Objectives Occupational factors, particularly night-shift work, are attracting growing interest as a possible determinant of metabolic syndrome (MetS). This study aimed to determine the association between night-shift work and MetS, and assess whether sleep quality is a mediating factor. Methods A cross-sectional study was conducted among Malaysian manufacturing workers, aged 40–65 years old. They completed a self-administered questionnaire on sociodemographics, lifestyle and family history, and the Pittsburgh Sleep Quality Index (PSQI) questionnaire. Waist circumference, blood pressure, fasting blood sugar, triglycerides and high-density lipoprotein levels were measured. Baron and Kenny’s method, Sobel test and multiple mediation models with bootstrapping were used to determine whether the PSQI global score or its components mediated the association between night-shift work and MetS. Results Of the 494 participants, 177 (36%) worked night shift and 51% were men. The prevalence of MetS was 37%. Night-shift work was independently associated with a twofold increase in the risk of MetS (adjusted OR: 1.92, 95% CI 1.24 to 2.97). However, the association between night-shift work and MetS did not appear to be modified by sex. Night-shift workers also reported significantly poorer sleep quality, longer sleep latency, shorter sleep duration, sleep disturbances and daytime dysfunction. Robust mediation analysis nonetheless showed that neither PSQI global score nor its components mediated the association between night-shift work and MetS. Conclusion Early screening and management of MetS and the development of programmes to improve sleep quality should be carried out among night-shift workers. Future research should investigate other modifiable mediators linking night-shift work and MetS.
Objectives Night-shift work may adversely affect health. This study aimed to determine the impact of night-shift work on health-related quality of life (HRQoL), and to assess whether sleep quality was a mediating factor. Design A cross-sectional study. Setting 11 manufacturing factories in Malaysia. Participants 177 night-shift workers aged 40–65 years old were compared with 317 non-night-shift workers. Primary and secondary outcomes Participants completed a self-administered questionnaire on socio-demographics and lifestyle factors, 12-item Short Form Health Survey V.2 (SF-12v2) and the Pittsburgh Sleep Quality Index (PSQI). The Baron and Kenny’s method, Sobel test and multiple mediation model with bootstrapping were applied to determine whether PSQI score or its components mediated the association between night-shift work and HRQoL. Results Night-shift work was associated with sleep impairment and HRQoL. Night-shift workers had significantly lower mean scores in all the eight SF-12 domains (p<0.001). Compared with non-night-shift workers, night-shift workers were significantly more likely to report poorer sleep quality, longer sleep latency, shorter sleep duration, sleep disturbances and daytime dysfunction (p<0.001). Mediation analyses showed that PSQI global score mediated the association between night-shift work and HRQoL. ‘Subjective sleep quality’ (indirect effect=−0.24, SE=0.14 and bias corrected (BC) 95% CI −0.58 to −0.01) and ‘sleep disturbances’ (indirect effect=−0.79, SE=0.22 and BC 95% CI −1.30 to −0.42) were mediators for the association between night-shift work and physical well-being, whereas ‘sleep latency’ (indirect effect=−0.51, SE=0.21 and BC 95% CI −1.02 to −0.16) and ‘daytime dysfunction’ (indirect effect=−1.11, SE=0.32 and BC 95% CI −1.86 to −0.58) were mediators with respect to mental well-being. Conclusion Sleep quality partially explains the association between night-shift work and poorer HRQoL. Organisations should treat the sleep quality of night-shift workers as a top priority area for action to improve their employees’ overall wellbeing.
Objective: Facial anthropometric data is important for the design of respirators. Two-dimensional (2D) photogrammetry has replaced direct anthropometric method, but the reliability and accuracy of 2D photogrammetry has not been quantified. This study aimed to assess inter-rater reliability of 2D photogrammetry and to examine the reliability and accuracy of 2D photogrammetry with direct measurement.Design: A cross-sectional study.Setting: Malaysia.Participants: A subset of 96 participants aged 18 and above.Primary and secondary outcomes: Ten facial dimensions were measured using direct measurement and 2D photogrammetry. An assessment of inter-rater reliability was performed using intra-class correlation (ICC) of the 2D images. In addition, ICC and Bland-Altman analyses were used to assess the reliability and agreement of 2D photogrammetry with direct measurement.Results: Except for head breadth and bigonial breadth, which were also found to have low inter-rater reliability, there was no significant difference in the inter-rater mean value of the 2D photogrammetry. The mean measurements derived from direct measurement and 2D photogrammetry were mostly similar. However, statistical differences were noted for two facial dimensions, i.e., bizygomatic breadth and bigonial breadth, and clinically the magnitude of difference was also significant. There were no statistical differences in respect to the remaining eight facial dimensions, where the smallest mean difference was 0.3 mm and biggest mean difference was 1.0 mm. The ICC showed head breadth had poor reliability, whilst Bland-Altman analyses showed seven out of 10 facial dimensions using 2D photogrammetry were accurate, as compared to direct measurement.Conclusion: Only certain facial measurements can be reliably and accurately measured using 2D photogrammetry, thus it is important to conduct a reliability and validation study before the use of any measurement methods in anthropometric studies. The results of this study also suggest that 2D photogrammetry can be used to supplement direct measurement for certain facial dimensions.
