Suhail Asghar Qureshi

Dr. Suhail Asghar Qureshi

Faculty of Electrical and Electronic Engineering, Universiti Tun Hussein Onn Malaysia, Batu Pahat, Johor, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2021 in International Journal of Antennas and Propagation
Verified
Journal Article
Open access
PDF file
Suhail Asghar QureshiSuhail Asghar Qureshi
Suhail Asghar Qureshi
Zuhairiah Zainal AbidinZuhairiah Zainal Abidin
Zuhairiah Zainal Abidin
AAADEL ASHYAP
ADEL ASHYAP
Huda Bin MajidHuda Bin Majid
Huda Bin Majid
MKMuhammad Ramlee Kamarudin
Muhammad Ramlee Kamarudin
JAMEL NEBHENJAMEL NEBHEN
JAMEL NEBHEN
The characterisation of the cooking oils presents a significant challenge due to minor changes in their dielectric behaviour. In this paper, a new metamaterial-based sensor incorporating a split-ring resonator (SRR) with a microstrip transmission line is presented to characterise cooking oils. The design demonstrates metamaterial characteristics of negative permittivity and permeability simultaneously at the resonance frequency. Furthermore, its operation in the range of millimetre-wave frequencies can further enhance its sensitivity, especially for liquid materials. The sensors novelty is the operation at millimetre-wave frequencies that offers a high shift in the transmission coefficient while operating at 30GHz. The sensors performance analysis is undertaken by using six MUTs with dielectric constants ranging from 0.126 to 4.47. The presented structure designed on 12×8mm2 Rogers substrate offers a sensitivity of 1.12GHz per unit change in dielectric constant. The phase's shift demonstrates a lower percentage error than the amplitude and linearly moves towards higher frequencies with the increase in dielectric constant and tangent loss of MUT. The designed sensor can be prominently useful for detecting liquids' chemical characteristics in chemistry and medicine fields.

29 June 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Suhail Asghar QureshiSuhail Asghar Qureshi
Suhail Asghar Qureshi
Zuhairiah Zainal AbidinZuhairiah Zainal Abidin
Zuhairiah Zainal Abidin
NEN. I. M. Elamin
N. I. M. Elamin
HMHuda A. Majid
Huda A. Majid
AAAdel Y. I. Ashyap
Adel Y. I. Ashyap
RAR. A. Abd-Alhameed
R. A. Abd-Alhameed
Millimetre-wave frequencies are promising for sensitive detection of glucose levels in the blood, where the temperature effect is insignificant. All these features provide the feasibility of continuous, portable, and accurate monitoring of glucose levels. This paper presents a metamaterial-inspired resonator comprising five split-rings to detect glucose levels at 24.9 GHz. The plexiglass case containing blood is modelled on the sensor’s surface and the structure is simulated for the glucose levels in blood from 50 mg/dl to 120 mg/dl. The novelty of the sensor is demonstrated by the capability to sense the normal glucose levels at millimetre-wave frequencies. The dielectric characteristics of the blood are modelled by using the Debye parameters. The proposed design can detect small changes in the dielectric properties of blood caused by varying glucose levels. The variation in the transmission coefficient for each glucose level tested in this study is determined by the quality factor and resonant frequency. The sensor presented can detect the change in the quality factor of transmission response up to 2.71/mg/dl. The sensor’s performance has also been tested to detect diabetic hyperosmolar syndrome. The sensor showed a linear shift in resonant frequency with the change in glucose levels, and an R2 of 0.9976 was obtained by applying regression analysis. Thus, the sensor can be used to monitor glucose in a normal range as well as at extreme levels.

5 March 2024 in Journal of Engineering and Applied Science
Verified
Journal Article
Open access
PDF file
MKMuhammad Hakimi Mustafa Kamal
Muhammad Hakimi Mustafa Kamal
Suhail Asghar QureshiSuhail Asghar Qureshi
Suhail Asghar Qureshi
Zuhairiah Zainal AbidinZuhairiah Zainal Abidin
Zuhairiah Zainal Abidin
HMHuda A. Majid
Huda A. Majid
CSChan Hwang See
Chan Hwang See
This study presents a biosensor working at a frequency of 3.5 GHz, which is designed as a square ring metamaterial resonator. This study aimed to evaluate the impact of blood amount on the metamaterial-based resonator sensor’s sensitivity. The structure was constructed using Rogers-RT5880 material, with an overall area of 85.71 mm × 85.71 mm2. The simulation of the design involved modelling the blood samples using Debye 1st-order equations. The empirical results observed a noticeable shift towards a lower frequency range in the response and changes in the magnitude, corresponding to an increase in the blood sample’s glucose concentration and thickness. Following this, the experiment was designed to corroborate the simulated results. The sensor achieved the highest sensitivity of 0.23 dB per 100 mg/dl change in glucose level when the thickness of blood was 0.1 mm. It was concluded from the results that the increase in the volume of blood increases the sensor’s sensitivity. However, a trade-off mark is necessary in which an optimum sensitivity is achieved with blood volume as minimum as possible so that a noninvasive biosensor can be designed.

