Ann Elizabeth Perreau

Dr. Ann Elizabeth Perreau

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Journal of the American Academy of Audiology
Verified
Journal Article
Open access
PDF file
APAnn Elizabeth Perreau
Ann Elizabeth Perreau
YWYu-Hsiang Wu
Yu-Hsiang Wu
BTBailey Tatge
Bailey Tatge
DIDiana Irwin
Diana Irwin
DCDaniel Corts
Daniel Corts
Background:Studies have examined listening effort in individuals with hearing loss to determine the extent of the impairment. Regarding cochlear implants (CIs), results suggest that listening effort is improved using bilateral CIs compared to unilateral CIs. Few studies have investigated listening effort and outcomes related to the hybrid CI.Purpose:Here, we compared listening effort across three CI groups, and to a normal-hearing control group. The impact of listener traits, that is, age, age at onset of hearing loss, duration of CI use, and working memory capacity, were examined relative to listening effort.Research Design:The participants completed a dual-task paradigm with a primary task identifying sentences in noise and a secondary task measuring reaction time on a Stroop test. Performance was assessed for all participant groups at different signal-to-noise ratios (SNRs), ranging in 2-dB steps from 0 to +10 dB relative to an individual’s SNR-50, at which the speech recognition performance is 50% correct. Participants completed three questions on listening effort, the Spatial Hearing Questionnaire, and a reading span test.Study Sample:All 46 participants were adults. The four participant groups included (1) 12 individuals with normal hearing, (2) 10 with unilateral CIs, (3) 12 with bilateral CIs, and (4) 12 with a hybrid short-electrode CI and bilateral residual hearing.Data Collection and Analysis:Results from the dual-task experiment were compared using a mixed 4 (hearing group) by 6 (SNR condition) analysis of variance (ANOVA). Questionnaire results were compared using one-way ANOVAs, and correlations between listener traits and the objective and subjective measures were compared using Pearson correlation coefficients.Results:Significant differences were found in speech perception among the normal-hearing and the unilateral and the bilateral CI groups. There was no difference in primary task performance among the hybrid CI and the normal-hearing groups. Across the six SNR conditions, listening effort improved to a greater degree for the normal-hearing group compared to the CI groups. However, there was no significant difference in listening effort between the CI groups. The subjective measures revealed significant differences between the normal-hearing and CI groups, but no difference among the three CI groups. Across all groups, age was significantly correlated with listening effort. We found no relationship between listening effort and the age at the onset of hearing loss, age at implantation, the duration of CI use, and working memory capacity for these participants.Conclusions:Listening effort was reduced to a greater degree for the normal-hearing group compared to the CI users. There was no significant difference in listening effort among the CI groups. For the CI users in this study, age was a significant factor with regard to listening effort, whereas other variables such as the duration of CI use and the age at the onset of hearing loss were not significantly related to listening effort.