Background: Existing anthropometric studies for respirator designs are based on the head and facial dimensions of Americans and Chinese nationals, with no studies for multi-ethnic countries like Malaysia. This study aimed to create head and facial morphological database for Malaysia, specifically to identify morphological differences between genders, ethnicities, and birthplaces, as well as predictors of the dimensions.Design: A cross-sectional study.Setting: Malaysia.Participants: A nation-wide cross-sectional study using a complex survey design with two stage-stratified random sampling was conducted among 3,324 participants, aged 18 years and above who were also participants of the National Health and Morbidity Survey 2020.Primary and secondary outcomes: The study collected data on sociodemographic, measurement of Body Mass Index (BMI) and 10 head and facial dimensions (3 dimensions were measured using direct measurement, and 7 others using Digimizer software for 2-dimension images). Linear regression was performed to determine the association between gender, ethnicity, birthplace, age and BMI and the dimensions.Results: There were significant differences in all the dimensions between sex, birthplace and ethnicity (p < 0.005). Further analysis using linear regression showed sex, ethnicity, birthplace, age and BMI were significant predictors of the dimensions. In comparison to studies from the United States and China, our study population had a wider interpupillary distance and nose breadth for both male and female participants, but smaller bigonial breadth and smaller minimal frontal breadth.Conclusion: These findings could assist in the design and sizing of respirators that will fit Malaysians and possibly other Southeast Asian population.
This study examined the association of various brands of NIOSH-certified N95 filtering face-piece respirators (FFR) fit with facial dimensions and gender. One hundred and thirty-five participants (77 females and 58 males) were recruited from the previous facial anthropometry study among Malaysians in 2020. Quantitative respirator fit testing of six FFR were performed using the TSI Portacount Pro+ 8038 which comprised of four exercises (bending over, talking, up-down head movement, and side to side head movement). An overall fit factor (FF) of ≥ 100 was considered a pass for each FFR. Analysis was done using T-test, Pearson’s correlations, and generalised linear regression. The passing rates for the six FFR were 36.3% (Cup B), 50.4% (Trifold A), 54.1% (Duckbill A), 57.0% (Cup A), 74.1% (Trifold B), and 83.7% (Duckbill B). Both Duckbill B and Trifold B had the highest passing rates for both genders. However, certain FFR models (Cup B, Trifold A, Trifold B, and Duckbill A) fit better for participants with large facial size who were mostly males, while others (Cup A and Duckbill B) specifically fit better for those with small facial size, who were mostly females. This study showed significant positive effect of nose protrusion, nasal root and subnasale-sellion and the negative effect of menton-sellion, bigonial breadth and nose breadth on fit factors of various FFR. The results of this study emphasized the importance of choosing and designing FFR based on local anthropometry data, with careful consideration on the dimensions that affect the respirator fit. Since N95 are commonly used in the healthcare settings to prevent airborne transmission, the practice of respirator fit testing and selecting N95 with high passing rates for healthcare workers need to be emphasized.
Background: Post Acute COVID Syndrome (PACS), a complex and poorly understood condition characterised by persistent symptoms following the acute phase of COVID-19 infection, has emerged as a significant global health concern. Healthcare workers who had been at the forefront of the pandemic response are at heightened risk of contracting the virus and subsequently developing PACS. Therefore, we aim to determine the prevalence and risk factors for PACS among healthcare workers infected with COVID-19.Methods: A cross-sectional study was conducted between October 2022 and August 2023 using an online REDCap electronic data capture tool questionnaire. PACS was defined as new or persistent symptoms lasting more than 28 days after a positive SARS-CoV-2 polymerase chain reaction or rapid test kit antigen test. Multivariable logistic regression was performed to determine predictors associated with PACS.Results: Among 609 infected healthcare workers, they were predominantly female (71.8%), Malays (84.6%), and aged 18–39 years (70.1%). 50.7% of infected healthcare workers experienced PACS. The most common PACS symptoms experienced were fatigue (27.9%), cough (25.1%), decreased physical strength (20.5%), and musculoskeletal pain (19.2%). Those who are more likely to develop PACS were females, underlying asthma, and COVID-19 severity category 3. On the other hand, those who received booster vaccinations were less likely to develop PACS.Conclusion: PACS is prevalent among healthcare workers with COVID-19 at the University Malaya Medical Centre. These findings emphasise the critical need for those with higher risk to receive regular health monitoring and checkups to detect any early signs of PACS. It underscores the need for continuous support and healthcare interventions to mitigate the impacts of PACS and ensure the physical and mental well-being of healthcare workers.