Jian Liu

Dr. Jian Liu


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2016 in Journal of Translational Medicine
Verified
Journal Article
Open access
PDF file
CWChao Wang
Chao Wang
ZTZhongbin Tian
Zhongbin Tian
JLJian Liu
Jian Liu
LJLinkai Jing
Linkai Jing
NPNikhil Paliwal
Nikhil Paliwal
XYXinjian Yang
Xinjian Yang
The aim of this study was to quantify the effect of the new Low-profile Visualized Intraluminal Support (LVIS®D) device and the difference of fluid diverting effect compared with the Pipeline device and the Enterprise stent using computational fluid dynamics (CFD). In this research, we simulated three aneurysms constructed from 3D digital subtraction angiography (DSA). The Enterprise, LVIS and the Pipeline device were virtually conformed to fit into the vessel lumen and placed across the aneurysm orifice. Computational fluid dynamics analysis was performed to compare the hemodynamic differences such as WSS, Velocity and Pressure among these stents. Control referred to the unstented model, the percentage of hemodynamic changes were all compared to Control. A single LVIS stent caused more wall shear stress reduction than double Enterprise stents (39.96 vs. 30.51 %) and velocity (23.13 vs. 18.64 %). Significant reduction in wall shear stress (63.88 %) and velocity (46.05 %) was observed in the double-LVIS stents. A single Pipeline showed less reduction in WSS (51.08 %) and velocity (37.87 %) compared with double-LVIS stent. The double-Pipeline stents resulted in the most reduction in WSS (72.37 %) and velocity (54.26 %). Moreover, the pressure increased with minuscule extent after stenting, compared with the unstented model. This is the first study analyzing flow modifications associated with LVIS stents. We found that the LVIS stent has certain hemodynamic effects on cerebral aneurysms: a single LVIS stent caused more flow reductions than the double-Enterprise stent but less than a Pipeline device. Nevertheless, the double-LVIS stent resulted in a better flow diverting effect than a Pipeline device.

19 May 2020 in Translational Stroke Research
Verified
Journal Article
Closed access
PDF file
WZWei Zhu
Wei Zhu
WLWenqiang Li
Wenqiang Li
ZTZhongbin Tian
Zhongbin Tian
YZYisen Zhang
Yisen Zhang
KWKun Wang
Kun Wang
XYXinjian Yang
Xinjian Yang

18 November 2016 in BMC Neurology
Verified
Journal Article
Open access
PDF file
YZYisen Zhang
Yisen Zhang
LJLinkai Jing
Linkai Jing
YZYing Zhang
Ying Zhang
JLJian Liu
Jian Liu
XYXinjian Yang
Xinjian Yang
Few previous hemodynamic studies demonstrated the detailed features of rupture point of intracranial aneurysms. The hemodynamic simulation for the case that ruptured during angiography was even rare. In the present study, we studied the hemodynamic characteristics of a posterior communicating artery segment aneurysm that ruptured during angiography and detailed the hemodynamic features at the rupture point. One 64-years-patient was 60–69 years old and suffered a subarachnoid hemorrhage within 24 h. Standard digital subtraction angiography and three-dimensional (3D) rotational angiography were performed and an 8 mm left posterior communicating artery segment aneurysm was found. The patient had a seizure immediately following 3D angiography for about 40 s and the immediate follow-up angiography showed contrast extravasation from the tip of identified aneurysms. The consequent vital sign of the patient became unstable. Urgent embolization under general anesthesia was planned, but the relatives refused interventional operation considering the high risk of procedure and poor condition of the patient. The computational fluid dynamic (CFD) method was used to evaluate the hemodynamic characteristics at rupture point, and the results showed that the rupture point was associated with markedly low wall shear stress and high oscillatory shear index without flow impingement. We present a rare case of which the rupture site was identified during angiography. The hemodynamic simulations revealed that the rupture point was associated with markedly low WSS and high OSI without flow impingement. The result may be unique to this particular aneurysm; however, our findings provide insight into the hemodynamics of rupture point.

