Accurate cross-modality brain image translation between magnetic resonance imaging (MRI) and computed tomography (CT) can enhance diagnosis and treatment planning by combining complementary structural and tissue information. This study develops a cycle-consistent generative adversarial network (CycleGAN)-based framework for unpaired MRI-to-CT and CT-to-MRI conversion, eliminating the need for paired datasets. Publicly available brain imaging datasets were preprocessed with intensity normalization and resizing, and the model was trained using a U-Net generator for anatomical preservation and a PatchGAN discriminator for texture fidelity. Quantitative evaluation using structural similarity index measure (SSIM), peak signal-to-noise ratio (PSNR), and mean absolute error (MAE) demonstrated that the proposed method outperforms baseline generative adversarial network (GAN) architectures, while expert radiologist reviews confirmed high structural consistency. The approach effectively maintains anatomical integrity and visual realism across modalities. This work’s novelty lies in optimizing CycleGAN architecture and hyperparameters for brain imaging translation, achieving superior performance without paired scans. The findings indicate potential for integration into clinical workflows, particularly in multimodal diagnosis and radiotherapy planning, offering a pathway to reduce scan redundancy and improve patient care. Unlike prior unpaired image-translation studies, this work introduces a U-Net–enhanced CycleGAN with optimized loss weighting and architecture tailoring for brain imaging, achieving improved structural fidelity and computational efficiency.
1 August 2026 in Asian Pacific Journal of Cancer Prevention
Objective: The primary objective of this study is to enhance the performance of cervical cancer classification by optimizing the Xception deep learning model using the Archer Fish Hunting Optimizer (AHO). The study aims to evaluate the effectiveness of the AHO-optimized Xception model in classifying cervical cytology images and to compare it against traditional CNN architectures. It also integrates Grad-CAM visualization to ensure model interpretability and to support explainable AI in clinical decision-making. Methods: A cervical cytology image dataset comprising four diagnostic classes High Squamous Intraepithelial Lesion (HSIL), Low Squamous Intraepithelial Lesion (LSIL), Negative for Intraepithelial Malignancy (NILM), and Squamous Cell Carcinoma (SCC) was used for model development. Preprocessing steps included image normalization and augmentation to improve generalization. Several deep learning models AlexNet, MobileNet V2, ResNet-50, Inception V3, and the standard Xception were trained and benchmarked. The AHO algorithm was applied to optimize the hyperparameters of the Xception model. Model performance was evaluated using metrics such as accuracy, precision, and AUC-ROC. Grad-CAM visualization was utilized to highlight image regions influencing classification decisions. Result: The AHO-optimized Xception model demonstrated superior classification performance, achieving 98.96% accuracy, 98.57% precision, and an AUC-ROC of 99.97%. It outperformed all baseline models in classification effectiveness. The Grad-CAM-based visualization provided valuable insights into the model’s focus areas, supporting interpretability and confidence in its predictions. Conclusion: The study establishes the efficacy of using the Archer Fish Hunting Optimizer for hyperparameter tuning in deep learning-based cervical cancer diagnosis. The AHO-optimized Xception model offers improved classification performance and robust explainability, making it a valuable tool for AI-assisted cervical cancer screening. Future research may explore hybrid metaheuristic strategies and their real-time deployment in clinical environments.
1 August 2026 in Bulletin of Electrical Engineering and Informatics
American sign language (ASL) is widely used for communication among the deaf and hard-of-hearing communities. This study aims to develop an optimized deep learning (DL) model for recognizing 36 static ASL gestures representing English alphabets (A–Z) and digits (0–9). A publicly available ASL dataset was used, and five convolutional neural network (CNN) architectures—AlexNet, GoogleNet, Inception V3, MobileNet, and ResNet50—were implemented as baselines. MobileNet was further optimized using the sailfish optimization (SFO) algorithm to fine-tune key hyperparameters and architectural settings. The models were evaluated using accuracy, macro precision, recall, F1-score, specificity, Cohen’s Kappa, Matthews correlation coefficient (MCC), balanced accuracy, Jaccard index, and error rate. The SFO-enhanced MobileNet achieved the highest performance, with 98.28% accuracy, 98.27% macro F1-score, 99.95% specificity, and a 1.72% error rate, outperforming all baselines across metrics. These results demonstrate that SFO optimization significantly improves MobileNet’s ability to classify ASL gestures accurately and efficiently. The proposed model’s high accuracy, robustness, and low inference time (22 ms) make it suitable for real-time sign language interpretation tools and assistive communication devices, supporting broader accessibility and inclusivity.
1 June 2026 in Bulletin of Electrical Engineering and Informatics
Globally, breast cancer is one of the reason for mortality among women and accurate automated diagnosis remains a critical research challenge. This research is used to improve breast cancer classification performance by optimizing deep learning (DL) model hyperparameters using a bio-inspired optimization technique. The osprey optimization algorithm (OOA) is applied to fine-tune the hyperparameters of the VGG16 convolutional neural network (CNN) for histopathological breast cancer image classification. The optimized model is evaluated using a curated dataset and compared with established DL architectures, including AlexNet, Xception, InceptionV3, and ResNet50. Performance is assessed using standard evaluation metrics such as accuracy, precision, recall, F1-score, specificity, AUC-ROC, Matthews correlation coefficient (MCC), log loss, and inference time. Experimental results indicate that the OOA-optimized VGG16 model achieves superior performance, with an accuracy of 97.7%, precision of 96.71%, recall of 97.79%, AUC-ROC of 99.92%, and MCC of 0.9449, while maintaining competitive computational efficiency. The results demonstrate that bio-inspired hyperparameter optimization significantly enhances classification reliability and diagnostic accuracy. In summary, integrating OOA optimization with the VGG16 architecture yields a dependable framework for breast cancer identification, making it a promising candidate for deployment in automated diagnostic support systems.
Accurate classification of electrocardiogram (ECG) signals is essential for early arrhythmia detection. This study compares the performance of unidirectional and bidirectional recurrent neural networks (RNN), specifically gated recurrent unit (GRU)-based architectures, for classifying ECG beats as normal or arrhythmic. ECG data were sourced from the MIT-BIH Arrhythmia Database using the WFDB toolkit. Each beat was segmented into a 128-sample window centered on the R-peak and labeled into two classes. To address severe class imbalance (6,279 normal vs. 43 arrhythmic beats), data augmentation techniques—jittering and scaling—were applied, resulting in a balanced dataset. Both models were trained under identical conditions, with evaluation based on accuracy, precision, recall, F1-score, and other statistical metrics. The unidirectional RNN achieved poor recall (9.0%) despite high precision, yielding an overall accuracy of 54.0%. In contrast, the bidirectional RNN significantly outperformed, achieving 98.17% accuracy, 98.39% precision, 97.92% recall, and a 98.16% F1-score. The results demonstrate that bidirectional temporal modeling provides substantial improvements in ECG classification, especially for detecting minority class arrhythmias. This study highlights the importance of both data augmentation and model architecture in developing effective deep learning solutions for real-time ECG analysis and clinical diagnostics.