Frank Tost

Prof. Dr. Frank Tost

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PSPatrick Schmidt
Patrick Schmidt
RKRobert Kempin
Robert Kempin
SLSönke Langner
Sönke Langner
ABAchim Beule
Achim Beule
SKStefan Kindler
Stefan Kindler
FTFrank Tost
Frank Tost
Exophthalmometry is a common examination in ophthalmology. For example it is relevant for diagnosis or follow-up of thyroid eye disease. However, exophthalmometry is affected by several factors such as ethnicity, sex and age. The purpose of this study was to determine the globe position by magnetic resonance imaging (MRI) and to investigate its correlates among the general Northeast German adult population. A total of 3030 subjects aged between 20 and 89 from the population-based Study of Health in Pomerania (SHIP) underwent a standardised whole-body MRI. Axial length and globe position were determined in axial T1-weighted images of the orbit. The image had to include the corneal apex as well as the optic nerve head. Study participants were excluded from imaging analysis if there was no plane available that included both structures. Further exclusion criterion was a lateral deviation of the subject’s viewing direction. Images with inadequate quality due to motion artefacts or other technical reasons were excluded as well. Globe position was defined as the perpendicular distance between the interzygomatic line and the posterior surface of the cornea (exophthalmometric value). The distance between the posterior surface of the cornea and the posterior pole of the eyeball, at the boundary with orbital fat, was defined as axial length. We used posterior surface of the cornea for our measurements, because it seemed to be less vulnerable for motion artefacts than the anterior one. Moreover body measurements including body mass index (BMI), waist and hip circumferences were determined. Associations between anthropometric measurements with exophthalmometric outcomes were analysed by linear regressions adjusted for age and stratified by sex. P-values <0.05 were considered as statistically significant. To assess intra-reader variability intra-class correlation coefficients (ICC) were computed for repeated measurements of the MRI scans of 25 subjects. After considering the exclusion criteria 1926 evaluable subjects remained. There was no significant difference between means of right and left eyes. The mean exophthalmometric value was significantly higher in men (16.5 +/- 2.2 mm) than in women (15.3 +/- 2.1 mm). The mean MRI-axial length was 23.4 +/- 0.8 mm for men and 22.8 +/- 0.9 mm for women. BMI, waist and hip circumferences were positively correlated with exophthalmometric value (p<0.001). Difference of mean MRI-based exophthalmometric value for obese subjects (BMI ≥30 kg/m2) and non-overweight (BMI <25 kg/m2) was 2.1 mm for men and 1.6 mm for women. ICC between 0.97 and 0.99 indicate excellent repeatability of our method. We conclude that MRI-based exophthalmometric values are positively correlated with BMI, waist- and hip-circumference among the general Northeast German adult population. This association is independent from age and axial length. Consequently bodyweight of patients should be regarded to interpret exophthalmometric values correctly. MRI-exophthalmometry seems to be a suitable method to determine globe position. Considering the large number of study participants, exophthalmometric values of our study could be used as comparative values for exophthalmometry of people of Western European descent in future.

24 December 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
Norbert HostenNorbert Hosten
Norbert Hosten
RBRobin Bülow
Robin Bülow
HVHenry Völzke
Henry Völzke
MDMartin Domin
Martin Domin
CSCarsten Oliver Schmidt
Carsten Oliver Schmidt
MKMarie-Luise Kromrey
Marie-Luise Kromrey
The Study of Health in Pomerania (SHIP), a population-based study from a rural state in northeastern Germany with a relatively poor life expectancy, supplemented its comprehensive examination program in 2008 with whole-body MR imaging at 1.5 T (SHIP-MR). We reviewed more than 100 publications that used the SHIP-MR data and analyzed which sequences already produced fruitful scientific outputs and which manuscripts have been referenced frequently. Upon reviewing the publications about imaging sequences, those that used T1-weighted structured imaging of the brain and a gradient-echo sequence for R2* mapping obtained the highest scientific output; regarding specific body parts examined, most scientific publications focused on MR sequences involving the brain and the (upper) abdomen. We conclude that population-based MR imaging in cohort studies should define more precise goals when allocating imaging time. In addition, quality control measures might include recording the number and impact of published work, preferably on a bi-annual basis and starting 2 years after initiation of the study. Structured teaching courses may enhance the desired output in areas that appear underrepresented.

