Background: Cognitive impairment is one of the most common, burdensome, and costly disorders in the elderly worldwide. The magnitude of the association between anemia and overall cognitive impairment (OCI) has not been established. Objective: We aimed to update and expand previous evidence of the association between anemia and the risk of OCI. Methods: We conducted an updated systematic review and meta-analysis. We searched electronic databases, including EMBASE, PubMed, and Web of Science for published observational studies and clinical trials between 1 January 1990 and 1 June 2020. We excluded articles that were in the form of a review, letter to editors, short reports, and studies with less than 50 participants. The Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines were followed. We estimated summary risk ratios (RRs) with random effects. Results: A total of 20 studies, involving 6558 OCI patients were included. Anemia was significantly associated with an increased risk of OCI (adjusted RR (aRR) 1.39 (95% CI, 1.25–1.55; p < 0.001)). In subgroup analysis, anemia was also associated with an increased risk of all-cause dementia (adjusted RR (aRR), 1.39 (95% CI, 1.23–1.56; p < 0.001)), Alzheimer’s disease [aRR, 1.59 (95% CI, 1.18–2.13; p = 0.002)], and mild cognitive impairment (aRR, 1.36 (95% CI, 1.04–1.78; p = 0.02)). Conclusion: This updated meta-analysis shows that patients with anemia appear to have a nearly 1.39-fold risk of developing OCI than those without anemia. The magnitude of this risk underscores the importance of improving anemia patients’ health outcomes, particularly in elderly patients.
1 April 2021 in Journal of Multidisciplinary Healthcare
Background: Incidence of skin cancer is one of the global burdens of malignancies that increase each year, with melanoma being the deadliest one. Imaging-based automated skin cancer detection still remains challenging owing to variability in the skin lesions and limited standard dataset availability. Recent research indicates the potential of deep convolutional neural networks (CNN) in predicting outcomes from simple as well as highly complicated images. However, its implementation requires high-class computational facility, that is not feasible in low resource and remote areas of health care. There is potential in combining image and patient’s metadata, but the study is still lacking. Objective: We want to develop malignant melanoma detection based on dermoscopic images and patient’s metadata using an artificial intelligence (AI) model that will work on low-resource devices. Methods: We used an open-access dermatology repository of International Skin Imaging Collaboration (ISIC) Archive dataset consist of 23,801 biopsy-proven dermoscopic images. We tested performance for binary classification malignant melanomas vs nonmalignant melanomas. From 1200 sample images, we split the data for training (72%), validation (18%), and testing (10%). We compared CNN with image data only (CNN model) vs CNN for image data combined with an artificial neural network (ANN) for patient’s metadata (CNN+ANN model). Results: The balanced accuracy for CNN+ANN model was higher (92.34%) than the CNN model (73.69%). Combination of the patient’s metadata using ANN prevents the overfitting that occurs in the CNN model using dermoscopic images only. This small size (24 MB) of this model made it possible to run on a medium class computer without the need of cloud computing, suitable for deployment on devices with limited resources. Conclusion: The CNN+ANN model can increase the accuracy of classification in malignant melanoma detection even with limited data and is promising for development as a screening device in remote and low resources health care.
Object: Controversy exists over the choice of surgical candidates and prognosis of Hirayama disease. The purpose of this study was to examine the outcomes of patients with cervical flexion myelopathy who received surgical treatment. Methods: A retrospective study was conducted. From May 2002 through December 2006, 6 young patients with cervical flexion myelopathy were seen in the Department of Neurosurgery at Chang Gung Memorial Hospital. The neurological and radiological findings in all 6 patients met the criteria for Hirayama disease. All patients had evidence of a tight dural canal or forward migration of the posterior wall of the dural canal in dynamic MR imaging studies. Five patients were treated with surgical decompressive procedures (4 anterior and 1 posterior) and 1 patient received conservative treatment. Duration of follow-up ranged from 13 months to 4 years. Results: Motor function improved in 3 of 5 surgically treated patients and sensory function improved in 2. Neurological symptoms were unchanged in the conservatively treated patient. During follow-up MR imaging in the surgical group, anterior effacement during neck flexion was noted in 1 patient treated with a posterior approach. Conclusions: Hirayama disease is so rare that it is easily misdiagnosed. Diagnosis is achieved via clinical presentation, neurophysiological examination, and neuroradiological imaging studies (dynamic MR imaging). The anterior decompressive approach may be better for patients showing anterior effacement and severe cervical kyphosis during neck flexion in MR imaging.
In the current open society and with the growth of human rights, people are more and more concerned about the privacy of their information and other important data. This study makes use of electrocardiography (ECG) data in order to protect individual information. An ECG signal can not only be used to analyze disease, but also to provide crucial biometric information for identification and authentication. In this study, we propose a new idea of integrating electrocardiogram watermarking and compression approach, which has never been researched before. ECG watermarking can ensure the confidentiality and reliability of a user’s data while reducing the amount of data. In the evaluation, we apply the embedding capacity, bit error rate (BER), signal-to-noise ratio (SNR), compression ratio (CR), and compressed-signal to noise ratio (CNR) methods to assess the proposed algorithm. After comprehensive evaluation the final results show that our algorithm is robust and feasible.