The ocular surface system, essential for maintaining visual function, is highly susceptible to a range of ocular surface diseases (OSDs) that significantly impair patients’ quality of life. Current treatments for OSDs often face limitations including low bioavailability, A lack of targeted delivery, and an inadequate capacity to fully address the complex pathophysiology involving inflammation, oxidative stress, and impaired tissue repair. In recent years, exosomes have emerged as promising cell-free therapeutic platforms for OSDs. This review evaluates their therapeutic potential across the OSD spectrum, focusing on three key aspects: mechanisms—modulation of inflammation, oxidative stress, and tissue repair via bioactive cargo; applications—preclinical therapeutic effects in dry eye disease, corneal injury, keratitis, and transplant rejection; and optimization strategies—engineering approaches and biomaterial integration to enhance stability, targeting, and ocular retention. We also discuss critical challenges in standardization, scalable production, and clinical translation, highlighting future directions for exosome-based OSD therapies.
Background/Objectives: To compare preoperative clinical and biometric characteristics between primary angle-closure disease (PACD) eyes with intraoperatively identified zonulopathy and their fellow eyes, and to explore interdevice measurement differences. Methods: This single-center paired-eye study included 57 patients with PACD undergoing bilateral cataract surgery and unilateral intraoperatively identified zonulopathy. Preoperative measurements were obtained using IOLMaster, Pentacam, and ultrasound biomicroscopy (UBM). Paired outcomes were compared using Wilcoxon signed-rank or exact McNemar tests, with Benjamini–Hochberg correction applied separately to clinical and biometric comparisons. Results: Eyes with zonulopathy more frequently had primary angle-closure glaucoma and previous acute angle-closure (AAC) attacks, greater angle-closure extent, and more severe mean deviation-based visual-field loss. These eyes had shallower corrected IOLMaster anterior chamber depth (ACD; 1.50 ± 0.40 versus 1.82 ± 0.35 mm), lower lens position (4.03 ± 0.33 versus 4.37 ± 0.28 mm), and smaller anterior chamber volume (59.9 ± 24.0 versus 75.4 ± 22.8 mm³; all q < 0.001). UBM minus IOLMaster ACD, UBM minus Pentacam ACD, and Pentacam minus UBM pupil diameter differed significantly between paired eyes (q = 0.002, 0.017, and 0.023, respectively). Conclusions: PACD eyes with occult zonulopathy showed a shallower anterior chamber, lower lens position, smaller anterior chamber volume, and greater interdevice differences in selected ACD and pupil measurements. These exploratory associations require validation before their use for preoperative identification of zonulopathy.