Fuzong Chang

Mr. Fuzong Chang

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2026 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
FCFuzong Chang
Fuzong Chang
YZYanxin Zhang
Yanxin Zhang
DQDexing Qian
Dexing Qian
TLTianshu Liu
Tianshu Liu
PMPaul William Mark Marshall
Paul William Mark Marshall
Chang, F, Zhang, Y, Qian, D, Liu, T, and Marshall, P. Increasing robotic horizontal resistance alters pair-specific intermuscular timing during sprint acceleration. J Strength Cond Res XX(X): 000–000, 2026—The purpose of this study was to determine whether increasing horizontal resistance alters pair-specific intermuscular timing and coupling during sprint acceleration. Fifteen university sprinters, 8 men and 7 women, performed maximal 30-m accelerations under 4 randomized robotic horizontal resistance conditions of 0, 5, 10, and 15% body weight (BW). Surface electromyography (EMG) was recorded from gluteus maximus (GMax), biceps femoris (BF), and gastrocnemius medialis (GM). All EMG channels shared a common acquisition time base. Gluteus maximus onset was used to define a common 300-ms analysis window, and normalized cross-correlation quantified temporal lag at peak correlation and coupling strength for the GMax-BF and GMax-GM pairs within a fixed ±100-ms lag range. Increasing resistance produced a greater GMax-GM lag at 15% than at 0% BW (paired mean difference 29.6 ms, 95% confidence interval: 14.1–45.1 ms; Holm-adjusted p = 0.006; Hedges' g = 0.90). No corrected GMax-BF pairwise contrast was identified, and coupling strength was unaffected by load in either muscle pair. For practitioners, resisted-sprint load selection may therefore influence the acute intermuscular timing demands imposed during acceleration, although the present results do not identify an optimal load or establish transfer to unresisted sprint performance.

11 November 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FCFuzong Chang
Fuzong Chang
YZYanxin Zhang
Yanxin Zhang
PMPaul William Mark Marshall
Paul William Mark Marshall
The validity of single-camera markerless analysis is often treated as a property of the system, although criterion agreement may also depend on how the same recording is analytically represented and what it is compared against. We tested these dependencies during early sprint acceleration using identical side-view recordings from 14 male athletes, including 12 amateur flag football players (140 trials). Direct two-dimensional MediaPipe and body-model-based Human Skeleton and Mesh Recovery (HSMR) outputs were compared with synchronised Vicon Plug-in Gait kinematics; MediaPipe was also compared with sagittally projected Vicon marker geometry, and video-derived events with force-platform definitions. MediaPipe hip and knee waveform correlations were 0.968–0.991, with root-mean-square errors (RMSEs) of 10.73–12.65°. Relative to MediaPipe, HSMR reduced the hip and knee RMSEs by 4.66° and 2.63° but increased the ankle RMSE by 9.33°. The MediaPipe RMSE was 1.46–2.79° lower against projected marker geometry than against Plug-in Gait, and the mean absolute error (MAE) was estimated to be 21.5% higher at the fifth than at the first analysis-window position across joints and viewing conditions. The video-event timing RMSE was 26.36–34.99 ms. Criterion agreement was therefore conditional on analytical workflow, comparator representation, and movement context rather than a fixed property of the recording; broad proximal waveform description was supported, whereas precise absolute joint angles and force-equivalent timing were not.