurrent lesions extended beyond 15 mm in only seven patients. Patients with an SIRI score ≥ 3 demonstrated a significantly higher incidence of Group 1 failure patterns than their counterparts with an SIRI score < 3 (74.3% vs. 50.0%; p = 0.035). Conclusions: The present results show that using the SIRI with a cut-off value of ≥3 significantly predicts failure patterns. Additionally, the margin for the GTV can be safely reduced to 15 mm when using FLAIR-based target delineation in patients with GB.
25 February 2020 in Diagnostic and Interventional Radiology
PURPOSE In this study, we aimed to analyze the repeatability of quantitative multiparametric rectal magnetic resonance imaging (MRI) parameters with different measurement techniques. METHODS All examinations were performed with 3 T MRI system. In addition to routine sequences for rectal cancer imaging protocol, small field-of-view diffusion-weighted imaging and perfusion sequences were acquired in each patient. Apparent diffusion coefficient (ADC) was used for diffusion analysis and k(trans) was used for perfusion analysis. Three different methods were used in measurement of these parameters; measurements were performed twice by one radiologist for intraobserver and separately by three radiologists for interobserver variability analysis. ADC was measured by the lowest value, the value at maximum wall thickness, and freehand techniques. K-trans was measured at the slice with maximum wall thickness, by freehand drawn region of interest (ROI), and at the dark red spot with maximum value. RESULTS A total of 30 patients with biopsy-proven rectal adenocarcinoma were included in the study. The mean values of the parameters measured by the first radiologist on the first and second measurements were as follows: mean lowest ADC, 721.31 +/- 147.18 mm(2)/s and 718.96 +/- 135.71 mm(2)/s; mean ADC value on the slice with maximum wall thickness, 829.90 +/- 144.24 mm(2)/s and 829.48 +/- 149.23 mm(2)/s; mean ADC value measured by freehand ROI on the slice with maximum wall thickness, 846.56 +/- 136.31 mm(2)/s and 848.23 +/- 144.15 mm(2)/s; mean k(trans) value on the slice with maximum wall thickness, 0.219 +/- 0.080 and 0.214 +/- 0.074; mean k(trans) by freehand ROI technique (including as much tumoral tissue as possible), 0.208 +/- 0.074 and 0.207 +/- 0.069; mean k(trans) measured from the dark red foci, 0.308 +/- 0.109 and 0.311 +/- 0.105. Intraobserver agreement was very good among diffusion and perfusion parameters obtained with all three measurement techniques. Interobserver agreement was very good, except for one of the measurement techniques. As far as interobserver variability is considered, only ADC value measured on the slice with maximum wall thickness differed significantly. CONCLUSION Multiparametric MRI of rectum, using ADC as the diffusion and k(trans) as the perfusion parameter is a repeatable technique. This technique may potentially be used in prediction and evaluation of neoadjuvant treatment response. New studies with larger patient groups are needed to validate the role of multiparametric MRI.