Aseel Mahmood

Dr. Aseel Mahmood


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2015 in Optics Letters
Verified
Journal Article
Closed access
PDF file
AMAseel Mahmood
Aseel Mahmood
VKVishnu Kavungal
Vishnu Kavungal
SASudad S. Ahmed
Sudad S. Ahmed
GFGerald Farrell
Gerald Farrell
Yuliya SemenovaYuliya Semenova
Yuliya Semenova
In this work, a magnetic-field sensor was designed to take advantage of the tunability of the resonance wavelengths of a cylindrical whispering-gallery-mode microresonator. The microresonator is based on a 1.3 cm length of photonic crystal fiber infiltrated with a magnetic fluid containing nanoparticles with diameters of either 5 or 10 nm. The Q-factor achieved for the microresonators was 4.24×103 or higher. When a magnetic field is applied, the whispering-gallery-mode resonances shift toward longer wavelengths. The experimentally demonstrated sensitivity of the proposed sensor was as high as 110 pm/mT in the magnetic field range from 0 to 38.7 mT.

16 May 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
AMAseel Mahmood
Aseel Mahmood
VKVishnu Kavungal
Vishnu Kavungal
SASudad S. Ahmed
Sudad S. Ahmed
PKPeter Kopcansky
Peter Kopcansky
VZVlasta Zavisova
Vlasta Zavisova
Yuliya SemenovaYuliya Semenova
Yuliya Semenova
An all-fiber magnetic field sensor based on whispering-gallery modes (WGM) in a fiber micro-resonator infiltrated with ferronematic liquid crystal is proposed and experimentally demonstrated. The cylindrical microresonator is formed by a 1 cm-long section of a photonic crystal fiber infiltrated with ferronematic materials. Both ferronematics suspensions are prepared based on the nematic liquid crystal 1-(trans-4-Hexylcyclohexyl)-4-isothiocyanatobenzene (6CHBT) doped with rod-like magnetic particles in the first case and with spherical magnetic particles in the second case. WGMs are excited in the fiber microresonator by evanescent light coupling using a tapered fiber with a micron-size diameter. The Q-factor of the microresonator determined from the experimentaly measured transmission spectrum of the tapered fiber was 1.975 × 103. Under the influence of an applied magnetic field the WGM resonances experience spectral shift towards shorter wavelengths. The experimentally demonstrated sensitivity of the proposed sensor was −39.6 pm/mT and −37.3 pm/mT for samples infiltrated with rod like and spherical like ferromagnetic suspensions respectively for a magnetic field range (0-47) mT. Reducing the diameter of the cylindrical micro-resonator by tapering leads to enhancement of the magnetic field sensitivity up to −61.86 pm/mT and −49.88 pm/mT for samples infiltrated with rod like and spherical like ferromagnetic suspensions respectively for the magnetic field range (0-44.7) mT.

24 May 2018 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
AMAseel Mahmood
Aseel Mahmood
RIRawa Kh Ibrahim
Rawa Kh Ibrahim
AMAml I Mahmood
Aml I Mahmood
ZIZainab Kh Ibrahim
Zainab Kh Ibrahim

1 June 2021 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
MAMohamed J. Ali
Mohamed J. Ali
AAAlaa H. Ali
Alaa H. Ali
AMAseel Mahmood
Aseel Mahmood
MHMohammed A. Hussien
Mohammed A. Hussien
A fiber Brag grating-based temperature sensor FBG together with high accuracy, resolution and compact size interrogation system using a short period grating was presented in this work. The designed sensor measures the temperature from 35 °C temperature to 41 °C which is represented the ranges of human body temperature for use in medical applications. In this paper, we present some results obtained from experiments within a measurement range from (35°C to 40°C) which is from hypothermia to hyperthermia) that the sensor has high sensitivity and high resolution of (85.9%) for FBG sensor. After the results we obtained and the features that the sensor enjoys, such as small size, immunity from electrical influence, and the ability to work in environments Magnetic Resonance Imaging (MRI) environments. The sensor can be used in hospitals and clinics for improvement and monitoring of patients. The importance of this work increases due to the COVID-19 pandemic we are going through, so this work can be proposed to contribute to monitoring patients’ cases and considered as a new equipment in studying temperature sensor in human.

1 May 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
DRD A Resen
D A Resen
SKS A Kadhim
S A Kadhim
ALA T Lateef
A T Lateef
AMAseel Mahmood
Aseel Mahmood

1 September 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
SKShehab A Kadhim
Shehab A Kadhim
KKKarrar A Kazr
Karrar A Kazr
AAAlaa H Ali
Alaa H Ali
AMAseel Mahmood
Aseel Mahmood
The technological progress in the means of transmission of information is very fast and it became necessary to obtain high speed in data transmission and high rate of data. Therefore, optical communication systems are the leading methods in this field because they cover these needs, but despite all these characteristics, there is a problem, And we will get rid of this problem in practice in this research through the use of two separate and different wavelengths and connect them to the Wavelength Division Multiplexing and send them to a distance of 3 Km and calculate the amount of dispersion in the signal to the outside of the Optical spectrum analyzer with and without Optical Fiber Bragg Gratings.