Jiuhong Jia

Dr. Jiuhong Jia


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Ultrasonics
Verified
Journal Article
Closed access
ZLZuoyu Liao
Zuoyu Liao
XZXin Zhang
Xin Zhang
TLTianyang Liu
Tianyang Liu
JJJiuhong Jia
Jiuhong Jia
STShan-Tung Tu
Shan-Tung Tu

6 May 2022 in International Journal of Pressure Vessels and Piping
Verified
Journal Article
Closed access
JSJiahe Song
Jiahe Song
DGDonghui Guo
Donghui Guo
JJJiuhong Jia
Jiuhong Jia
STShandong Tu
Shandong Tu

4 September 2017 in Materials
Verified
Journal Article
Open access
PDF file
JJJiuhong Jia
Jiuhong Jia
QWQiyue Wang
Qiyue Wang
ZLZuoyu Liao
Zuoyu Liao
YTYun Tu
Yun Tu
STShan-Tung Tu
Shan-Tung Tu
Guided wave technique could be a possible method for monitoring components working in high temperature above 350 °C. However, this would require the design of an appropriate waveguide bar to transmit the wave, so that its sensing part is not influenced by the high temperature. In the present study, the shape of waveguide bars is designed based on the analysis of wave source characteristics. The critical frequency-width and frequency-thickness products of waveguide bars are analyzed theoretically and numerically to transmit the zeroth shear horizontal wave SH0* in bars. The results show that waveguide bars can cut off all the other wave modes when their frequency-thickness products are smaller than the critical value fd*, and frequency-width products are not smaller than the critical value fw*. Six waveguide bars are designed and fabricated based on the design criteria, and an experiment system is set up to check their work performance. The testing results indicate that the wave signals of the SH0* mode propagate clearly in waveguide bars, and cut off all the other modes when the frequency-thickness products and frequency-width products of the bars meet the design criteria. It is also demonstrated that the dependency of the experimental group velocity of each waveguide bar on frequency is in good agreement with the numerical result. High-temperature experiments also validate the reliability of the designed waveguide bars. Therefore, the critical frequency-thickness product and frequency-width product can be the basis for the design of the waveguide bars.

13 November 2013 in Sensors
Verified
Journal Article
Open access
PDF file
HZHongcai Zhang
Hongcai Zhang
JJJiuhong Jia
Jiuhong Jia
NWNing Wang
Ning Wang
XHXiaoyin Hu
Xiaoyin Hu
STShan-Tung Tu
Shan-Tung Tu
ZWZhengdong Wang
Zhengdong Wang
To accurately detect deformation and extend the component life beyond the original design limits, structural safety monitoring techniques have attracted considerable attention in the power and process industries for decades. In this paper an on-line monitoring system for high temperature pipes in a power plant is developed. The extension-based sensing devices are amounted on straight pipes, T-Joints and elbows of a main steam pipeline. During on-site monitoring for more than two years, most of the sensors worked reliably and steadily. However, the direct strain gauge could not work for long periods because of the high temperature environment. Moreover, it is found that the installation and connection of the extensometers can have a significant influence on the measurement results. The on-line monitoring system has a good alarming function which is demonstrated by detecting a steam leakage of the header.

15 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
JJJiuhong Jia
Jiuhong Jia
ZLZuoyu Liao
Zuoyu Liao
XCXiaotao Cai
Xiaotao Cai
YTYun Tu
Yun Tu
STShan-Tung Tu
Shan-Tung Tu
The safety of critical pressure equipment in elevated temperature is increasingly important. Moreover, the on-line monitoring method is potentially useful to improve their safety. A waveguide bar system can enable monitoring of critical equipment working in elevated temperature using reliable ultrasonic technology. Among the waveguide bar system, the matching mechanism of the transducer and the waveguide bar is crucial to propagate the pure fundamental quasi-shear mode (shorten for SH0*) wave. In the present research, the loading line sources that can excite pure SH0* wave are investigated and the anti-plane shear loading source is selected. The critical values about the geometric dimensions of the junctions between the piezoelectric transducer and the waveguide bar are explored by simulation and experiments. On the condition that the excitation sources satisfy the critical values, the loading can be approximated to an anti-plane shear one to excite the pure SH0* wave. Some waveguide bar systems are designed based on the simulated critical values and some experiments at high temperature are carried out. The experimental results verify that the designed waveguide bar systems can excite the pure SH0* wave at elevated temperatures, which verify the reliability of the simulated critical results.

11 June 2024 in Measurement
Verified
Journal Article
Closed access
YGYiqing Gu
Yiqing Gu
MWMingyuan Wang
Mingyuan Wang
ZHZhaoqi Hou
Zhaoqi Hou
JJJiuhong Jia
Jiuhong Jia
STShan-Tung Tu
Shan-Tung Tu