Matjaž Ramšak

Dr. Matjaž Ramšak


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in Journal of Drug Delivery Science and Technology
Verified
Journal Article
Closed access
Jure RavnikJure Ravnik
Jure Ravnik
IGI. Golobič
I. Golobič
ASA. Sitar
A. Sitar
MAM. Avanzo
M. Avanzo
ŠIŠ. Irman
Š. Irman
MHMatjaž Hriberšek
Matjaž Hriberšek

1 February 2021 in European Journal of Pharmaceutics and Biopharmaceutics
Verified
Journal Article
Closed access
Jure RavnikJure Ravnik
Jure Ravnik
MRMatjaž Ramšak
Matjaž Ramšak
MZMatej Zadravec
Matej Zadravec
BKBlaz Kamenik
Blaz Kamenik
MHMatjaž Hriberšek
Matjaž Hriberšek

7 September 2022 in Engineering Analysis with Boundary Elements
Verified
Journal Article
Closed access
MRMatjaž Ramšak
Matjaž Ramšak

7 December 2023 in Journal of Pharmaceutical Sciences
Verified
Journal Article
Open access
MRMatjaž Ramšak
Matjaž Ramšak
MHMatjaž Hriberšek
Matjaž Hriberšek
The vial wall thermal conductivity and thickness effect on freeze-drying speed is simulated. A 2D axisymmetric numerical simulation of Mannitol freeze-drying is employed using the boundary element method. The originality of the presented approach lies in the simulation of heat transfer in the vial walls as an additional computational domain in contrast to the typical methodology without a vial wall. The numerical model was validated using our measurements and the measurements from the literature. Increasing the glass vial thickness from 1 mm to 2 mm has been found as the major factor in primary drying time, increasing the gravimetrical Kv up to 20 % for all the simulated chamber pressures. The effect of thermal conductivity was simulated using a polymer and aluminium vial replacing the standard glass vial of the same thickness. The polymer vial's decreased Kv value is 5.6 % at a low chamber pressure of 50 mTorr, and 12.2 % at 400 mTorr, which is in excellent agreement with the experiment. Using higher conductivity materials, for example, aluminium, only 3.7 % and 2.3 % Kv increase were computed for low and high chamber pressures respectively. (c) 2023 The Authors. Published by Elsevier Inc. on behalf of American Pharmacists Association. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)

1 January 2017 in Thermal Science
Verified
Journal Article
Open access
PDF file
MZMatej Zadravec
Matej Zadravec
MRMatjaž Ramšak
Matjaž Ramšak
Jure RavnikJure Ravnik
Jure Ravnik
MHMatjaž Hriberšek
Matjaž Hriberšek
JSJernej Slanovec
Jernej Slanovec
Efficiency of cooling fins inside of a LED fog lamp is studied using CFD. Diffusion in heat sink, natural convection and radiation are the main principles of the simulated heat transfer. The Navier-Stokes equations were solved by the CFD code, including Monte Carlo radiation model and no additional turbulence model was needed. The numerical simulation is tested using the existing lamp geometry and temperature measurements. The agreement is excellent inside of few degrees at all measured points. The main objective of the article is to determine the cooling effect of various heat sink parts. Based on performed simulations, some heat sink parts are found to be very ineffective. The geometry and heat sink modifications are proposed. While radiation influence is significant, compressible effects are found to be minor.

8 February 2019 in Engineering Analysis with Boundary Elements
Verified
Journal Article
Closed access
MRMatjaž Ramšak
Matjaž Ramšak