1 February 2013 in Journal of the American Academy of Audiology
Verified
Journal Article
Closed access
APAnn Elizabeth Perreau
Ann Elizabeth Perreau
RBRuth A. Bentler
Ruth A. Bentler
Richard Sydney TylerRichard Sydney Tyler
Richard Sydney Tyler
Background:Frequency-lowering signal processing in hearing aids has re-emerged as an option to improve audibility of the high frequencies by expanding the input bandwidth. Few studies have investigated the usefulness of the scheme as an option for bimodal users (i.e., combined use of a cochlear implant and a contralateral hearing aid). In this study, that question was posed.Purpose:The purposes of this study were (1) to determine if frequency compression was a better bimodal option than conventional amplification and (2) to determine the impact of a frequency-compression hearing aid on speech recognition abilities.Research Design:There were two separate experiments in this study. The first experiment investigated the contribution of a frequency-compression hearing aid to contralateral cochlear implant (CI) performance for localization and speech perception in noise. The second experiment assessed monaural consonant and vowel perception in quiet using the frequency-compression and conventional hearing aid without the use of a contralateral CI or hearing aid.Study Sample:Ten subjects fitted with a cochlear implant and hearing aid participated in the first experiment. Seventeen adult subjects with a cochlear implant and hearing aid or two hearing aids participated in the second experiment. To be included, subjects had to have a history of postlingual deafness, a moderate or moderate-to-severe hearing loss, and have not worn this type of frequency-lowering hearing aid previously.Data Collection and Analysis:In the first experiment, performance using the frequency-compression and conventional hearing aids was assessed on tests of sound localization, speech perception in a background of noise, and two self-report questionnaires. In the second experiment, consonant and vowel perception in quiet was assessed monaurally for the two conditions. In both experiments, subjects alternated daily between a frequency-compression and conventional hearing aid for 2 mo. The parameters of frequency compression were set individually for each subject, and audibility was measured for the frequency compression and conventional hearing aid programs by comparing estimations of the Speech Intelligibility Index (SII) using a modified algorithm (Bentler et al, 2011). In both experiments, the outcome measures were administered following the hearing aid fitting to assess performance at baseline and after 2 mo of use.Results:For this group of subjects, the results revealed no significant difference between the frequency-compression and conventional hearing aid on tests of localization and consonant recognition. Spondee-in-noise and vowel perception scores were significantly higher with the conventional hearing aid compared to the frequency-compression hearing aid after 2 mo of use.Conclusions:These results suggest that, for the subjects in this study, frequency compression is not a better bimodal option than conventional amplification. In addition, speech perception may be negatively influenced by frequency compression because formant frequencies are too severely compressed and can no longer be distinguished.

1 December 2014 in American Journal of Audiology
Verified
Journal Article
Closed access
APAnn Elizabeth Perreau
Ann Elizabeth Perreau
HOHua Ou
Hua Ou
Richard Sydney TylerRichard Sydney Tyler
Richard Sydney Tyler
CDCamille Dunn
Camille Dunn
Purpose: The goal of this study was to determine how self-reported spatial hearing abilities differ across various cochlear implant (CI) profiles and to examine the degree of subjective benefit following cochlear implantation across different groups of CI users. Method: This was a retrospective study of subjective spatial hearing ability of CI recipients. The subjects consisted of 99 unilateral CI users, 49 bilateral CI users, 32 subjects with a CI and contralateral hearing aid (bimodal users), and 37 short-electrode CI users. All subjects completed the Spatial Hearing Questionnaire (Tyler, Perreau, & Ji, 2009), a questionnaire assessing spatial hearing ability, after implantation, and a subset of the subjects completed the questionnaire pre- and postimplantation. Results: Subjective spatial hearing ability was rated higher for the bilateral and short electrode CI users compared to the unilateral and bimodal users. There was no significant difference in subjective spatial hearing performance between the bilateral and short electrode CI users and the unilateral CI and bimodal users. A separate analysis of pre- and postimplant performance revealed that all CI groups reported significant improvements in spatial hearing ability after implantation. Conclusion: This study suggests that there are substantial differences in perceived spatial hearing ability among unilateral and bimodal CI users compared with bilateral and short electrode CI users.

1 April 2020 in Journal of the American Academy of Audiology
Verified
Journal Article
Closed access
PDF file
APAnn Elizabeth Perreau
Ann Elizabeth Perreau
RTRichard Tyler
Richard Tyler
PMPatricia C. Mancini
Patricia C. Mancini
Background Electrical stimulation of the cochlea to treat tinnitus has been explored for decades. However, few studies have investigated the most salient programming parameters for tinnitus suppression in cochlear implant (CI) patients. Purpose The purpose of this study was to review the available CI programming parameters for tinnitus suppression and to consider possible clinical research designs for selecting the optimal programming parameters for CI patients. Results Across research studies, the optimal parameters vary significantly and are often based on data fromonly a fewparticipants. Electrical stimulation using lowand high rates, different electrode numbers, and low T-levels were helpful in suppressing tinnitus, although more research is needed from a greater number of CI patients. Possible designs for evaluating these parameters in a clinical setting are presented. Conclusions Programming a CI to reduce the prominence of tinnitus is complex, and audiologists should consider adjusting CI parameters systematically for CI patients with bothersome tinnitus.