1 January 2012 in Medical Science Monitor
Verified
Journal Article
Open access
PDF file
FTFrank Tost
Frank Tost
RKRamona Keiss
Ramona Keiss
RGRico Großjohann
Rico Großjohann
CJClemens Jürgens
Clemens Jürgens
JGJürgen Giebel
Jürgen Giebel
A large number of artificial tears is widely used to treat dry eye symptoms. To test the efficacy of these drugs independent of individual parameters in vitro models are required. As described previously, we employed a reproducible in vitro cell culture system to evaluate the desiccation protection capability of some artificial tears. In the present paper data is presented of another set of pharmaceutical agents. Conjunctival epithelial cell line Chang 1-5c-4 (series 1) and the corneal cell line 2.040 pRSV-T (series 2) were cultured under standard conditions. Confluent cells were wetted for 20 min with artificial tears (Arufil® Uno, Arufil®, Lacrimal®, Lacophthal® sine, Siccaprotect®, Tears Again®, Vidisept® EDO, Vistil®, Wet Comod®) or PBS as a control. After exposure to a constant air flow for 0, 15, 30 and 45 minutes respectively, cells were incubated with the vital dye alamarBlue. Subsequently, absorption of the oxidised form of the dye was assessed using an ELISA-Reader. Cell best survival rates in series 1 after 15 min were found for Lacrimal® (0.89), Wet Comod® (0.84) compared to PBS (0.66) and in series 2 for Vidisept® EDO (0.57) and Lacrimal® (0.56) compared to PBS (0.01). After 45 min highest survival was seen in series 1 for Lacrimal® (0.46) and Lacophthal® sine (0.36) compared to PBS (0.33) and in series 2 for Lacrimal® (−0.06) and Arufil (−0.16) compared to PBS (−0.23). Both cell lines tested showed different susceptibility towards desiccation and the artificial tears showed differences in preventing cells from desiccation.

22 December 2003 in Ophthalmologica
Verified
Journal Article
Closed access
FTFrank Tost
Frank Tost
JDJaques Darman
Jaques Darman
Stefan ClemensStefan Clemens
Stefan Clemens
Background: High-frequency B scan ultrasonography is a proven method for the assessment of anterior segment diseases. Only few studies have used sonography to examine the lacrimal drainage system. We examined the proximal lacrimal drainage system by high-resolution 20-MHz ultrasound to verify the possibility to identify intracanalicular lacrimal plugs. Methods: Eight patients who had received 12 lacrimal plug implants were examined by high-resolution ultrasound. A 20-MHz sector scanner was used for detection and localization of 2 types of intracanalicular plugs (Herrick® lacrimal silicone plug, Smart™ acrylic polymer plug) and 1 punctum plug. Ultrasound examinations were performed 1–24 months after plug placement. Cross-sections of the lacrimal canaliculi were obtained. Results: The various intracanalicular implants were successfully viewed using the 20-MHz ultrasound sector scanner. Intracanalicular plugs were located at the appropriate position as intended. The silicone plugs could be seen as areas of higher reflectivity. In contrast, acrylic polymer plugs were seen as low-reflective inner structures. In a longitudinal echogram, the interface between the acrylic polymer plug and the lacrimal canaliculus produced a strong acoustic impedance. In patients with an intracanalicular acrylic polymer plug, the caliber of the plug could be ascertained and the diameter measured. Conclusion: High-resolution ultrasound with a 20-MHz sector scanner is helpful in detecting intracanalicular plugs and is a valuable tool to assess the migration of lacrimal plugs through lacrimal canaliculi. A 20-MHz sector scanner can be used to identify and locate lacrimal plugs in the proximal drainage system even if biomicroscopic signs or clinical data are absent.

1 May 2006 in Der Ophthalmologe
Verified
Journal Article
Closed access
PDF file
RRR. Rath
R. Rath
JSJ. Stave
J. Stave
RGR. Guthoff
R. Guthoff
JGJ. Giebel
J. Giebel
FTFrank Tost
Frank Tost

1 September 2006 in Der Ophthalmologe
Verified
Journal Article
Closed access
PDF file
CJC. Jürgens
C. Jürgens
FTFrank Tost
Frank Tost