KiWoong Seong

Dr. KiWoong Seong

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Hearing Research
Verified
Journal Article
Closed access
DSDong Ho Shin
Dong Ho Shin
KSKiWoong Seong
KiWoong Seong
SPSunil Puria
Sunil Puria
KLKyu-Yup Lee
Kyu-Yup Lee
JCJin-Ho Cho
Jin-Ho Cho

1 August 2014 in Hearing Research
Verified
Journal Article
Closed access
JLJangWoo Lee
JangWoo Lee
KSKiWoong Seong
KiWoong Seong
NCNam Hyun Cho
Nam Hyun Cho
KLKyu-Yup Lee
Kyu-Yup Lee
JCJin-Ho Cho
Jin-Ho Cho

20 July 2020 in IEEE Access
Verified
Journal Article
Open access
DSDong Ho Shin
Dong Ho Shin
KSKiWoong Seong
KiWoong Seong
HNHideko Heidi Nakajima
Hideko Heidi Nakajima
SPSunil Puria
Sunil Puria
JCJin-Ho Cho
Jin-Ho Cho
We describe a new implantable hearing-aid output device, a piezoelectric bellows round-window driver (PBRD), which is expected to be unaffected by external magnetic fields. The core elements of the PBRD are a piezoelectric element and a gold-coated copper bellows of low stiffness that transmits piezoelectric displacements, without significant attenuation, to the round window (RW). We analyzed structural and mechanical vibrations when confirming bellows transmission efficiency using a finite element model simulation. The PBRD was bench-tested under no-load conditions to determine its frequency response characteristics. We compared the outputs of the PBRD and a commercial floating-mass transducer in situ in human cadaveric temporal bones with responses measured using a laser Doppler vibrometer. PBRD outputs were excellent at both low (0.1–0.7 kHz) and high (2–16 kHz) frequencies; thus, the PBRD has the potential to compensate for conductive and/or sensorineural hearing loss. The frequency-response performance of the PBRD is better than that of conventional RW drivers (actuators or transducers).

9 September 2015 in Sensors
Verified
Journal Article
Open access
PDF file
SWSeong Tak Woo
Seong Tak Woo
DSDong Ho Shin
Dong Ho Shin
HLHyung Gyu Lim
Hyung Gyu Lim
KSKiWoong Seong
KiWoong Seong
PGPeter Gottlieb
Peter Gottlieb
JCJin-Ho Cho
Jin-Ho Cho
Fully implantable hearing devices (FIHDs) have been developed as a new technology to overcome the disadvantages of conventional acoustic hearing aids. The implantable microphones currently used in FIHDs, however, have difficulty achieving high sensitivity to environmental sounds, low sensitivity to body noise, and ease of implantation. In general, implantable microphones may be placed under the skin in the temporal bone region of the skull. In this situation, body noise picked up during mastication and touching can be significant, and the layer of skin and hair can both attenuate and distort sounds. The new approach presently proposed is a microphone implanted at the tympanic membrane. This method increases the microphone’s sensitivity by utilizing the pinna’s directionally dependent sound collection capabilities and the natural resonances of the ear canal. The sensitivity and insertion loss of this microphone were measured in human cadaveric specimens in the 0.1 to 16 kHz frequency range. In addition, the maximum stable gain due to feedback between the trans-tympanic microphone and a round-window-drive transducer, was measured. The results confirmed in situ high-performance capabilities of the proposed trans-tympanic microphone.

1 January 2020 in IEEE Access
Verified
Journal Article
Open access
SLSeung Hyun Lee
Seung Hyun Lee
KSKiWoong Seong
KiWoong Seong
KLKyu-Yup Lee
Kyu-Yup Lee
DSDong Ho Shin
Dong Ho Shin
We designed and implemented an electromagnetic transducer for implantable bone conduction hearing aids. The proposed transducer is smaller than previous bone conduction transducers for easy implantation and was designed using high permeability metals to produce large electromagnetic forces. In addition, the number of cantilever beams was changed from two to three to minimize distortion of the transducer, potentially due to twisting of the cantilever beam. The proposed transducer consists of a titanium cover with three screw holes, a metal ring, a circular plate, a vibrational membrane with a three-cantilever structure, a metal plate and cylinder, a permanent magnet, top and bottom coils, and a cylindrical titanium case. The transducer was optimally designed based on analysis of electromagnetic and mechanical vibrations, and the target resonance frequency was derived by controlling the variable elements of the vibrational membrane. The transducer was manufactured based on the results of finite element analysis, and the validity of the design was verified by comparing the results of vibration measurement experiments and a simulation. Finally, to evaluate the performance of the proposed transducer, the transducer was attached to the mastoid of participants and functional near-infrared spectroscopy was used to measure brain activation changes of the auditory cortex due to vibration stimulation.

18 August 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DSDong Ho Shin
Dong Ho Shin
JKJong Hoon Kim
Jong Hoon Kim
PGPeter Gottlieb
Peter Gottlieb
YVYona Vaisbuch
Yona Vaisbuch
SPSunil Puria
Sunil Puria
KSKiWoong Seong
KiWoong Seong
Acoustic hearing aids generate amplified sound in the ear canal, and they are the standard of care for patients with mild to moderate sensorineural hearing loss. However, because of their limited frequency bandwidth, gain, and feedback, there is substantial room for improvement. Active middle ear implants, which directly vibrate the middle ear and cochlea, are an alternative approach to conventional acoustic hearing aids. They provide an opportunity to improve sound quality and speech understanding with amplification rehabilitation. For floating-mass type and direct-rod type (DRT) middle ear transducers, a differential floating-mass transducer (DFMT) and a tri-coil bellows transducer (TCBT), respectively, were fabricated to measure the output characteristics in four human temporal bones. Both were fabricated to have similar output forces per unit input and were placed in four human temporal bones to measure their output performances. The TCBT resulted in higher output than did the DFMT throughout the audible frequency range, and the output was more prominent at lower frequency ranges. In this study, we showed that DRT was a more effective method for round window stimulation. Because of its frequency characteristics and vibration efficiency, this implantation method can be utilized as a driving solution for middle ear implants.