The discharge characteristics of long air gaps are of great significance in the external insulation design of extra high voltage (EHV) and ultra high voltage (UHV) transmission lines. At present, the breakdown characteristics of air gaps are mainly investigated by repeated full-scale discharge tests. In order to reduce the costly experiment works, the influence of different tower structures on air gap breakdown voltage have been fully studied, and the tower structure coefficient Tg is proposed and calculated. Then a modified mathematical model is developed to calculate the 50 % discharge voltage of complicated bundle conductor-tower air gaps. The research results show that the 50% discharge voltages of different tower structures calculated by this models are in good agreement with the on-site test results. The maximum errors between the calculated and the test data is less than 6.3 %, which proves the feasibility of the proposed model for various engineering air gaps.
28 February 2020 in IET Generation, Transmission & Distribution
Air gap discharge voltage is the key parameter to determine the minimum approach distance for live working. In this study, a mathematical–physical model for predicting 50% discharge voltage of the transmission line air gaps considering the effect of live line worker is developed based on the continuous leader inception criterion. Also, the tower structure coefficient ST is proposed to represent the influence of various tower structures and ST is calculated by finite element method. Finally, the switching impulse discharge tests of the equipotential worker‐tower structure gaps are carried out on 750 kV transmission lines to verify the proposed model. The research results show that the errors between the calculation and experimental data are within ±4.03% which demonstrates the feasibility of discharge voltage prediction for complicated live working gaps. This model offers a possible way to determine the safety air gap distance for live working by analytical and numerical calculation rather than costly and time‐consuming experiments.
In order to solve the problem of three‐phase unbalance in low‐voltage distribution network caused by large‐scale access of distributed photovoltaic (PV) and electric vehicles (EVs), an active load control method of three‐phase unbalance in distribution network was presented in this study. Firstly, the active load regulation system was established and its implementation scheme was detailed. Then the active load regulation strategy using an integrated multi‐objective optimisation control algorithm was put forward and a solution method based on improved genetic algorithm was also proposed to realise optimal load distribution. Finally, the validity and feasibility of the proposed strategy was verified by simulation and the simulation results show that the active load regulation strategy can improve the consumptive ability of distributed PV and EVs, and can effectively reduce the three‐phase unbalance degree to improve the quality of power supply.