1 December 2021 in Stroke
Verified
Journal Article
Closed access
PDF file
WLWenqiang Li
Wenqiang Li
WZWei Zhu
Wei Zhu
AWAnxin Wang
Anxin Wang
GZGuojun Zhang
Guojun Zhang
YZYisen Zhang
Yisen Zhang
XYXinjian Yang
Xinjian Yang
Background and Purpose: This study tests whether patients with unruptured intracranial aneurysm who underwent stent placement benefitted from platelet function monitoring–guided adjustment of antiplatelet therapy. Methods: We conducted a randomized, open-label, parallel group, assessor-blinded trial. Patients with unruptured intracranial aneurysm who underwent stent placement were assigned in a 1:1 ratio to receive either drug adjustment (patients who had high on-treatment platelet reactivity to antiplatelet therapy on the basis of platelet function monitoring [monitoring group]) or conventional therapy (without monitoring and drug adjustment [conventional group]). The second monitoring was performed 14 days after randomization in patients with drug adjustment. The primary outcome was the composite frequency of ischemic stroke, transient ischemic attack, stent thrombosis, urgent revascularization, and cerebrovascular death within 7 days after stent implantation. The safety outcome was the composite frequency of major, minor, or minimal bleeding within 1 month after stent implantation. Results: In total, 314 patients were included (n=157 per group). The primary combined outcome occurred in 19 patients (12.1%) in the conventional group and 8 patients (5.1%) in the monitoring group (hazard ratio, 0.39 [95% CI, 0.17–0.92]; P =0.03). Ischemic stroke occurred at a lower frequency in the monitoring group compared with that in the conventional group (4.5% versus 12.1%; hazard ratio, 0.34 [95% CI, 0.14–0.83]; P =0.01), which drove the overall primary combined outcome. The safety outcome occurred in the monitoring group (7.0%) and in the conventional group (1.9%; hazard ratio, 3.87 [95% CI, 1.06–14.14]; P =0.03). A significant difference was observed in the frequency of minor or minimal bleeding events between the two groups (monitoring group versus conventional group, 6.4% versus 1.3%; P =0.02) but not in the frequency of major bleeding events between the two groups. Conclusions: Platelet function monitoring–guided antiplatelet therapy reduces thromboembolic events in patients with unruptured intracranial aneurysm after stent placement, significantly enhancing minor or minimal bleeding events but not major bleeding events. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03989557.

26 April 2023 in European Radiology
Verified
Journal Article
Closed access
PDF file
MTMirzat Turhon
Mirzat Turhon
MLMengxing Li
Mengxing Li
HKHuibin Kang
Huibin Kang
JHJiliang Huang
Jiliang Huang
FZFujunhui Zhang
Fujunhui Zhang
JLJian Liu
Jian Liu

1 January 2019 in Clinical and Applied Thrombosis/Hemostasis
Verified
Journal Article
Open access
PDF file
YCYuying Cheng
Yuying Cheng
JLJian Liu
Jian Liu
YSYu Su
Yu Su
HZHuiru Zhao
Huiru Zhao
YZYujing Zhao
Yujing Zhao
JWJun Wu
Jun Wu
One common complication after joint arthroplasty is venous thromboembolism (VTE). Therefore, it is essential to measure the changes in coagulation and fibrinolysis in order to predict VTE among patients who underwent joint arthroplasty. This study aimed to identify potential useful biomarkers for prognosing to VTE. This was a prospective cohort study enrolling 83 patients who underwent joint arthroplasty. The levels of d-dimer, thrombin–antithrombin complex (TAT), plasmin–α2-antiplasmin complex (PIC), soluble thrombomodulin, and tissue plasminogen activator inhibitor complex were measured on day 0 (before surgery) and days 1, 3, and 6 after surgery. Ultrasound examination was used to diagnose VTE on preoperative day 0 and postoperative day 6. A total of 35 patients developed VTE after surgery. Patients with VTE exhibited significantly higher levels of d-dimer and TAT on postoperative days 3 and 6 (all P < .05). The area under curves (AUC) of receiver operating characteristic (ROC) were 0.65 and 0.68 and 0.68 and 0.74 for d-dimer and TAT levels on postoperative days 3 and 6, respectively. The level of TAT/PIC ratio on postoperative day 6 was significantly increased among patients with VTE compared to non-VTE patients (P < .0001). In addition, the AUC of ROC, cutoff level, sensitivity, specificity, positive-predictive value, and negative-predictive value of TAT/PIC ratio were 0.78, 4.03 ng/TU, 97.14%, 33.33%, 51.52%, and 94.12%, respectively. The high sensitivity and negative predictive value of TAT/PIC ratio make it a potential prognostic index for diagnosing VTE during the early phase of postoperative joint arthroplasty.