Shear wave elastography (SWE) is widely used in clinical work. But there is no standard protocol and operation specification for SWE acquisition methods, which impacts the diagnosis and clinical staging. This study aimed to investigate the influence factors of diameter, depth, and stiffness on SWE using different probes at superficial depths and discuss SWE differences with two machines at superficial depths. We performed SWE on two elastic phantoms that each phantom contained six subjects with two stiffness (41.06 ± 4.62 kpa and 57.30 ± 4.31 kpa), three diameters (10, 15, and 18 mm), and two depths (15 and 25 mm). A total of 240 measurements were obtained by using two ultrasound machines (SuperSonic Imagine Aixplorer and Mindray Resona 7) and 4 probes (SL15-4 and SL10-2, L11-3, and L14-5). The measurements were compared among 4 probes, 3 diameters, and 2 depths. There was no significant difference in SWE measurements among the probes from the same machine. The SWE measurements were affected by diameter, and the degree of influence was related to the stiffness. The SWE measurements were unaffected at a 15–25 mm depth range.
Purpose: The aim of this study was to develop and validate a dynamic nomogram by combining conventional ultrasound (US) and contrast-enhanced US (CEUS) to preoperatively evaluate the probability of central lymph node metastases (CLNMs) for patients with papillary thyroid carcinoma (PTC).Methods: A total of 216 patients with PTC confirmed pathologically were included in this retrospective and prospective study, and they were divided into the training and validation cohorts, respectively. Each cohort was divided into the CLNM (+) and CLNM (−) groups. The least absolute shrinkage and selection operator (LASSO) regression method was applied to select the most useful predictive features for CLNM in the training cohort, and these features were incorporated into a multivariate logistic regression analysis to develop the nomogram. The nomogram’s discrimination, calibration, and clinical usefulness were assessed in the training and validation cohorts.Results: In the training and validation cohorts, the dynamic nomogram (https://clnmpredictionmodel.shinyapps.io/PTCCLNM/) had an area under the receiver operator characteristic curve (AUC) of 0.844 (95% CI, 0.755–0.905) and 0.827 (95% CI, 0.747–0.906), respectively. The Hosmer–Lemeshow test and calibration curve showed that the nomogram had good calibration (p = 0.385, p = 0.285). Decision curve analysis (DCA) showed that the nomogram has more predictive value of CLNM than US or CEUS features alone in a wide range of high-risk threshold. A Nomo-score of 0.428 as the cutoff value had a good performance to stratify high-risk and low-risk groups.Conclusion: A dynamic nomogram combining US and CEUS features can be applied to risk stratification of CLNM in patients with PTC in clinical practice.
Background Metabolic dysfunction-associated fatty liver disease (MAFLD) is the most common chronic liver disease in the world and carries an increased risk of liver-related events, but no approved medicine. Electroacupuncture has been used to treat non-alcoholic fatty liver disease, but its effect was uncertain because of the poor quality of prior studies. We designed this trial to evaluate the efficacy and safety of electroacupuncture for MAFLD. Methods/design This is a multicentre, randomised, sham acupuncture-controlled, patient-blinded clinical trial. Participants will take part in a total of 20 weeks of study, containing three phases: a 4‐week run-in period, 12‐week treatment (36 sessions of acupuncture) and 4‐week follow‐up. A total of 144 eligible patients diagnosed with MAFLD will be randomly allocated to the electroacupuncture or sham acupuncture groups. The primary outcome is the percentage of relative liver fat reduction on the MRI proton density fat fraction from baseline to 12 weeks. Secondary outcomes include magnetic resonance elastography, liver and metabolic biomarkers, anthropometry parameters, blinding assessment, credibility and expectancy, and adverse events. All patients who receive randomisation will be included in the intent-to-treat analysis. Discussion The finding of this trial will provide evidence of the efficacy and safety of electroacupuncture for the treatment of MAFLD. The results of this study will be published in peer-reviewed journals. Trial registration number www.chictr.org.cn, ChiCTR2200060353. It was registered on 29 May 2022.
4 September 2024 in Journal of Ultrasound in Medicine