18 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
AMArmando Rodrigo Mor
Armando Rodrigo Mor
LHLuis Carlos Castro Heredia
Luis Carlos Castro Heredia
FMFabio Munoz
Fabio Munoz
This paper presents a novel measuring system for partial discharge (PD) measurements in Gas Insulated Systems (GIS) using high frequency current transformers (HFCT). The system is based on the measurement of the induced PD currents in the GIS enclosure. In opposition to the existing antenna technologies that measure the radiated energy in the very high frequency/ultra-high frequency (VHF/UHF) range, the proposed system measures the PD conducted currents in the high frequency (HF) range and below. The foundation of the measurements together with a detailed explanation of the sensor installed conveniently at the bolts of the GIS spacer are presented. An experimental study on the current distribution in the GIS enclosure is described to evaluate the impact of the sensor on the measurements. Laboratory experiments have been performed that show the suitability of this method to properly measure particle discharges caused by corona, surface and free moving particle discharges in SF6. Discharges in the range of 1 to 4 pC have been properly measured. An analysis to evaluate the performance of the method is shown, in comparison to VHF/UHF antenna measurements. The potential benefits of this novel technique rely on the small attenuation of PD signals in the GIS components in the HF range and sample rate reductions. Finally, a discussion on the potential applicability of present cluster and charge calculation techniques to the proposed PD GIS measurement using HFCT is presented.

29 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
AMArmando Rodrigo Mor
Armando Rodrigo Mor
FMFabio Munoz
Fabio Munoz
LHLuis Carlos Castro Heredia
Luis Carlos Castro Heredia
This paper describes a simplified model and a generic model of high-frequency current transformer (HFCT) sensors. By analyzing the models, a universal charge estimation method based on the double time integral of the measured voltage is inferred. The method is demonstrated to be valid irrespective of HFCT sensor, assuming that its transfer function can be modelled as a combination of real zeros and poles. This paper describes the mathematical foundation of the method and its particularities when applied to measure nanosecond current pulses. In practice, the applicability of the method is subjected to the characteristics and frequency response of the sensor and the current pulse duration. Therefore, a proposal to use the double time integral or the simple time integral of the measured voltage is described depending upon the sensor response. The procedures used to obtain the respective calibration constants based on the frequency response of the HFCT sensors are explained. Two examples, one using a HFCT sensor with a broadband flat frequency response and another using a HFCT sensor with a non-flat frequency response, are presented.

14 September 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
TVThanh Vu-Cong
Thanh Vu-Cong
CTCaterina Toigo
Caterina Toigo
FJFrank Jacquier
Frank Jacquier
AGAlain Girodet
Alain Girodet
MTMaximilian Nikolaus Tuczek
Maximilian Nikolaus Tuczek
AMArmando Rodrigo Mor
Armando Rodrigo Mor
This paper investigates partial discharge (PD) behavior of protrusion defects in real size High Voltage Direct Current Gas Insulated Switchgear (HVDC GIS) for SF 6 and SF 6 alternative gases including Fluoronitrile – CO 2 mixture (10 %) and Fluoroketone – Dry Air mixture (6.6 %). The evolution of PD apparent charge and PD repetition rate for all investigated gases is presented and discussed. The measurement results indicate that PD behavior changes as a function of time. The PD apparent charge increases and the PD repetition rate decreases with the increase of voltage application time. This evolution can be related to the change in protrusion tip radius due to electrochemical etching: Radius of the protrusion’s tip being enlarged. Additionally, the Pulse Sequence Analysis (PSA) plots of the PDs caused by this defect are presented. It is observed that the PSA plots change over time. Therefore, for the development of a robust PD monitoring and defect recognition tool, as well as for the assessment of risks in the operation of HVDC GIS, it is crucial to take these changes into account.

19 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
AMArmando Rodrigo Mor
Armando Rodrigo Mor
FMFabio Munoz
Fabio Munoz
LHLuis Carlos Castro Heredia
Luis Carlos Castro Heredia
This paper presents a new concept for partial discharge measurements in gas insulated systems (GIS). The proposed technique uses a novel GIS magnetic antenna that measures the magnetic field produced by partial discharges (PD) propagating in GIS. The foundations of the measurement technique and the magnetic antenna design are presented together with laboratory measurements. The magnetic antenna performance and the sensitivity of the acquisition system are studied. The bandwidth of the measurement system is in the high frequency and very high frequency (HF–VHF) range. Laboratory experiments demonstrate the suitability of the novel magnetic antenna-based measuring system for PD in GIS for corona, surface discharges, and free moving particles in SF6.

26 November 2017 in Energies
Verified
Journal Article
Open access
PDF file
Aditya ShekharAditya Shekhar
Aditya Shekhar
XFXianyong Feng
Xianyong Feng
AGAngelo Gattozzi
Angelo Gattozzi
Robert HebnerRobert Hebner
Robert Hebner
DWDouglas Wardell
Douglas Wardell
Pavol BauerPavol Bauer
Pavol Bauer
A scientific consensus is emerging on the benefits of direct current (DC) distribution in medium voltage (MV) power systems of ships and cities. At least 50% space savings and increased power transfer capacity are estimated with enhanced voltage DC operation of electric cables. The goal of this research is to contribute to developing the empirical knowledge on the insulation performance in order to validate the feasibility of such anticipated gains of DC versus alternating current (AC), and to determine the comparative impact of different operational conditions from a component engineering point of view. The partial discharge (PD) activity in cables is measured under AC and DC conditions as an indicator of insulation performance. Specifically, PDs in defects at the semicon-insulation interface are studied in terms of inception voltage, repetition rate and discharge magnitude. Empirical understanding is drawn for operating voltage and frequency dependence of the discharge behavior in such voids in the range of 10 to 20 kV and 0 to 0.1 Hz, respectively. The change in PD activity with void evolution post temperature-induced ageing process is explored.

1 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
GMGuillermo Mier
Guillermo Mier
AMArmando Rodrigo Mor
Armando Rodrigo Mor
PVPeter Vaessen
Peter Vaessen
Nowadays, the use of several methods for the measurement of space charges in dielectrics has become more relevant. The availability of different space charge measurement methods brings the necessity of calibration and characterization of measurement equipment to reach standardized measurements. In this paper, a method is presented to apply known charges at built samples which can be used for acoustic and thermal methods to compare measured values with calibration purposes. Experimental tests for validation purposes were performed in flat samples by comparison of results between a single layer and multilayer samples. Moreover, this method can be used to measure the resolution and accuracy of space charge measurement systems.