Jiwan Kim

Dr. Jiwan Kim

Advanced Materials Engineering, Kyonggi University, Suwon, Korea
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2012 in Nature
Verified
Journal Article
Closed access
YKYong-Hoon Kim
Yong-Hoon Kim
JHJae-Sang Heo
Jae-Sang Heo
TKTae-Hyeong Kim
Tae-Hyeong Kim
Sungjun ParkSungjun Park
Sungjun Park
MYMyung-Han Yoon
Myung-Han Yoon
SPSung Kyu Park
Sung Kyu Park

18 December 2014 in Chemistry of Materials
Verified
Journal Article
Closed access
JKJong-Hoon Kim
Jong-Hoon Kim
CHChang-Yeol Han
Chang-Yeol Han
KLKi-Heon Lee
Ki-Heon Lee
KAKi-Seok An
Ki-Seok An
WSWooseok Song
Wooseok Song
Heesun YangHeesun Yang
Heesun Yang

31 March 2015 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KOKi-Hun Ok
Ki-Hun Ok
Jiwan KimJiwan Kim
Jiwan Kim
SPSo-Ra Park
So-Ra Park
YKYoungmin Kim
Youngmin Kim
CLChan-Jae Lee
Chan-Jae Lee
JKJong-Woong Kim
Jong-Woong Kim
A smooth, ultra-flexible and transparent electrode was developed from silver nanowires (AgNWs) embedded in a colorless polyimide (cPI) by utilizing an inverted film-processing method. The resulting AgNW-cPI composite electrode had a transparency of >80%, a low sheet resistance of 8 Ω/□ and ultra-smooth surfaces comparable to glass. Leveraging the robust mechanical properties and flexibility of cPI, the thickness of the composite film was reduced to less than 10 μm, which is conducive to extreme flexibility. This film exhibited mechanical durability, for both outward and inward bending tests, up to a bending radius of 30 μm, while maintaining its electrical performance under cyclic bending (bending radius: 500 μm) for 100,000 iterations. Phosphorescent, blue organic light-emitting diodes (OLEDs) were fabricated using these composites as bottom electrodes (anodes). Hole-injection was poor, because AgNWs were largely buried beneath the composite's surface. Thus, we used a simple plasma treatment to remove the thin cPI layer overlaying the nanowires without introducing other conductive materials. As a result, we were able to finely control the flexible OLEDs' electroluminescent properties using the enlarged conductive pathways. The fabricated flexible devices showed only slight performance reductions of <3% even after repeated foldings with a 30 μm bending radius.

6 April 2016 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
HKHee Yeon Kim
Hee Yeon Kim
YPYu Jin Park
Yu Jin Park
Jiwan KimJiwan Kim
Jiwan Kim
CHChul Jong Han
Chul Jong Han
JLJeongno Lee
Jeongno Lee
MOMin Suk Oh
Min Suk Oh

1 January 2014 in Organic Electronics
Verified
Journal Article
Closed access
CIChristian Ippen
Christian Ippen
TGTonino Greco
Tonino Greco
YKYohan Kim
Yohan Kim
Jiwan KimJiwan Kim
Jiwan Kim
MOMin Suk Oh
Min Suk Oh
AWArmin Wedel
Armin Wedel

1 October 2011 in Clinical Eeg and Neuroscience
Verified
Journal Article
Open access
PDF file
STSanitta Thongpang
Sanitta Thongpang
TRThomas J. Richner
Thomas J. Richner
SBSarah K. Brodnick
Sarah K. Brodnick
ASAmelia Schendel
Amelia Schendel
Jiwan KimJiwan Kim
Jiwan Kim
JWJustin C. Williams
Justin C. Williams
Over the past decade, electrocorticography (ECoG) has been used for a wide set of clinical and experimental applications. Recently, there have been efforts in the clinic to adapt traditional ECoG arrays to include smaller recording contacts and spacing. These devices, which may be collectively called “micro-ECoG” arrays, are loosely defined as intercranial devices that record brain electrical activity on the submillimeter scale. An extensible 3D-platform of thin film flexible microscale ECoG arrays appropriate for Brain-Computer Interface (BCI) application, as well as monitoring epileptic activity, is presented. The designs utilize flexible film electrodes to keep the array in place without applying significant pressure to the brain and to enable radial subcranial deployment of multiple electrodes from a single craniotomy. Deployment techniques were tested in non-human primates, and stimulus-evoked activity and spontaneous epileptic activity were recorded. Further tests in BCI and epilepsy applications will make the electrode platform ready for initial human testing.