This study applies, tests, and compares comprehensive surrogate-based optimization techniques to optimize the performance of polymer electrolyte membrane fuel cells (PEMFCs). Moreover, parametric cases considering four important design variables, i.e., gas diffusion layer thickness ( ), channel depth ( ), channel width ( ), and land width ( ), are defined using the latin hypercube sampling technique under reasonable constraint conditions. Multidimensional, two-phase PEMFC model simulations are performed to generate the training and test data under these design conditions. Three famous surrogate models, i.e., response surface approximation (RSA), radial basis neural network (RBNN), and kriging (KRG), are employed to construct objective functions for the PEMFC cell voltages operating in the galvanostatic mode, and their accuracies are tested and compared using root mean square error and adjusted R-square. The surrogates are then linked to stochastic optimization algorithms, i.e., genetic algorithm and particle swarm optimization, to determine the optimal design points. A comparative study of these surrogates reveals that the KRG model outperforms the RBNN and RSA models in terms of prediction capability. Furthermore, the PEMFC model simulations at the optimal design points clearly demonstrate that performance improvements of around 56–69 mV at 2.0 A cm−2 are achieved with the optimum design values compared to typical PEMFC design conditions.
An absorption chiller model for tri-generation (combined cooling, heating, and power) is developed and incorporated with the high temperature- (HT-) proton exchange membrane fuel cell (PEMFC) system model that was developed in our previous study. We employ a commercially available flow simulator, Aspen HYSYS, for solving the energy and mass balances of various system components, including an HT-PEMFC stack that is based on a phosphoric acid-doped PBI membrane, natural gas-fueled reformer, LiBr-H2O absorption chiller, balance of plant (BOP) components, and heat exchangers. Since the system’s operating strategy for tri-generation must be changed, depending on cooling or heating loads, a major focus of this study is to analyze system performance and efficiency under different requirements of electricity generation, cooling, and heating conditions. The system simulation results revealed that high-current fuel-cell operation is essential in raising the cooling capacity, but the overall system efficiency is slightly reduced as a result. Using a lower fuel-air ratio for the burner in the reforming module is one alternative that can minimize the reduction in the overall system efficiency under high-current fuel-cell operation and large cooling-capacity modes.
In this study, we analyze the impacts of various stack configurations of a solid oxide electrolysis cell (SOEC) that includes U-type and Z-type stack structures as well as co-flow and counter-flow configurations. The primary focus of this study is to analyze the impact of these SOEC stack configurations on the temperature distribution within the stack and the temperature variations of key components. Furthermore, by predicting the thermal stress and thermal deformation of individual SOEC components, the study can provide design guidelines for enhancing the durability of the SOEC stack. Among various SOEC stack configurations, the counter-flow design outperformed others in temperature uniformity and component temperature variation. The Z-type stack structure slightly surpassed the U-type in flow uniformity, while both had a minimal influence on thermal management. Besides conventional flow-field configurations, such as the parallel flow field, we introduce a metal-foam-based flow-field design and analyze the effects of using metal foam to ensure flow uniformity within the stack and achieve temperature uniformity. The metal foam design has a lower average temperature (2–5 °C) and ∆T (4–7 °C) compared to the parallel flow field in each cell, but this improvement is accompanied by a substantial pressure-drop: 2359.3 Pa for vapor flow (11.7 times higher) and 4409.0 Pa for air flow (4.6 times higher). Additionally, structural analysis was performed using CFD temperature data. The co-flow configuration induced higher thermal stress at the front of the stack, whereas the counter-flow configuration mitigated thermal stress in the front cells. The metal foam structure consistently demonstrated a reduction in thermal stress across all cells by about 1 MPa, highlighting its potential to alleviate thermal stress in SOEC stacks. This study presents a novel CFD analysis approach for a 10-cell SOEC stack, enabling the development of an optimized stack design with improved heat and flow distribution. The integrated CFD–FEM analysis provides reliable thermal stress data that elucidates the correlation between temperature and stress distributions within the stack.