Yuwen Zeng

Dr. Yuwen Zeng

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
YZYuwen Zeng
Yuwen Zeng
XZXiaoyong Zhang
Xiaoyong Zhang
YKYusuke Kawasumi
Yusuke Kawasumi
AUAkihito Usui
Akihito Usui
KIKei Ichiji
Kei Ichiji
NHNoriyasu Homma
Noriyasu Homma
It is challenging to diagnose drowning in autopsy even with the help of post-mortem multi-slice computed tomography (MSCT) due to the complex pathophysiology and the shortage of forensic specialists equipped with radiology knowledge. Therefore, a computer-aided diagnosis (CAD) system was developed to help with diagnosis. Most deep learning-based CAD systems only utilize 2D information, which is proper for 2D data such as chest X-ray images. However, 3D information should also be considered for 3D data like CT. Conventional 3D methods require a huge amount of data and computational cost when using 3D methods. In this paper, we proposed a 2.5D method that converts 3D data into 2D images to train 2D deep learning models for drowning diagnosis. The key point of this 2.5D method is that it uses a subset to represent the whole case, covering this case as much as possible while avoiding other repetitive information. To evaluate the effectiveness of the proposed method, conventional 2D, previous 2.5D, and 3D deep learning-based methods were tested using an MSCT dataset obtained from Tohoku university. Then, to provide explainable diagnosis results, a visualization method called Gradient-weighted Class Activation Mapping was employed to visualize features relevant to drowning in CT images. Results on drowning diagnosis showed that our proposed method achieved the best performance compared to other 2D, 2.5D, and 3D methods. The visual assessment also demonstrated that our method could find the saliency regions corresponding to drowning.

11 April 2025 in Journal of Voice
Verified
Journal Article
Closed access
JVJan Vrba
Jan Vrba
JSJakub Steinbach
Jakub Steinbach
TJTomáš Jirsa
Tomáš Jirsa
Laura VerdeLaura Verde
Laura Verde
RFRoberta De Fazio
Roberta De Fazio
NHNoriyasu Homma
Noriyasu Homma

19 December 2025 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Open access
KTKengo Takahashi
Kengo Takahashi
YZYuwen Zeng
Yuwen Zeng
ZZZhang Zhang
Zhang Zhang
KIKei Ichiji
Kei Ichiji
TUTakuma Usuzaki
Takuma Usuzaki
NHNoriyasu Homma
Noriyasu Homma
Recent breast cancer research has investigated shape-based attention guidance in Vision Transformer (ViT) models, focusing on anatomical structures and the heterogeneity surrounding tumors. However, few studies have clarified the optimal transformer encoder layer stage for applying attention guidance. Our study aimed to evaluate the effectiveness of shape-guidance strategies by varying the combinations of encoder layers that guide attention to breast structures and by comparing the proposed models with conventional models. For the shape-guidance strategy, we applied breast masks to the attention mechanism to emphasize spatial dependencies and enhance the learning of positional relationships within breast anatomy. We then compared the representative models—Masked Transformer models that demonstrated the best performance across layer combinations—with the conventional ResNet50, ViT, and SwinT V2. In our study, a total of 2,436 publicly available mammography images from the Chinese Mammography Database via The Cancer Imaging Archive were analyzed. Three-fold cross-validation was employed, with a patient-wise split of 70% for training and 30% for validation. Model performance on differentiating breast cancer from non-cancer images was assessed by the area under the receiver-operating characteristic curve (AUROC). The results showed that applying masks at the Shallow and Deep stages gave the highest AUROC for Masked ViT. The Masked ViT achieved an AUROC of 0.885 [95% confidence interval: 0.849–0.918], a sensitivity of 0.876, and a specificity of 0.802, outperforming all other conventional models. These results indicate that incorporating mask guidance into particular Transformer encoders promotes representation learning, highlighting their potential as decision-support tools in breast cancer diagnosis.

9 February 2024 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Open access
PDF file
YZYuwen Zeng
Yuwen Zeng
XZXiaoyong Zhang
Xiaoyong Zhang
JWJiaoyang Wang
Jiaoyang Wang
AUAkihito Usui
Akihito Usui
KIKei Ichiji
Kei Ichiji
NHNoriyasu Homma
Noriyasu Homma
Drowning diagnosis is a complicated process in the autopsy, even with the assistance of autopsy imaging and the on-site information from where the body was found. Previous studies have developed well-performed deep learning (DL) models for drowning diagnosis. However, the validity of the DL models was not assessed, raising doubts about whether the learned features accurately represented the medical findings observed by human experts. In this paper, we assessed the medical validity of DL models that had achieved high classification performance for drowning diagnosis. This retrospective study included autopsy cases aged 8–91 years who underwent postmortem computed tomography between 2012 and 2021 (153 drowning and 160 non-drowning cases). We first trained three deep learning models from a previous work and generated saliency maps that highlight important features in the input. To assess the validity of models, pixel-level annotations were created by four radiological technologists and further quantitatively compared with the saliency maps. All the three models demonstrated high classification performance with areas under the receiver operating characteristic curves of 0.94, 0.97, and 0.98, respectively. On the other hand, the assessment results revealed unexpected inconsistency between annotations and models’ saliency maps. In fact, each model had, respectively, around 30%, 40%, and 80% of irrelevant areas in the saliency maps, suggesting the predictions of the DL models might be unreliable. The result alerts us in the careful assessment of DL tools, even those with high classification performance.

21 September 2025
Verified
Book Chapter
Closed access
PDF file
HLHaoyang Liu
Haoyang Liu
YZYuwen Zeng
Yuwen Zeng
XZXiaoyong Zhang
Xiaoyong Zhang
WZWentong Zhou
Wentong Zhou
ANArata Nagai
Arata Nagai
NHNoriyasu Homma
Noriyasu Homma

27 August 2025 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
JWJiaoyang Wang
Jiaoyang Wang
KIKei Ichiji
Kei Ichiji
YZYuwen Zeng
Yuwen Zeng
XZXiaoyong Zhang
Xiaoyong Zhang
YTYoshihiro Takai
Yoshihiro Takai
NHNoriyasu Homma
Noriyasu Homma
Markerless tumor tracking in x-ray fluoroscopic images is an important technique for achieving precise dose delivery for moving lung tumors during radiation therapy. However, accurate tumor tracking is challenging due to the poor visibility of the target tumor overlapped by other organs such as rib bones. Dual-energy (DE) x-ray fluoroscopy can enhance tracking accuracy with improved tumor visibility by suppressing bones. However, DE x-ray imaging requires special hardware, limiting its clinical use. This study presents a deep learning-based DE subtraction (DES) synthesis method to avoid hardware limitations and enhance tracking accuracy. The proposed method employs a residual U-Net model trained on a simulated DES dataset from a digital phantom to synthesize DES from single-energy (SE) fluoroscopy. Experimental results using a digital phantom showed quantitative evaluation results of synthesis quality. Also, experimental results using clinical SE fluoroscopic images of ten lung cancer patients showed improved tumor tracking accuracy using synthesized DES images, reducing errors from 1.80 to 1.68 mm on average. The tracking success rate within a 25% movement range increased from 50.2% (SE) to 54.9% (DES). These findings indicate the feasibility of deep learning-based DES synthesis for markerless tumor tracking, offering a potential alternative to hardware-dependent DE imaging. Graphical The U-Net model was first trained on simulated single-energy and dual-energy subtraction image pairs, then applied to synthesize DES from clinical X-ray images for improving tumor tracking