Xiaochi Liu

Dr. Xiaochi Liu


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2021 in Optics Express
Verified
Journal Article
Open access
PDF file
XLXiaochi Liu
Xiaochi Liu
YLYa-Nan Lv
Ya-Nan Lv
SKSongbai Kang
Songbai Kang
CZChang-Ling Zou
Chang-Ling Zou
JDJunyi Duan
Junyi Duan
JQJifeng Qu
Jifeng Qu
Coherent population trapping (CPT) resonance signals have promise in a wide range of applications involving precision sensing. Generally, the CPT phenomenon occurs in a three-level Λ system with a bichromatic phase-coherent light fields. We theoretically and experimentally studied an Rb vapor-cell-based atomic system involving bichromatic CPT optical fields and an external microwave (MW) field simultaneously. In such a mixing scheme, the coherence of the ground states could be controlled either by the Rabi frequency of the microwave field or by the relative phase between the optical fields and the MW field. Moreover, we investigated the Rabi resonance in this mixing scheme. The Rabi frequency of the MW field can be measured SI (International System of Units)-traceably based on the Rabi resonance lineshape, and thus holds the potential to realize intensity stabilization of the optical field in this system. Simple theoretical models and numerical calculations are also presented to explain the experimental results. There is scope to use the proposed technique in future development of SI-traceable optical field strength standards.

27 February 2024 in Optics Express
Verified
Journal Article
Closed access
ZYZhilong Yu
Zhilong Yu
YZYumeng Zhu
Yumeng Zhu
MYMinghao Yao
Minghao Yao
FQFeng Qi
Feng Qi
LCLiang Chen
Liang Chen
XLXiaochi Liu
Xiaochi Liu
The grating-based magneto-optical trap (GMOT) is a promising approach for miniaturizing cold-atom systems. However, the power consumption of a GMOT system dominates its feasibility in practical applications. In this study, we demonstrated a GMOT system based on planar elements that can operate with low power consumption. A high-diffraction-efficiency grating chip was used to cool atoms with a single incident beam. A planar coil chip was designed and fabricated with a low power consumption nested architecture. The grating and coil chips were adapted to a passive pump vacuum chamber, and up to 106 87Rb atoms were trapped. These elements effectively reduce the power consumption of the GMOT and have great potential for applications in practical cold-atom-based devices.

6 February 2025 in Optics Express
Verified
Journal Article
Closed access
LXLei Xu
Lei Xu
MLMuming Li
Muming Li
ZYZhilong Yu
Zhilong Yu
ZLZheyu Liu
Zheyu Liu
JDJunyi Duan
Junyi Duan
XLXiaochi Liu
Xiaochi Liu
This paper proposes a dual-color grating chip design method for simultaneously capturing dual atomic clouds (87Rb and 133Cs). By simulating key parameters such as the grating period, etching depth, duty cycle, coating material, and thickness, the optimal design parameters were determined (T = 210 nm, r = 0.5, h0 = 100 nm, d = 1150 nm) to ensure efficient dual-wavelength diffraction and maximize the number of captured atoms. Experimental results demonstrate the simultaneous trapping of 1.6 × 108 87Rb atoms and 7.8 × 106 133Cs atoms, thereby offering an approach for multi-species cold atom systems. This dual-species grating magneto-optical trap (GMOT) system has potential applications in precision measurements such as cold atom clocks, quantum interferometers, and quantum electrometry.

5 January 2023 in Optics Express
Verified
Journal Article
Closed access
ZFZhigang Feng
Zhigang Feng
XLXiaochi Liu
Xiaochi Liu
YZYingyun Zhang
Yingyun Zhang
WRWeimin Ruan
Weimin Ruan
ZSZhenfei Song
Zhenfei Song
JQJifeng Qu
Jifeng Qu
We present an atom-based approach for determining microwave electric and magnetic fields by using a single rubidium vapor cell in a microwave waveguide. For a 87Rb cascade three-level system employed in our experiment, a weak probe laser driving the lower transition, 5S1/2→5P3/2, is first used to measure the microwave magnetic field based on the atomic Rabi resonance. When a counter-propagating strong coupling laser is subsequently turned on to drive the Rydberg transition, 5P3/2→67D5/2, the same probe laser is then used as a Rydberg electromagnetically induced transparency (EIT) probe to measure the microwave electric field by investigating the resonant microwave dressed Autler-Townes splitting (ATS). By tuning the hyperfine transition frequency of the ground state using an experimentally feasible static magnetic field, we first achieved a measurement of the microwave electric and magnetic field strength at the same microwave frequency of 6.916 GHz. Based on the ideal relationship between the electric and magnetic field components, we obtained the equivalent microwave magnetic fields by fitting the inversion to the measured microwave electric fields, which demonstrated that the results were in agreement with the experimental measurement of the microwave magnetic fields in the same microwave power range. This study provides new experimental evidence for quantum-based microwave measurements of electric and magnetic fields by a single sensor in the same system.

5 February 2024 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
ZYZhilong Yu
Zhilong Yu
LCLang Chen
Lang Chen
JDJunyi Duan
Junyi Duan
MYMinghao Yao
Minghao Yao
NTNing Tan
Ning Tan
XLXiaochi Liu
Xiaochi Liu
The grating magneto-optical trap (GMOT) is a promising approach for miniaturizing cold-atom systems. We demonstrated a real-time parameter optimization and drift-mitigation method for a GMOT system based on Bayesian learning. In a remarkable short convergence period, optimal numbers of cold atoms reached up to 7.7 × 106, which was nearly four times better than with manual optimization. The parameters included not only physical parameters but also mechanical parameters that can control the critical optical alignment. The results experimentally demonstrate that our work can efficiently optimize multiple parameters for a GMOT system and for the atom-based systems that need fine control. The machine learner employed a dual layer Bayesian learning, which could suppress the cost function drift due to the instability of the experimental parameters and environmental factors of the GMOT. The proposed approach validates the feasibility of Bayesian optimization in multiparameter cold-atom systems and can be applied to rapidly determine optimal parameters and high stability of general cold atom-based physical systems.

6 June 2022 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
LCLang Chen
Lang Chen
MYMinghao Yao
Minghao Yao
YSYang Shi
Yang Shi
JDJunyi Duan
Junyi Duan
SKSongbai Kang
Songbai Kang
XLXiaochi Liu
Xiaochi Liu
The present Rabi resonance microwave sensing technique cannot fully describe the microwave magnetic field strength distribution due to the signal detection method. Here, we propose an alternative Rabi resonance-based microwave imaging technique using a digital micromirror device and an alkali atomic cell. The experimental results well describe the distribution of the microwave field quantitatively and agree with the absorption imaging results. This technique can also be used as a method to analyze and measure the relaxation rate in an atomic vapor cell and offers a SI-traceable imaging approach for the microwave magnetic field. Its simple architecture holds great potential for the development of compact/miniature microwave field sensors.