25 November 2024 in IEEE Open Journal of Antennas and Propagation
Verified
Journal Article
Open access
Suhail Asghar QureshiSuhail Asghar Qureshi
Suhail Asghar Qureshi
MKMuhammad Ramlee Kamarudin
Muhammad Ramlee Kamarudin
YYYoshihide Yamada
Yoshihide Yamada
Muhammad Inam AbbasiMuhammad Inam Abbasi
Muhammad Inam Abbasi
Muhammad Hashim DahriMuhammad Hashim Dahri
Muhammad Hashim Dahri
NRNordin Ramli
Nordin Ramli
This work presents a graphene-based Reconfigurable Reflectarray Antenna (RRA) for 6G pointto-point communications. Unlike the conventional dimensions of less than λ/8 to act as the main resonant element, Graphene has been designed at λ/2 dimensions, which works as the phase-shifting element under a copper patch. Graphene’s chemical potential can be varied by applying DC biasing to array elements so that the reflection coefficient phase of the unit cells can be adjusted to form a collimated beam in a certain direction. An array of 977 elements with an aperture diameter of 15λ produced a collimated beam through two states of DC biasing to graphene, i.e. “On” and “Off”. Later, the beam steering performance of the designed RRA was analysed in the E-plane and H-plane. Furthermore, the effect of the focal length to diameter ratio (F/D) is also evaluated on the highest gain and the steering range. The highest gain of 25.6 dBi was obtained at 125 GHz with a beam steering range of ±30° with a gain loss of 3 dB when the F/D ratio was 0.9. However, the best beam steering range of ±45° with a gain loss of 3 dB was obtained when the F/D ratio was 1.1 and the highest gain of 23.25 dBi. Overall, the aperture efficiency was found to be 13% which is sufficient compared to conventional phase shifters at high frequencies. The 1-dB gain of the designed array was found to be 8.8%, 7.2% and 6.4% in the case of F/D ratio of 1.1, 1.0 and 0.9, respectively. Owing to the broadband operation from 122 GHz to 128 GHz, beam steering range, and aperture efficiency, the designed RRA shows the potential to be incorporated with reconfigurable intelligent surface (RIS)-based communications for 6G point-to-point communications.

12 August 2024 in International Journal of Integrated Engineering
Verified
Journal Article
Closed access
UMUniversiti Tun Hussein Onn Malaysia
Universiti Tun Hussein Onn Malaysia
Suhail Asghar QureshiSuhail Asghar Qureshi
Suhail Asghar Qureshi
ZAZuhairiah Zainal Abidin
Zuhairiah Zainal Abidin
MKMuhammad Ramlee Kamarudin
Muhammad Ramlee Kamarudin
NGNurul Bashirah Ghazali
Nurul Bashirah Ghazali
KEKuala Lumpur Evis
Kuala Lumpur Evis
Terahertz imaging offers significant potential for the early detection of skin cancer. This study introduces a metamaterial unit cell designed to operate in the terahertz (THz) band for non-invasive contact-based skin cancer detection. The sensor relies exclusively on the reflection coefficient response, providing high sensitivity to subtle changes in tissue properties without requiring complex signal processing. This simplicity may result in a cost-effective and straightforward implementation for early cancer detection.Simulations were conducted using 3D models representing various skin types, including normal skin, basal cell carcinoma (BCC), and melanoma. The dielectric characteristics of the samples were determined using the Double Debye model. The simulations revealed that the metamaterial design exhibited double negative material properties at a specific frequency of 1.15 THz. Upon skin contact and detection of malignancy, the reflection coefficient showed a shift toward lower frequencies. Notably, the melanoma sample exhibited the most significant shift, indicating a more severe form of cancer compared to BCC. Furthermore, it was observed that the difference in resonance frequencies between normal and malignant skin increased with the thickness of the sample. The sensor demonstrated high sensitivity in detecting cancer thickness, with a sensitivity of 9.25 GHz/μm for basal cell carcinoma (BCC) and 10.2 GHz/μm for melanoma. Furthermore, linear regression analysis revealed a robust correlation between the resonance frequency and the variation in cancer thickness, with R2 values of 0.9948 and 0.9947 for BCC and melanoma, respectively. These findings underscore the sensor's ability to detect skin cancer at its earliest stages, regardless of its severity.

27 September 2020
Verified
Conference Paper
Closed access
Suhail Asghar QureshiSuhail Asghar Qureshi
Suhail Asghar Qureshi
Zuhairiah Zainal AbidinZuhairiah Zainal Abidin
Zuhairiah Zainal Abidin
AAAdel Yahya Isa Ashyap
Adel Yahya Isa Ashyap
SDSamsul Haimi Dahlan
Samsul Haimi Dahlan
HMHuda A. Majid
Huda A. Majid
CSChan Hwang See
Chan Hwang See
A novel microwave technology-based biosensor operating at 36 GHz is developed for liquid-sensing properties for 5G applications. The metamaterial resonator in the designed biosensor consists of a single ring connected by two microstrip lines. The overall dimensions of the biosensor are 5×8 mm 2 . The simulated results demonstrate the resonant frequency drops as the MITT of higher permittivity value is introduced in place of the gap of the ring resonator. Therefore, the proposed metamaterial ring resonator can provide good sensitivity when sensing the MITT that are resonant in mm-W for 5G applications.