Shiqi Liu

Dr. Shiqi Liu


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

20 November 2024 in Journal of Neural Engineering
Verified
Journal Article
Closed access
Chayut BunterngchitChayut Bunterngchit
Chayut Bunterngchit
JWJiaxing Wang
Jiaxing Wang
JSJianqiang Su
Jianqiang Su
YWYihan Wang
Yihan Wang
SLShiqi Liu
Shiqi Liu
ZHZeng-Guang Hou
Zeng-Guang Hou
Objective. Methods that can detect brain activities accurately are crucial owing to the increasing prevalence of neurological disorders. In this context, a combination of electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) offers a powerful approach to understanding normal and pathological brain functions, thereby overcoming the limitations of each modality, such as susceptibility to artifacts of EEG and limited temporal resolution of fNIRS. However, challenges such as class imbalance and inter-class variability within multisubject data hinder their full potential. Approach. To address this issue, we propose a novel temporal attention fusion network (TAFN) with a custom loss function. The TAFN model incorporates attention mechanisms to its long short-term memory and temporal convolutional layers to accurately capture spatial and temporal dependencies in the EEG–fNIRS data. The custom loss function combines class weights and asymmetric loss terms to ensure the precise classification of cognitive and motor intentions, along with addressing class imbalance issues. Main results. Rigorous testing demonstrated the exceptional cross-subject accuracy of the TAFN, exceeding 99% for cognitive tasks and 97% for motor imagery (MI) tasks. Additionally, the ability of the model to detect subtle differences in epilepsy was analyzed using scalp topography in MI tasks. Significance. This study presents a technique that outperforms traditional methods for detecting high-precision brain activity with subtle differences in the associated patterns. This makes it a promising tool for applications such as epilepsy and seizure detection, in which discerning subtle pattern differences is of paramount importance.

18 September 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HLHao Li
Hao Li
XZXiao-Hu Zhou
Xiao-Hu Zhou
Xiaoliang XieXiaoliang Xie
Xiaoliang Xie
SLShiqi Liu
Shiqi Liu
ZFZhen-Qiu Feng
Zhen-Qiu Feng
ZHZeng-Guang Hou
Zeng-Guang Hou
The robot-assisted intervention has shown reduced radiation exposure to physicians and improved precision in clinical trials. However, existing vascular robotic systems follow master-slave control mode and entirely rely on manual commands. This article proposes a novel offline reinforcement learning algorithm, Conservative Actor–critic with SmOoth Gradient (CASOG), to learn manipulation skills on vascular robotic systems. The proposed algorithm conservatively estimates Q-function and smooths gradients of convolution layers to deal with distribution shift and overfitting issues. Furthermore, to focus on complex manipulations, transitions with larger absolute temporal-difference error are sampled with higher probability. Comparative experiments on multiple vascular models and offline data demonstrate that CASOG delivers guidewire to the target with higher success rates and fewer backward steps than prior offline reinforcement learning methods. These results indicate that the proposed algorithm is promising to improve the autonomy of vascular robotic systems.

31 January 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MGMei-Jiang Gui
Mei-Jiang Gui
XZXiao-Hu Zhou
Xiao-Hu Zhou
Xiaoliang XieXiaoliang Xie
Xiaoliang Xie
SLShiqi Liu
Shiqi Liu
HLHao Li
Hao Li
ZHZeng-Guang Hou
Zeng-Guang Hou
Robotic tactile sensing plays a vital role in realizing the precise perception of complex environments, affecting the application of robots in a wide range of industrial and household fields. However, existing tactile sensors are limited by weakly interpretable information mapping relationships. In this article, a novel Halbach-cylinder-based magnetic skin is constructed with permanent magnets and elastic rubber to address such problems. Furthermore, a highly interpretable and widely applicable method is deduced to effectively represent the skin’s information conversion as a Halbach cylinder deforms to an elliptical cylinder under external force. Experiments of simulated models and actual skins with different compressions are conducted to evaluate the proposed method. The results show that 0.24% and 0.26% relative errors in simulated and real environments, respectively, can be achieved. Our method can reach the minimum error in almost all situations compared with state-of-the-art approaches. These promising results demonstrate the method’s great potential to provide a basis for developing a practical magnetic-force mapping relationship.

6 October 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RLRui-Qi Li
Rui-Qi Li
Xiaoliang XieXiaoliang Xie
Xiaoliang Xie
XZXiao-Hu Zhou
Xiao-Hu Zhou
SLShiqi Liu
Shiqi Liu
ZNZhen-Liang Ni
Zhen-Liang Ni
ZHZeng-Guang Hou
Zeng-Guang Hou
Objective: In this paper, Keypoint Localization Region-based CNN (KL R-CNN) is proposed, which can simultaneously accomplish the guidewire detection and endpoint localization in a unified model. Methods: KL R-CNN modifies Mask R-CNN by replacing the mask branch with a novel keypoint localization branch. Besides, some settings of Mask R-CNN are also modified to generate the keypoint localization results at a higher detail level. At the same time, based on the existing metrics of Average Precision (AP) and Percentage of Correct Keypoints (PCK), a new metric named AP PCK is proposed to evaluate the overall performance on the multi-guidewire endpoint localization task. Compared with existing metrics, AP PCK is easy to use and its results are more intuitive. Results: Compared with existing methods, KL R-CNN has better performance when the threshold is loose, reaching a mean AP PCK of 90.65% when the threshold is 9 pixels. Conclusion: KL R-CNN achieves the state-of-the-art performance on the multi-guidewire endpoint localization task and has application potentials. Significance: KL R-CNN can achieve the localization of guidewire endpoints in fluoroscopy images, which is a prerequisite for computer-assisted percutaneous coronary intervention. KL R-CNN can also be extended to other multi-instrument localization tasks.

28 November 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
CFChen-Chen Fan
Chen-Chen Fan
HYHongjun Yang
Hongjun Yang
CZChutian Zhang
Chutian Zhang
LPLiang Peng
Liang Peng
XZXiao-Hu Zhou
Xiao-Hu Zhou
ZHZeng-Guang Hou
Zeng-Guang Hou
Recent advances in deep learning have led to increased adoption of convolutional neural networks (CNN) for structural magnetic resonance imaging (sMRI)-based Alzheimer’s disease (AD) detection. AD results in widespread damage to neurons in different brain regions and destroys their connections. However, current CNN-based methods struggle to relate spatially distant information effectively. To solve this problem, we propose a graph reasoning module (GRM), which can be directly incorporated into CNN-based AD detection models to simulate the underlying relationship between different brain regions and boost AD diagnosis performance. Specifically, in GRM, an adaptive graph Transformer (AGT) block is designed to adaptively construct a graph representation based on the feature map given by CNN, a graph convolutional network (GCN) block is adopted to update the graph representation, and a feature map reconstruction (FMR) block is built to convert the learned graph representation to a feature map. Experimental results demonstrate that the insertion of the GRM in the existing AD classification model can increase its balanced accuracy by more than 4.3%. The GRM-embedded model achieves state-of-the-art performance compared with current deep learning-based AD diagnosis methods, with a balanced accuracy of 86.2%.