1 June 2014 in American Journal of Audiology
Verified
Journal Article
Closed access
PDF file
APAnn Elizabeth Perreau
Ann Elizabeth Perreau
BSBryn Spejcher
Bryn Spejcher
HOHua Ou
Hua Ou
Richard Sydney TylerRichard Sydney Tyler
Richard Sydney Tyler
Purpose: Although a number of questionnaires are available to assess hearing aid benefit and general hearing disability, relatively few investigate spatial hearing ability in more complex listening situations. The aim of this study was to document the performance of individuals with normal hearing using the Spatial Hearing Questionnaire (SHQ; Tyler, Perreau, & Ji, 2009) and to compare performance with published data from cochlear implant (CI) users. Method: Fifty-one participants with normal hearing participated. All participants completed the 24-item SHQ. Also, a factor analysis and reliability tests were performed. Results: Performance on the SHQ was high (87%) for the participants with normal hearing. Subjective ratings varied across different listening situations: Understanding speech in quiet (98%) was rated higher than sound localization (84%) and understanding speech in a background of noise (85%). Compared with previously published data (Tyler, Perreau, & Ji, 2009), listeners with normal hearing rated their spatial hearing ability significantly better than bilateral and unilateral CI users. Results confirmed that the SHQ is a reliable measure of spatial hearing ability for listeners with normal hearing. Conclusions: Overall, results indicated that the SHQ is able to capture expected differences between individuals with normal hearing and CI users. These new data can be used as targets following the provision of hearing devices.

1 May 2008 in Journal of the American Academy of Audiology
Verified
Journal Article
Open access
PDF file
Richard Sydney TylerRichard Sydney Tyler
Richard Sydney Tyler
SWShelley A. Witt
Shelley A. Witt
CDCamille C. Dunn
Camille C. Dunn
APAnn Elizabeth Perreau
Ann Elizabeth Perreau
Background: Although we always want to select the best signal-processing strategy for our hearing-aid and cochlear-implant patients, no efficient and valid procedure is available. Comparisons in the office are without listening experience, and short-term take-home trials are likely influenced by the order of strategies tried. Purpose: The purpose of this study was to evaluate a new procedure for comparing signal-processing strategies whereby patients listen with one strategy one day and another strategy the next day. They continue this daily comparison for several weeks. We determined (1) if differences existed between strategies without prior listening experience and (2) if performance differences (or lack there of) obtained at the first listening experience are consistent with performance after two to three months of alternating between strategies on a daily basis (equal listening experience). Research Design: Eight subjects were tested pretrial with a vowel, sentence, and spondee recognition test, a localization task, and a quality rating test. They were required to listen to one of two different signal processing strategies alternating between strategies on a daily basis. After one to three months of listening, subjects returned for follow-up testing. Additionally, subjects were asked to make daily ratings and comments in a diary. Results: Pre-trial (no previous listening experience), a clear trend favoring one strategy was observed in four subjects. Four other subjects showed no clear advantage. Post-trial (after alternating daily between strategies), of the four subjects who showed a clear advantage for one signal processing strategy, only one subject showed that same advantage. One subject ended up with an advantage for the other strategy. Post-trial, of the four subjects who showed no advantage for a particular signal processing strategy, three did show an advantage for one strategy over the other. Conclusion: Patients are willing to alternate between signal processing strategies on a daily basis for up to three months in an attempt to determine their optimal strategy. Although some patients showed superior performance with initial fittings (and some did not), the results of pre-trial comparison did not always persist after having equal listening experience. We recommend this daily alternating listening technique when there is interest in determining optimal performance among different signal processing strategies when fitting hearing aids or cochlear implants.